SCMS stray current monitoring system for traction networks
The SCMS (STELLA-SCMS) continuously measures rail-to-earth potential and prevents corrosion damage from stray currents in railway and non-railway installations. It follows the recommendations of EN 50122-2 and takes up to 100 measuring points per system.
- Product type
- Stray current monitoring system (STELLA-SCMS)
- Number of measuring points
- 100 for one system
- Frequency of acquisition
- 1 s
- Data analysis
- Central Evaluation Unit (CEU)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SCMS prevents corrosion caused by stray currents on equipment in railway and non-railway installations. When stray currents leave the intended traction current return path and flow to the earth, or through other structural components, to return to the traction substation, any metal part buried in soil corrodes.
The system removes the need for repetitive manual measurement and does not interfere with the stray current collection system. It follows the recommendations of EN 50122-2:2011 and continuously measures rail-to-earth potential in operating conditions. A Central Evaluation Unit (CEU) handles data analysis, display, signalling and logging.
Data comes from the VGUARD voltage limiting device or from a measuring plate. One system takes up to 100 measuring points with a 1 s frequency of acquisition. Communication protocols are IEC 61850, IEC 60870-5-104 (-5-101) and Modbus TCP.
Instantaneous values are kept as a function of time over 16 weeks. Short and long analysis values, as averages or averages of the absolute value against time or position, are archived for 10 years minimum, with an averaging window from 1 to 60 min for each analysis. The interface is multilingual.
Further functions are constant automated analysis, fault alarm and location, data export and backup, and data acquisition and transmission. Specific algorithms can be integrated, and measurement and certification before operation can be provided. Application is DC traction power supply for railways.
Technical specifications
| Product type | Stray current monitoring system (STELLA-SCMS) |
|---|---|
| Number of measuring points | 100 for one system |
| Frequency of acquisition | 1 s |
| Data analysis | Central Evaluation Unit (CEU) |
| Data sources | VGUARD voltage limiting device or measuring plate |
| Communication protocols | IEC 61850, IEC 60870-5-104 (-5-101), Modbus TCP |
| Instantaneous values | as a function of time, 16 weeks |
| Analysis value archiving | 10 years minimum |
| Averaging window | from 1 to 60 min (short and long analysis) |
| Measured quantity | rail-to-earth potential |
| Standard | EN 50122-2:2011 |
Request a price and lead time
SCMS stray current monitoring system for traction networks. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How many measuring points can one system take?
Up to 100 measuring points per system, with a 1 s frequency of acquisition.
How long is data kept?
Instantaneous values are kept for 16 weeks, and short and long analysis values are archived for 10 years minimum.
Which communication protocols are available?
IEC 61850, IEC 60870-5-104 (-5-101) and Modbus TCP.