International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

РЗЛ-05.АЕ protection and automation unit for 6–35 kV feeders, 24 output relays

The РЗЛ-05.АЕ series covers protection, automation, control and signalling for 6–35 kV connections, and backup protection for 110–220 kV connections. It has 24 output relays, two RS-485 ports, Ethernet, a digital oscillograph and an event log.

Application
6–35 kV connections; backup protection of 110–220 kV connections
Auxiliary supply voltage
110, 220 V
Independent supply channels
2
Power consumption
2x13 W max.

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The РЗЛ-05.АЕ series are microprocessor relay protection and automation units for connections rated 6–35 kV, covering protection, automation, control and signalling. They also serve as backup protection and automation for 110–220 kV connections. The РЗЛ-05.АЕ-ХХ range is built on the РЗЛ-05 hardware and software platform, with no major change to the housing concept or to the system software based on freely programmable logic.

There are four versions. РЗЛ-05.АЕ-ХХ-ДЗ is for 35 kV lines, with distance protection and fault location. The -ВВ version is for 35/10(6) kV station incomers with more discrete inputs. The -СВ version protects a voltage transformer and automates a 6–35 kV bus section breaker. The -Т2 version is for two-winding transformers with a high-voltage side up to 110 kV. The number of phase currents depends on the version: 4; 7 (-Т2); 11 (-Т3). Rated phase voltage is 100 V and the measured voltage range is 5–150 V.

Discrete inputs are rated 220 V AC/DC with a pick-up level of 132–176 V and a minimum signal length of 40 ms. Input current at 220 V is 20 mA on switching on and 4 mA when on. The outputs are 24 relays, 21 with a normally open contact and 3 with a changeover contact, switching up to 400 V AC and 300 V DC.

The auxiliary supply is 110 or 220 V through two independent channels, with consumption of 2x13 W maximum. Readiness time is 0.3 s maximum, and the unit rides through a supply interruption of at least 0.4 s. Links to the control system are two RS-485 ports and Ethernet, with USB on the front panel. Protocols are MODBUS RTU, MODBUS TCP, МЭК 60870-5-104-2004 and МЭК 61850-8-1.

Functions include a digital oscillograph, an event log, arc protection with fibre-optic sensors, and programmable logic to order. The display is a 2×20 OLED, with 20 LEDs of which 16 are programmable. The unit is flush-mounted, measures 325 × 240 × 195 mm and weighs 12 kg maximum. Operating temperature is −40 to +60 °C and humidity is 98 % at 25 °С.

Technical specifications

Application6–35 kV connections; backup protection of 110–220 kV connections
Auxiliary supply voltage110, 220 V
Independent supply channels2
Power consumption2x13 W max.
Readiness time0.3 s max.
Supply interruption withstandat least 0.4 s
Number of phase currents4; 7 (-Т2); 11 (-Т3)
Rated phase voltage100 V
Number of measured voltages4; 7 (-СВ)
Measured voltage range5–150 V
Discrete inputs220 V AC/DC; pick-up 132–176 V; signal at least 40 ms
Output relays24 (21 normally open, 3 changeover)
Maximum switching voltage400 V (AC); 300 V (DC)
InterfacesRS-485 – 2 pcs, Ethernet; USB (front port)
ProtocolsMODBUS RTU, MODBUS TCP, МЭК 60870-5-104-2004, МЭК 61850-8-1
DisplayOLED 2×20; 20 LEDs, 16 programmable
Dimensions (W×H×D)325 × 240 × 195 mm
Weight12 kg max.
Operating temperature range−40…+60 °C

Part numbers

Show all part numbers (4)

РЗЛ-05.АЕ-ХХ-ДЗ, РЗЛ-05.АЕ-ХХ-ВВ, РЗЛ-05.АЕ-ХХ-СВ, РЗЛ-05.АЕ-ХХ-Т2

How it compares with similar models

ParameterРЗЛ-05.АЕ protection and automation unit for 6–35 kV feeders, 24 output relaysРЗЛ-05.ФХ protection, automation and monitoring unit for 6-154 kV connections, 6 versionsРЗЛ-05.ВХ protection, automation and monitoring unit for 6-154 kV connections, 12 versionsРЗЛ-05.РПН on-load tap-changer control device for transformers, 12 output relays, 2 supply channels
Application6–35 kV connections; backup protection of 110–220 kV connectionsprotection, automation and breaker control of 6-154 kV connectionsprotection, automation and breaker control of 6-154 kV connections—
Auxiliary supply voltage110, 220 V220 V (110 V)220 V (110 V)—
Discrete inputs220 V AC/DC; pick-up 132–176 V; signal at least 40 ms12 (3 dry-contact)12 (3 dry-contact)—
Output relays24 (21 normally open, 3 changeover)1313—
InterfacesRS-485 – 2 pcs, Ethernet; USB (front port)RS-485, USBRS-485, Ethernet, USBUSB 1 pc, RS-485 2 pcs

European equivalents

BELplus OZE, IRV MV feeder protection terminal (V platform), HighPROTEC MRA4 protection and control terminal for feeders, networks and generators, SMPR / SMPR-2 / SMPR ETH multifunction protection terminals for MV feeders (current, voltage, power, directional protection)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

РЗЛ-05.АЕ protection and automation unit for 6–35 kV feeders, 24 output relays. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which versions does the РЗЛ-05.АЕ series include?

Four: -ХХ-ДЗ (35 kV lines), -ХХ-ВВ (35/10(6) kV incomers), -ХХ-СВ (voltage transformer and 6–35 kV bus section breaker) and -ХХ-Т2 (two-winding transformers up to 110 kV).

What communication interfaces and protocols are fitted?

Two RS-485 ports at 9600…115200 bit/s and Ethernet at 10/100 Mbit/s, plus USB on the front. Protocols are MODBUS RTU, MODBUS TCP, МЭК 60870-5-104-2004 and МЭК 61850-8-1.

How many output relays are there and what can they switch?

There are 24 relays, 21 normally open and 3 changeover. Maximum switching voltage is 400 V AC and 300 V DC.