РЗЛ-05.МХ relay protection, automation and monitoring devices for 6-35 kV substations and feeders
The РЗЛ-05.МХ series provides overcurrent protection, automation, signalling, fault recording, diagnostics and circuit breaker control for 6-35 kV feeders. Ten versions are offered, РЗЛ-05.М4 to М36, with recessed (У) or protruding (В) mounting and an operating temperature of -40...+60 °C.
- Network voltage
- 6-35 kV
- Operating supply
- DC, AC, rectified, including from current circuits
- Operating voltages
- 220 V, 110 V, 24 V
- Protections
- Overcurrent, earth fault, auto-reclosing, arc protection with fibre-optic sensors
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The РЗЛ-05.МХ microprocessor devices carry out overcurrent protection, automation, signalling, recording of fault parameters, diagnostics and circuit breaker control on feeders of 6-35 kV. They protect overhead and cable lines in substations and distribution points, as well as section breakers. The devices are installed in the relay compartments of КСО, КРУ and КРУН switchgear, and the hardware and logic configuration is a light one.
The operating supply may be DC, AC or rectified, including a supply from the current circuits, that is, from current transformers. Protection covers phase-to-phase and earth faults, auto-reclosing and arc protection with fibre-optic sensors. Communication uses RS-485, USB and Ethernet interfaces with Modbus RTU and Modbus TCP protocols, and the devices integrate into SCADA systems. A digital oscillograph, an event log and an OLED display with local control buttons are fitted, and all inputs and outputs are galvanically isolated.
The series has ten versions: РЗЛ-05.М4, М5, М6, М14, М15, М16, М25, М26, М35 and М36. They differ in whether they have a supply from a current source, de-shunting of the breaker trip coils, fibre-optic inputs for arc protection and an Ethernet port. Each version is made with recessed (У) or protruding (В) mounting. Operating voltages are 220 V, 110 V and 24 V.
Dimensions are 220x220x100 mm and the operating temperature range is -40...+60 °C.
Technical specifications
| Network voltage | 6-35 kV |
|---|---|
| Operating supply | DC, AC, rectified, including from current circuits |
| Operating voltages | 220 V, 110 V, 24 V |
| Protections | Overcurrent, earth fault, auto-reclosing, arc protection with fibre-optic sensors |
| Interfaces | RS-485, Ethernet, USB |
| Protocols | Modbus RTU, Modbus TCP |
| Recording | Digital oscillograph, event log |
| Display | OLED, local control buttons |
| Mounting | Recessed (У), protruding (В) |
| Dimensions | 220х220х100 mm |
| Operating temperature | -40...+60 °C |
Part numbers
Show all part numbers (12)
РЗЛ-05.М4-У, РЗЛ-05.М5-У, РЗЛ-05.М6-У, РЗЛ-05.М14-У, РЗЛ-05.М15-У, РЗЛ-05.М16-У, РЗЛ-05.М16-В, РЗЛ-05.М25-У, РЗЛ-05.М26-У, РЗЛ-05.М35-У, РЗЛ-05.М36-У, РЗЛ-05.М36-В
How it compares with similar models
| Parameter | РЗЛ-05.МХ relay protection, automation and monitoring devices for 6-35 kV substations and feeders | РЗЛ-05.ВХ protection, automation and monitoring unit for 6-154 kV connections, 12 versions | RZL-100 protection, automation and control device for 6-20 kV substations and feeders | RZL-400 protection, automation and control terminal for 6-35 kV substations and feeders |
|---|---|---|---|---|
| Interfaces | RS-485, Ethernet, USB | RS-485, Ethernet, USB | — | RS-485, Ethernet RJ-45, USB |
| Protocols | Modbus RTU, Modbus TCP | MODBUS RTU, MODBUS TCP | Modbus RTU, Modbus TCP | Modbus RTU/TCP, IEC 60870-5-101/103/104 |
| Display | OLED, local control buttons | — | OLED | OLED |
| Dimensions | 220х220х100 mm | — | 220х207х80.5 mm | 220х207х80.5 mm |
| Operating temperature | -40...+60 °C | −40…+60 °C | -40°C...+60°C | -40°C...+60°C |
European equivalents
BELplus OZE, PROTECTA DTIVA, IDF / IDV / IDX transformer differential protection terminal, SMPR / SMPR-2 / SMPR ETH multifunction protection terminals for MV feeders (current, voltage, power, directional protection)
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
РЗЛ-05.МХ relay protection, automation and monitoring devices for 6-35 kV substations and feeders. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which feeders do the РЗЛ-05.МХ devices protect?
Overhead and cable lines and section breakers of 6-35 kV in the relay compartments of КСО, КРУ and КРУН.
How many versions does the РЗЛ-05.МХ series have?
Ten, from РЗЛ-05.М4 to РЗЛ-05.М36, each with recessed (У) or protruding (В) mounting.
Which protocols and interfaces are available?
Modbus RTU and Modbus TCP protocols with RS-485, Ethernet and USB interfaces, depending on the version.