РЗЛ-05.АХ protection unit with extended configuration for 6-154 kV connections, 10 versions

The РЗЛ-05.АХ, with an extended hardware and logic configuration, provides protection, automation, signalling and breaker control for 6-154 kV connections. It has 8 analogue inputs, 20 discrete inputs, 17 relays and 10 versions.

Application
protection, automation and breaker control of 6-154 kV connections
Auxiliary supply voltage
220 V (110 V)
Analogue inputs
8
Discrete inputs
20

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The РЗЛ-05.АХ series are microprocessor protection and automation units with an extended hardware and logic configuration, made for the connections of 6-154 kV switchgear. They cover protection, automation, signalling, fault recording, diagnostics and breaker control. Typical uses are overhead and cable lines, incomer and section breakers, and backup protection of transformers.

Measuring inputs are 8 analogue channels and 1 temperature sensor input. The unit has 20 discrete inputs and 17 output relays. Other functions are a digital oscillograph, an event log, freely programmable logic (СПЛ), SCADA integration and integrated arc protection with fibre-optic sensors. Interfaces are RS-485, Ethernet and USB, with MODBUS RTU and MODBUS TCP.

The ten versions РЗЛ-05.А1…А6 and А11…А14 all use a 220 V (110 V) auxiliary supply. Backup supply from CT circuits is in А2, А4, А5, А6, А12 and А14. De-shunting of breaker current solenoids is in А5 and А6. Three fibre-optic sensor inputs are in А3, А4, А6, А13 and А14. The Ethernet port is in versions А11…А14.

The РЗЛ-05.А5 measures 265 × 240 × 195 mm and the РЗЛ-05.А6 measures 280 × 260 × 195 mm. Mounting is in a panel or cabinet. Operating temperature is −40 to +60 °C.

Free programmable logic is written with external circuits disconnected. Before settings or parameters are changed, the connection is taken out and left for at least two minutes. After storage without power, the unit is kept energised for at least 1 hour to charge its internal battery.

Technical specifications

Applicationprotection, automation and breaker control of 6-154 kV connections
Auxiliary supply voltage220 V (110 V)
Analogue inputs8
Discrete inputs20
Output relays17
Backup supply from CT circuitsА2, А4, А5, А6, А12, А14
De-shunting of current solenoidsА5, А6
Fibre-optic sensor inputs3 (А3, А4, А6, А13, А14)
Ethernet portА11…А14
InterfacesRS-485, Ethernet, USB
ProtocolsMODBUS RTU, MODBUS TCP
РЗЛ-05.А5 dimensions265 × 240 × 195 mm
РЗЛ-05.А6 dimensions280 × 260 × 195 mm
Operating temperature−40…+60 °C

Part numbers

Show all part numbers (10)

РЗЛ-05.А1, РЗЛ-05.А2, РЗЛ-05.А3, РЗЛ-05.А4, РЗЛ-05.А5, РЗЛ-05.А6, РЗЛ-05.А11, РЗЛ-05.А12, РЗЛ-05.А13, РЗЛ-05.А14

How it compares with similar models

ParameterРЗЛ-05.АХ protection unit with extended configuration for 6-154 kV connections, 10 versionsРЗЛ-05.ВХ protection, automation and monitoring unit for 6-154 kV connections, 12 versionsРЗЛ-05.ФХ protection, automation and monitoring unit for 6-154 kV connections, 6 versionsРЗЛ-05.ТН protection and automation unit for 110-35-10(6) kV voltage transformers
Applicationprotection, automation and breaker control of 6-154 kV connectionsprotection, automation and breaker control of 6-154 kV connectionsprotection, automation and breaker control of 6-154 kV connectionsprotection and automation of a 110-35-10(6) kV voltage transformer
Analogue inputs885 (IA, IB, IC, 3I0, 3U0)7 (UA, UB, UC, 3U0, UТСН1, UТСН2, UТН1)
Discrete inputs2012 (3 dry-contact)12 (3 dry-contact)12 (3 dry-contact)
Output relays17131313 (4 with changeover group, 1 bistable К7, 1 KWD)
Backup supply from CT circuitsА2, А4, А5, А6, А12, А14В2, В4, В5, В6, В12, В14, В15, В16Ф2, Ф4, Ф5, Ф6—
De-shunting of current solenoidsА5, А6В5, В6, В15, В16Ф5, Ф6—

European equivalents

BELplus OZE, IDF / IDV / IDX transformer differential protection terminal, PROTECTA DTIVA, DZ9

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

РЗЛ-05.АХ protection unit with extended configuration for 6-154 kV connections, 10 versions. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the РЗЛ-05.АХ differ from the РЗЛ-05.ВХ?

The РЗЛ-05.АХ has an extended hardware and logic configuration, with 20 discrete inputs and 17 relays against 12 and 13 on the ВХ.

Which versions have backup supply from CT circuits?

А2, А4, А5, А6, А12 and А14. De-shunting is in А5 and А6, and fibre-optic inputs are in А3, А4, А6, А13 and А14.

Which interfaces and protocols are supported?

RS-485, Ethernet (in versions А11…А14) and USB, with MODBUS RTU and MODBUS TCP.