РЗЛ-01.01 microprocessor protection and automation relay for 6-35 kV networks

РЗЛ-01.01 is a microprocessor relay for protection, automation, control and signalling in 6-35 kV distribution networks. It has three overcurrent stages, two auto-reclose stages, 6 discrete inputs, 5 command relays and Modbus RTU.

Rated input currents
5 A or 1 A
Rated frequency
50 Hz (range 45–55 Hz)
Auxiliary supply
90-250 V DC or AC
Power consumption
not more than 5 VA + 0,4 VA per energised discrete output

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The РЗЛ-01.01 belongs to the РЗЛ-01 series of microprocessor protection devices for 6-35 kV distribution networks. It covers protection, automation, control and signalling for outgoing cable and overhead lines, incoming and sectionalising breakers, and serves as backup protection for transformers. It can act as main or backup protection in switchgear cells, relay panels and control cabinets.

Overcurrent protection has three stages. Each stage takes a current setting of 0,1 – 25 In in steps of 0,02 In and a time delay of 0 – 32 s in steps of 0,05 s; the delays of all stages are independent. Current measurement accuracy is not more than 3% and the reset ratio is 0,95. Settings are entered in software, and any stage can be blocked, including from any discrete input.

Auto-reclosing has two stages. The operating time of the stages is 0 - 600 s in steps of 0,1 s, the re-ready time is 5 - 600 s in steps of 0,1 s. Stages are blocked either in software or through a discrete input.

There are 6 optically isolated discrete inputs for a control voltage of 220 V DC or 220 V AC at 50 Hz. The programmable command relays number five, one changeover and four normally open, plus a separate changeover fault relay. Contacts switch 220 V AC at 5 A, 1000 VA (cosφ ≥ 0,6), with a continuous current of 8 A.

The auxiliary supply is 90-250 V DC or AC and the rated input current is 5 A or 1 A. After power-up the self-test takes 250 ms, and a short supply loss of up to 500 ms is tolerated at Uном = 220 V. Communication runs over RS485 or RS232 with the Modbus RTU protocol, and configuration software is available. Dimensions are 125x180x230 mm.

Technical specifications

Rated input currents5 A or 1 A
Rated frequency50 Hz (range 45–55 Hz)
Auxiliary supply90-250 V DC or AC
Power consumptionnot more than 5 VA + 0,4 VA per energised discrete output
Overcurrent protectionthree-stage
Current settings (each stage)0,1 – 25 In, step 0,02 In
Stage time delay0 – 32 s, step 0,05 s
Current measurement accuracynot more than 3%
Reset ratio0,95
Auto-reclose stage time0 - 600 s, step 0,1 s
Auto-reclose ready time5 - 600 s, step 0,1 s
Discrete inputs6, 220 V
Command output relays1 changeover + 4 normally open
Fault relay1 changeover
Contact rating, AC220 V, 5 A, 1000 VA (cosφ ≥ 0,6)
Continuous contact current8 A
Interfaces and protocolRS485, RS232; Modbus RTU
Dimensions125x180x230 mm

Part numbers

Show all part numbers (1)

РЗЛ-01.01

How it compares with similar models

ParameterРЗЛ-01.01 microprocessor protection and automation relay for 6-35 kV networksРЗЛ-01.03 microprocessor protection and automation relay for 6-35 kV distribution networksРЗЛ-01.02К1 microprocessor protection and automation relay for 6/35 kV distribution networksРЗЛ-01.02 microprocessor protection and automation relay for 6/35 kV networks
Rated frequency50 Hz (range 45–55 Hz)50 Hz50 Hz50 Hz
Overcurrent protectionthree-stageThree-stageThree-stageThree-stage
Discrete inputs6, 220 VAC 50 Hz, Unom 220 V, U1 above 0.8 Unom, U0 below 0.45 UnomAC 50 Hz, Unom 220 V, U1 above 0.8 Unom, U0 below 0.45 UnomAC 50 Hz, Unom 220 V, U1 above 0.8 Unom, U0 below 0.45 Unom
Command output relays1 changeover + 4 normally open1 changeover, 4 normally open; fault relay changeover1 changeover, 4 normally open; fault relay changeover1 changeover, 4 normally open; fault relay changeover
Dimensions125x180x230 mm125х180х230 mm125х180х230 mm125х180х230 mm

European equivalents

PROTECTA DTIVA, SMPR / SMPR-2 / SMPR ETH multifunction protection terminals for MV feeders (current, voltage, power, directional protection), IRV MV feeder protection terminal (V platform), BELplus OZE

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

РЗЛ-01.01 microprocessor protection and automation relay for 6-35 kV networks. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many overcurrent stages does the РЗЛ-01.01 have and what are the settings?

There are three stages. The current setting of each stage is 0,1 – 25 In in steps of 0,02 In, and the time delay is 0 – 32 s in steps of 0,05 s.

Which communication interfaces and protocol are fitted?

The device has RS485 and RS232 interfaces and uses the Modbus RTU protocol.

What supply and rated currents does the РЗЛ-01.01 need?

The auxiliary supply is 90-250 V DC or AC, and the rated input current is 5 A or 1 A at 50 Hz.