РЗЛ-05.АЕ protection and automation unit for 6–35 kV feeders, 24 output relays
The РЗЛ-05.АЕ series covers protection, automation, control and signalling for 6–35 kV connections, and backup protection for 110–220 kV connections. It has 24 output relays, two RS-485 ports, Ethernet, a digital oscillograph and an event log.
- Application
- 6–35 kV connections; backup protection of 110–220 kV connections
- Auxiliary supply voltage
- 110, 220 V
- Independent supply channels
- 2
- Power consumption
- 2x13 W max.
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The РЗЛ-05.АЕ series are microprocessor relay protection and automation units for connections rated 6–35 kV, covering protection, automation, control and signalling. They also serve as backup protection and automation for 110–220 kV connections. The РЗЛ-05.АЕ-ХХ range is built on the РЗЛ-05 hardware and software platform, with no major change to the housing concept or to the system software based on freely programmable logic.
There are four versions. РЗЛ-05.АЕ-ХХ-ДЗ is for 35 kV lines, with distance protection and fault location. The -ВВ version is for 35/10(6) kV station incomers with more discrete inputs. The -СВ version protects a voltage transformer and automates a 6–35 kV bus section breaker. The -Т2 version is for two-winding transformers with a high-voltage side up to 110 kV. The number of phase currents depends on the version: 4; 7 (-Т2); 11 (-Т3). Rated phase voltage is 100 V and the measured voltage range is 5–150 V.
Discrete inputs are rated 220 V AC/DC with a pick-up level of 132–176 V and a minimum signal length of 40 ms. Input current at 220 V is 20 mA on switching on and 4 mA when on. The outputs are 24 relays, 21 with a normally open contact and 3 with a changeover contact, switching up to 400 V AC and 300 V DC.
The auxiliary supply is 110 or 220 V through two independent channels, with consumption of 2x13 W maximum. Readiness time is 0.3 s maximum, and the unit rides through a supply interruption of at least 0.4 s. Links to the control system are two RS-485 ports and Ethernet, with USB on the front panel. Protocols are MODBUS RTU, MODBUS TCP, МЭК 60870-5-104-2004 and МЭК 61850-8-1.
Functions include a digital oscillograph, an event log, arc protection with fibre-optic sensors, and programmable logic to order. The display is a 2×20 OLED, with 20 LEDs of which 16 are programmable. The unit is flush-mounted, measures 325 × 240 × 195 mm and weighs 12 kg maximum. Operating temperature is −40 to +60 °C and humidity is 98 % at 25 °С.
Technical specifications
| Application | 6–35 kV connections; backup protection of 110–220 kV connections |
|---|---|
| Auxiliary supply voltage | 110, 220 V |
| Independent supply channels | 2 |
| Power consumption | 2x13 W max. |
| Readiness time | 0.3 s max. |
| Supply interruption withstand | at least 0.4 s |
| Number of phase currents | 4; 7 (-Т2); 11 (-Т3) |
| Rated phase voltage | 100 V |
| Number of measured voltages | 4; 7 (-СВ) |
| Measured voltage range | 5–150 V |
| Discrete inputs | 220 V AC/DC; pick-up 132–176 V; signal at least 40 ms |
| Output relays | 24 (21 normally open, 3 changeover) |
| Maximum switching voltage | 400 V (AC); 300 V (DC) |
| Interfaces | RS-485 – 2 pcs, Ethernet; USB (front port) |
| Protocols | MODBUS RTU, MODBUS TCP, МЭК 60870-5-104-2004, МЭК 61850-8-1 |
| Display | OLED 2×20; 20 LEDs, 16 programmable |
| Dimensions (W×H×D) | 325 × 240 × 195 mm |
| Weight | 12 kg max. |
| Operating temperature range | −40…+60 °C |
Part numbers
Show all part numbers (4)
РЗЛ-05.АЕ-ХХ-ДЗ, РЗЛ-05.АЕ-ХХ-ВВ, РЗЛ-05.АЕ-ХХ-СВ, РЗЛ-05.АЕ-ХХ-Т2
How it compares with similar models
| Parameter | РЗЛ-05.АЕ protection and automation unit for 6–35 kV feeders, 24 output relays | РЗЛ-05.ФХ protection, automation and monitoring unit for 6-154 kV connections, 6 versions | РЗЛ-05.ВХ protection, automation and monitoring unit for 6-154 kV connections, 12 versions | РЗЛ-05.РПН on-load tap-changer control device for transformers, 12 output relays, 2 supply channels |
|---|---|---|---|---|
| Application | 6–35 kV connections; backup protection of 110–220 kV connections | protection, automation and breaker control of 6-154 kV connections | protection, automation and breaker control of 6-154 kV connections | — |
| Auxiliary supply voltage | 110, 220 V | 220 V (110 V) | 220 V (110 V) | — |
| Discrete inputs | 220 V AC/DC; pick-up 132–176 V; signal at least 40 ms | 12 (3 dry-contact) | 12 (3 dry-contact) | — |
| Output relays | 24 (21 normally open, 3 changeover) | 13 | 13 | — |
| Interfaces | RS-485 – 2 pcs, Ethernet; USB (front port) | RS-485, USB | RS-485, Ethernet, USB | USB 1 pc, RS-485 2 pcs |
European equivalents
BELplus OZE, IRV MV feeder protection terminal (V platform), HighPROTEC MRA4 protection and control terminal for feeders, networks and generators, SMPR / SMPR-2 / SMPR ETH multifunction protection terminals for MV feeders (current, voltage, power, directional protection)
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
РЗЛ-05.АЕ protection and automation unit for 6–35 kV feeders, 24 output relays. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which versions does the РЗЛ-05.АЕ series include?
Four: -ХХ-ДЗ (35 kV lines), -ХХ-ВВ (35/10(6) kV incomers), -ХХ-СВ (voltage transformer and 6–35 kV bus section breaker) and -ХХ-Т2 (two-winding transformers up to 110 kV).
What communication interfaces and protocols are fitted?
Two RS-485 ports at 9600…115200 bit/s and Ethernet at 10/100 Mbit/s, plus USB on the front. Protocols are MODBUS RTU, MODBUS TCP, МЭК 60870-5-104-2004 and МЭК 61850-8-1.
How many output relays are there and what can they switch?
There are 24 relays, 21 normally open and 3 changeover. Maximum switching voltage is 400 V AC and 300 V DC.
Similar equipment from other manufacturers