AL-4-1, AL-4-2 earth-fault current relays (АЛ-4-1, АЛ-4-2), 0.02-0.2 A

АЛ-4-1 and АЛ-4-2 (AL-4-1, AL-4-2) are single-circuit earth-fault current relays with settings from 0.02 to 0.2 A. The АЛ-4-1 has an adjustable delay, the АЛ-4-2 operates with no delay and takes an auxiliary supply.

Rated supply voltage
DC 110 V; 220 V, AC 110 V; 220 V
Rated input current
0.16 A, 50 Hz
Trip setting range
0.02 to 0.2 A
Setting step
0.002 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

These relays monitor earth-fault current through one current circuit and are highly sensitive. They work with a zero-sequence current transformer in earth-fault protection schemes, and also in other protection, emergency and industrial automation schemes.

The АЛ-4-1 corresponds fully to the АЛ-4 but adds an adjustable operate delay of 0.1-10 s or 0.3-30 s. The АЛ-4-2 is an instantaneous relay with an auxiliary supply. Supply voltage is DC 110 V or 220 V, or AC 110 V or 220 V.

Rated input current is 0.16 A at 50 Hz and the trip setting runs from 0.02 to 0.2 A in 0.002 A steps. Operate time at 3 times the setting is not more than 0.04 s. Reset ratio is not less than 0.9 and accuracy class is 5.

Contacts switch 0.02 to 2 A at 24 to 250 V. DC power is up to 60 W at τ = 0.005 s and up to 30 W at τ = 0.02 s; AC power is up to 300 VA at cosφ = 0.5. Continuous contact current is not more than 4 A. Mechanical life is not less than 100000 cycles, switching life not less than 20000 cycles, and mean service life is 12 years.

Install the relay indoors at minus 40 to plus 55 °C and 80% relative humidity at 25 °C, in a non-explosive atmosphere free of dust and gases that attack insulation. Mounting-point vibration must not exceed 3g up to 15 Hz and 1g up to 100 Hz. The case is IP40, the terminals IP20, and the mass is not more than 0.8 kg. Fix it on a DIN rail or on a flat surface.

Technical specifications

Rated supply voltageDC 110 V; 220 V, AC 110 V; 220 V
Rated input current0.16 A, 50 Hz
Trip setting range0.02 to 0.2 A
Setting step0.002 A
Operate time at 3 times the settingnot more than 0.04 s
Adjustable delay, АЛ-4-10.1-10 s or 0.3-30 s
Reset rationot less than 0.9
Accuracy class5
Contact current0.02 to 2 A
Contact voltage24 to 250 V
Contact power, DCup to 60 W at τ = 0.005 s; up to 30 W at τ = 0.02 s
Contact power, ACup to 300 VA at cosφ = 0.5
Continuous contact currentnot more than 4 A
Mechanical lifenot less than 100000 cycles
Switching lifenot less than 20000 cycles
Mean service life12 years
Protection degree, case / terminalsIP40 / IP20
Massnot more than 0.8 kg

Part numbers

Show all part numbers (2)

АЛ-4-1, АЛ-4-2

How it compares with similar models

ParameterAL-4-1, AL-4-2 earth-fault current relays (АЛ-4-1, АЛ-4-2), 0.02-0.2 AAL-4 earth-fault current relay (АЛ-4), settings 0.005-0.150 AАЛ-1 AC overcurrent relay, settings 0.05-100 A in five rangesВЛ-50 time relay for railway rolling stock, 2–200 s settings, 27–110 V DC supply
Rated supply voltageDC 110 V; 220 V, AC 110 V; 220 VDC 110 V; 220 V, AC 110 V; 220 V (by version)=110, 220 V; ~100, 220 VDC 27, 50, 75, 110 V
Setting step0.002 A0.0015 A0.005; 0.0125; 0.05; 0.25; 1.25 A—
Reset rationot less than 0.9not less than 0.93not less than 0.9—
Accuracy class5554/0.1

European equivalents

Earth Fault Locator selective detection of the feeder with an earth fault, Earth 4.0 / Earth Zero / Earth Zero Flag earth fault indicators with a sum current sensor

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

AL-4-1, AL-4-2 earth-fault current relays (АЛ-4-1, АЛ-4-2), 0.02-0.2 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do the АЛ-4-1 and АЛ-4-2 differ?

The АЛ-4-1 has an adjustable delay of 0.1-10 s or 0.3-30 s; the АЛ-4-2 operates instantaneously and takes an auxiliary supply.

What is the current setting range?

From 0.02 to 0.2 A in steps of 0.002 A.

What sensor does the relay work with?

A zero-sequence current transformer in earth-fault protection schemes.