International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

ВЛ-50 time relay for railway rolling stock, 2–200 s settings, 27–110 V DC supply

The ВЛ-50 switches circuits after set delays in automation systems and is fitted in the control systems of diesel locomotives and track machines. Settings run from 2 to 200 s, supply is 27, 50, 75 or 110 V DC and the contacts are 1з + 1р.

Setting range
2–200 s
Delay adjustment
stepped, 100 steps
Accuracy class
4/0.1
Return time
0.2 s max.

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ВЛ-50 is a time relay for switching electrical circuits after defined delays in automation systems. It is installed as a component in the control systems of diesel locomotives and track machines. It is built for harsh service, with an operating temperature range of minus 60 to plus 60 °C.

The delay is set between 2 s and 200 s in 100 steps. Accuracy class is 4/0.1, meaning the mean basic error at any marked scale point stays within a value calculated from the maximum setting of the range and the setting being tested. Return time is 0.2 s maximum.

Rated DC supply is 27, 50, 75 or 110 V, and the relay works with supply deviations from 0.7 to 1.2 of rated voltage. Power consumption is 5 W maximum. The output has one normally open and one normally closed contact (1з + 1р). Continuous current through the output contacts is 4 A maximum, and the minimum switched current is 0.05 A. Mechanical endurance is at least 10⁷ cycles.

Two versions are made, У3 and В3. Version В is for all land and sea macro-climatic regions except very cold ones. The relay is used indoors with natural ventilation and no artificially controlled climate, placement category 3. Ambient air limits are minus 60 and plus 70 °C.

The mounting points withstand vibration up to 100 Hz at an acceleration of up to 9.8 m/s² (1g), and single shocks up to 29.4 m/s² (3g) lasting 40–60 ms. Protection is IP40 for the enclosure and IP10 for the connector, and weight is 0.35 kg maximum. Relays with other parameters can be made by agreement between manufacturer and user.

Technical specifications

Setting range2–200 s
Delay adjustmentstepped, 100 steps
Accuracy class4/0.1
Return time0.2 s max.
Rated supply voltageDC 27, 50, 75, 110 V
Supply voltage deviation0.7 to 1.2 of rated voltage
Power consumption5 W max.
Output contacts1з + 1р
Continuous contact current4 A max.
Minimum switched current0.05 A
Mechanical enduranceat least 10⁷ cycles
VersionsУ3 and В3
Operating temperature range−60…+60 °C
Protection degreeIP40 (enclosure) / IP10 (connector)
Weight0.35 kg max.

How it compares with similar models

ParameterВЛ-50 time relay for railway rolling stock, 2–200 s settings, 27–110 V DC supplyAL-4-1, AL-4-2 earth-fault current relays (АЛ-4-1, АЛ-4-2), 0.02-0.2 AАЛ-1 AC overcurrent relay, settings 0.05-100 A in five rangesВЛ-108 (VL-108) single-shot auto-reclose time relay, DC 100, 220 V, AC 110, 220, 230 V
Accuracy class4/0.155—
Rated supply voltageDC 27, 50, 75, 110 VDC 110 V; 220 V, AC 110 V; 220 V=110, 220 V; ~100, 220 VDC 100, 220 V; AC 110, 220, 230 V

Request a price and lead time

ВЛ-50 time relay for railway rolling stock, 2–200 s settings, 27–110 V DC supply. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What supply voltages are available for the ВЛ-50?

Rated DC supply is 27, 50, 75 or 110 V. The relay works with deviations from 0.7 to 1.2 of rated voltage.

What temperature range does it cover?

Operating range is minus 60 to plus 60 °C, with ambient air limits of minus 60 and plus 70 °C.

What output and contact load does it have?

One normally open and one normally closed contact (1з + 1р). Continuous current is 4 A maximum and the minimum switched current is 0.05 A.

Similar equipment from other manufacturers