SCMS stray current monitoring system for traction networks

The SCMS (STELLA-SCMS) continuously measures rail-to-earth potential and prevents corrosion damage from stray currents in railway and non-railway installations. It follows the recommendations of EN 50122-2 and takes up to 100 measuring points per system.

Product type
Stray current monitoring system (STELLA-SCMS)
Number of measuring points
100 for one system
Frequency of acquisition
1 s
Data analysis
Central Evaluation Unit (CEU)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SCMS prevents corrosion caused by stray currents on equipment in railway and non-railway installations. When stray currents leave the intended traction current return path and flow to the earth, or through other structural components, to return to the traction substation, any metal part buried in soil corrodes.

The system removes the need for repetitive manual measurement and does not interfere with the stray current collection system. It follows the recommendations of EN 50122-2:2011 and continuously measures rail-to-earth potential in operating conditions. A Central Evaluation Unit (CEU) handles data analysis, display, signalling and logging.

Data comes from the VGUARD voltage limiting device or from a measuring plate. One system takes up to 100 measuring points with a 1 s frequency of acquisition. Communication protocols are IEC 61850, IEC 60870-5-104 (-5-101) and Modbus TCP.

Instantaneous values are kept as a function of time over 16 weeks. Short and long analysis values, as averages or averages of the absolute value against time or position, are archived for 10 years minimum, with an averaging window from 1 to 60 min for each analysis. The interface is multilingual.

Further functions are constant automated analysis, fault alarm and location, data export and backup, and data acquisition and transmission. Specific algorithms can be integrated, and measurement and certification before operation can be provided. Application is DC traction power supply for railways.

Technical specifications

Product typeStray current monitoring system (STELLA-SCMS)
Number of measuring points100 for one system
Frequency of acquisition1 s
Data analysisCentral Evaluation Unit (CEU)
Data sourcesVGUARD voltage limiting device or measuring plate
Communication protocolsIEC 61850, IEC 60870-5-104 (-5-101), Modbus TCP
Instantaneous valuesas a function of time, 16 weeks
Analysis value archiving10 years minimum
Averaging windowfrom 1 to 60 min (short and long analysis)
Measured quantityrail-to-earth potential
StandardEN 50122-2:2011

Request a price and lead time

SCMS stray current monitoring system for traction networks. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many measuring points can one system take?

Up to 100 measuring points per system, with a 1 s frequency of acquisition.

How long is data kept?

Instantaneous values are kept for 16 weeks, and short and long analysis values are archived for 10 years minimum.

Which communication protocols are available?

IEC 61850, IEC 60870-5-104 (-5-101) and Modbus TCP.