PALB load break switch panels for DC traction substations
PALB (ESTRA-PALB) load break switch panels for indoor and outdoor or wayside installation. Rated current is up to 6000 A, rated voltage 900 V, 1800 V or 3600 V, and control voltage 24 to 220 VDC.
- Product type
- DC load break switch panels (ESTRA-PALB)
- DC rated current
- up to 6000 A
- Rated voltage
- 900 V, 1800 V, 3600 V
- Poles
- 1 or 2
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
PALB load break switch panels belong to the ESTRA range and cover load break switch cubicles in railway DC traction power substations. The integration includes LBS-type on-load switches. The panels are available for indoor and for outdoor or wayside installation, with over-area and intersection load-break switches. A wide range of configurations meets most needs and can be extended on request.
The DC rated current is up to 6000 A and the rated voltage is 900 V, 1800 V or 3600 V. Panels have 1 or 2 poles. Making and breaking capacity and short-time withstand currents are adapted to the application. Control voltage runs from 24 to 220 VDC. Operation is electrical or manual.
Panel dimensions can be adapted for wayside or tunnel installation. Optional electrical and mechanical interlocks and a key interlock mechanism support safe operation, and the low voltage compartment can be segregated.
Reference standards are EN 50123-3 and IEC 61992-3, and the panels are type tested to EN 50123-3.
Typical uses are DC switchgear, indoor and outdoor DC distribution boards, railway DC traction power supply and e-mining truck electrification. The panels offer high mechanical and electrical durability and low maintenance.
Technical specifications
| Product type | DC load break switch panels (ESTRA-PALB) |
|---|---|
| DC rated current | up to 6000 A |
| Rated voltage | 900 V, 1800 V, 3600 V |
| Poles | 1 or 2 |
| Control voltage | from 24 to 220 VDC |
| Making and breaking capacity | adapted to applications |
| Short-time withstand currents | adapted to applications |
| Installation | indoor, outdoor and wayside |
| Operation | electrical and manual |
| Interlocks | electrical and mechanical (optional), key interlock |
| Standards | EN 50123-3, IEC 61992-3 |
How it compares with similar models
| Parameter | PALB load break switch panels for DC traction substations | PADS disconnect switch panels for DC traction substations | MBS high-speed circuit breaker panels for DC traction substations | UR DC circuit breakers for traction substations to EN/IEC standards, 900–3600 VDC |
|---|---|---|---|---|
| Product type | DC load break switch panels (ESTRA-PALB) | DC disconnect switch panels (ESTRA-PADS) | DC high-speed circuit breaker panels (ESTRA-MBS) | — |
| DC rated current | up to 6000 A | up to 8000 A | up to 8000 A | — |
| Rated voltage | 900 V, 1800 V, 3600 V | 900 V, 1800 V, 3600 V | 900 V, 1800 V, 3600 V | 900 VDC, 1800 VDC, 3600 VDC |
| Control voltage | from 24 to 220 VDC | from 24 to 220 VDC, 230 VAC | from 24 to 220 VDC, 230 VAC | 24 - 220 VDC or rectified 230 VAC |
| Standards | EN 50123-3, IEC 61992-3 | EN 50123-3, IEC 61992-3, IEEE ANSI C37.20.1 | EN 50123, IEC 61992, IEEE ANSI C37.20.1, C37.14 | — |
Request a price and lead time
PALB load break switch panels for DC traction substations. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What are the rated current and voltage of the PALB panels?
The DC rated current is up to 6000 A and the rated voltage is 900 V, 1800 V or 3600 V.
Can the switch be operated by hand?
Yes, operation is electrical or manual. Control voltage runs from 24 to 220 VDC.
Are the panels suitable for tunnels and wayside installation?
Yes, panel dimensions can be adapted for wayside or tunnel installation.