PALB load break switch panels for DC traction substations

PALB (ESTRA-PALB) load break switch panels for indoor and outdoor or wayside installation. Rated current is up to 6000 A, rated voltage 900 V, 1800 V or 3600 V, and control voltage 24 to 220 VDC.

Product type
DC load break switch panels (ESTRA-PALB)
DC rated current
up to 6000 A
Rated voltage
900 V, 1800 V, 3600 V
Poles
1 or 2

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

PALB load break switch panels belong to the ESTRA range and cover load break switch cubicles in railway DC traction power substations. The integration includes LBS-type on-load switches. The panels are available for indoor and for outdoor or wayside installation, with over-area and intersection load-break switches. A wide range of configurations meets most needs and can be extended on request.

The DC rated current is up to 6000 A and the rated voltage is 900 V, 1800 V or 3600 V. Panels have 1 or 2 poles. Making and breaking capacity and short-time withstand currents are adapted to the application. Control voltage runs from 24 to 220 VDC. Operation is electrical or manual.

Panel dimensions can be adapted for wayside or tunnel installation. Optional electrical and mechanical interlocks and a key interlock mechanism support safe operation, and the low voltage compartment can be segregated.

Reference standards are EN 50123-3 and IEC 61992-3, and the panels are type tested to EN 50123-3.

Typical uses are DC switchgear, indoor and outdoor DC distribution boards, railway DC traction power supply and e-mining truck electrification. The panels offer high mechanical and electrical durability and low maintenance.

Technical specifications

Product typeDC load break switch panels (ESTRA-PALB)
DC rated currentup to 6000 A
Rated voltage900 V, 1800 V, 3600 V
Poles1 or 2
Control voltagefrom 24 to 220 VDC
Making and breaking capacityadapted to applications
Short-time withstand currentsadapted to applications
Installationindoor, outdoor and wayside
Operationelectrical and manual
Interlockselectrical and mechanical (optional), key interlock
StandardsEN 50123-3, IEC 61992-3

How it compares with similar models

ParameterPALB load break switch panels for DC traction substationsPADS disconnect switch panels for DC traction substationsMBS high-speed circuit breaker panels for DC traction substationsUR DC circuit breakers for traction substations to EN/IEC standards, 900–3600 VDC
Product typeDC load break switch panels (ESTRA-PALB)DC disconnect switch panels (ESTRA-PADS)DC high-speed circuit breaker panels (ESTRA-MBS)—
DC rated currentup to 6000 Aup to 8000 Aup to 8000 A—
Rated voltage900 V, 1800 V, 3600 V900 V, 1800 V, 3600 V900 V, 1800 V, 3600 V900 VDC, 1800 VDC, 3600 VDC
Control voltagefrom 24 to 220 VDCfrom 24 to 220 VDC, 230 VACfrom 24 to 220 VDC, 230 VAC24 - 220 VDC or rectified 230 VAC
StandardsEN 50123-3, IEC 61992-3EN 50123-3, IEC 61992-3, IEEE ANSI C37.20.1EN 50123, IEC 61992, IEEE ANSI C37.20.1, C37.14—

Request a price and lead time

PALB load break switch panels for DC traction substations. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What are the rated current and voltage of the PALB panels?

The DC rated current is up to 6000 A and the rated voltage is 900 V, 1800 V or 3600 V.

Can the switch be operated by hand?

Yes, operation is electrical or manual. Control voltage runs from 24 to 220 VDC.

Are the panels suitable for tunnels and wayside installation?

Yes, panel dimensions can be adapted for wayside or tunnel installation.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides