РЗЛ-01.02 microprocessor protection and automation relay for 6/35 kV networks

The РЗЛ-01.02 carries out protection, automation, control and signalling for 6-35 kV cable and overhead lines, with non-directional earth fault protection and a power supply from the current circuits. Versions РЗЛ-01.02-Д2 and РЗЛ-01.02-Д3 add extra discrete inputs.

Rated frequency
50 Hz
Frequency range
45–55 Hz
Input currents
1 A or 5 A
Operating voltage
90–250 V AC/DC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The РЗЛ-01.02 is part of the РЗЛ-01 range of microprocessor protection relays for 6-35 kV distribution networks. It provides relay protection, automation, control and signalling for outgoing cable and overhead lines, for incoming and section breakers, and backup protection for transformers. This version has non-directional earth fault protection and a power supply unit fed from the current circuits.

The relay is used as primary or backup protection in switchgear, on relay panels and in control cabinets. Input currents are 1 A or 5 A, the operating voltage is 90–250 V AC/DC and the rated frequency is 50 Hz. The current-circuit supply draws up to 1 mW per phase at rated current, and the relay rides through a short loss of supply of 500 ms at Unom = 220 V.

The three-stage overcurrent protection has current settings of 0.1–25 In and time delays of 0–32 s, independent for every stage. Settings are made by software and can be blocked, including by any discrete input. Auto-reclosing has a re-ready time setting of 5–600 s. Current measurement accuracy is up to 3 %.

Six discrete inputs for 50 Hz AC, five programmable output relays and a fault relay are fitted. The contacts switch 220 V AC at 5 A and 1000 VA. Interfaces are RS485 and RS232 with Modbus RTU. The РЗЛ-01.02-Д2 version has two extra discrete inputs (D5, D6) and the РЗЛ-01.02-Д3 has three (D4, D5, D6). Dimensions are 125x180x230 mm.

Technical specifications

Rated frequency50 Hz
Frequency range45–55 Hz
Input currents1 A or 5 A
Operating voltage90–250 V AC/DC
Power consumption, max5 VA + 0.4 VA per energised discrete output
Short supply voltage loss (at Unom = 220 V)500 ms
Self-test time after power-up250 ms
Overcurrent protectionThree-stage
Current setting range for each stage0.1 – 25 In in steps of 0.02 In
Time delay setting range for each stage0 – 32 s in steps of 0.05 s
Current measurement accuracy, max3 %
Overcurrent reset ratio0.95
Auto-reclosing re-ready time range, stages 1 and 25 – 600 s in steps of 0.1 s
Discrete inputsAC 50 Hz, Unom 220 V, U1 above 0.8 Unom, U0 below 0.45 Unom
Command output relays1 changeover, 4 normally open; fault relay changeover
AC switching capacity220 V, 5 A, 1000 VA (cosφ ≥ 0.6)
InterfacesRS485, RS232
ProtocolModbus RTU
Dimensions125х180х230 mm

Part numbers

Show all part numbers (3)

РЗЛ-01.02, РЗЛ-01.02-Д2, РЗЛ-01.02-Д3

How it compares with similar models

ParameterРЗЛ-01.02 microprocessor protection and automation relay for 6/35 kV networksРЗЛ-01.02К1 microprocessor protection and automation relay for 6/35 kV distribution networksРЗЛ-01.03 microprocessor protection and automation relay for 6-35 kV distribution networksРЗЛ-01.01 microprocessor protection and automation relay for 6-35 kV networks
Rated frequency50 Hz50 Hz50 Hz50 Hz (range 45–55 Hz)
Overcurrent protectionThree-stageThree-stageThree-stagethree-stage
Discrete inputsAC 50 Hz, Unom 220 V, U1 above 0.8 Unom, U0 below 0.45 UnomAC 50 Hz, Unom 220 V, U1 above 0.8 Unom, U0 below 0.45 UnomAC 50 Hz, Unom 220 V, U1 above 0.8 Unom, U0 below 0.45 Unom6, 220 V
Command output relays1 changeover, 4 normally open; fault relay changeover1 changeover, 4 normally open; fault relay changeover1 changeover, 4 normally open; fault relay changeover1 changeover + 4 normally open
Dimensions125х180х230 mm125х180х230 mm125х180х230 mm125x180x230 mm

European equivalents

PROTECTA DTIVA, SMPR / SMPR-2 / SMPR ETH multifunction protection terminals for MV feeders (current, voltage, power, directional protection), IRV MV feeder protection terminal (V platform), BELplus OZE

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

РЗЛ-01.02 microprocessor protection and automation relay for 6/35 kV networks. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which versions of the РЗЛ-01.02 exist?

The base РЗЛ-01.02, РЗЛ-01.02-Д2 with two extra discrete inputs and РЗЛ-01.02-Д3 with three.

What input currents and supply voltage are allowed?

Input currents of 1 A or 5 A and an operating voltage of 90–250 V AC/DC.

How is the overcurrent protection set?

Three stages with current settings of 0.1–25 In and time delays of 0–32 s, set by software and can be blocked.