VGUARD voltage limiting devices for railway DC traction
The VGUARD (ESTRA-VGUARD) voltage limiting device limits dangerous touch voltages in railway DC traction systems. Rated voltage is up to 3600 V and rated current up to 1200 A.
- Product type
- Voltage limiting device for railway DC traction (ESTRA-VGUARD)
- Rated voltage
- up to 3600 V
- Rated current
- up to 1200 A
- Application
- limitation of dangerous touch voltages
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
During normal operation of a railway electrical system, dangerous voltages can appear at accessible points of the return and earthing circuits. They come from voltage drops along the return circuit caused by train traffic or insulation faults. To keep them below the admissible values of EN 50122-1, a voltage limiting device is fitted as a short-circuiter between the negative and earth potentials.
VGUARD is built on proven technologies from the manufacturer and meets the electrical safety and internal arc testing requirements of EN 50122-1 and EN 50526-2. Its application is limiting dangerous touch voltages. VGuard-B (Basic) is designed to Class 3 of EN 50526-2 and VGuard-H (Hybrid) to Class 4 of EN 50526-2.
Rated voltage is up to 3600 V and rated current up to 1200 A. Operation is by remote motor or manually on site. Movable connections allow the equipment to be by-passed or isolated for safe testing or maintenance. Making current and short-time withstand currents are adapted to the application. Control voltage runs from 24 to 220 VDC or 230 VAC.
The protection degree is IP42 for indoor or IP65 for outdoor use. Panel dimensions can be adapted for wayside or tunnel installation. The device can optionally be combined with the SCMS stray current monitoring system.
Response is fast, operation and protection are bidirectional, and recovery is automatic with a low residual voltage. The device protects personnel, passengers and the installation. It is type tested against internal arcs to EN 50526-2, with high mechanical and electrical durability and low maintenance. Typical uses are railway DC traction power supply and e-mining truck electrification.
Technical specifications
| Product type | Voltage limiting device for railway DC traction (ESTRA-VGUARD) |
|---|---|
| Rated voltage | up to 3600 V |
| Rated current | up to 1200 A |
| Application | limitation of dangerous touch voltages |
| VGuard-B (Basic) | designed to Class 3 of EN 50526-2 |
| VGuard-H (Hybrid) | designed to Class 4 of EN 50526-2 |
| Operation | remote motorised or manual on site |
| Control voltage | from 24 to 220 VDC, 230 VAC |
| Protection degree | IP42 for indoor, IP65 for outdoor |
| Standards | EN 50122-1, EN 50526-2 |
How it compares with similar models
| Parameter | VGUARD voltage limiting devices for railway DC traction | MBS high-speed circuit breaker panels for DC traction substations | PADS disconnect switch panels for DC traction substations | PALB load break switch panels for DC traction substations |
|---|---|---|---|---|
| Product type | Voltage limiting device for railway DC traction (ESTRA-VGUARD) | DC high-speed circuit breaker panels (ESTRA-MBS) | DC disconnect switch panels (ESTRA-PADS) | DC load break switch panels (ESTRA-PALB) |
| Rated voltage | up to 3600 V | 900 V, 1800 V, 3600 V | 900 V, 1800 V, 3600 V | 900 V, 1800 V, 3600 V |
| Control voltage | from 24 to 220 VDC, 230 VAC | from 24 to 220 VDC, 230 VAC | from 24 to 220 VDC, 230 VAC | from 24 to 220 VDC |
| Standards | EN 50122-1, EN 50526-2 | EN 50123, IEC 61992, IEEE ANSI C37.20.1, C37.14 | EN 50123-3, IEC 61992-3, IEEE ANSI C37.20.1 | EN 50123-3, IEC 61992-3 |
Request a price and lead time
VGUARD voltage limiting devices for railway DC traction. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How do VGuard-B and VGuard-H differ?
VGuard-B (Basic) is designed to Class 3 of EN 50526-2, and VGuard-H (Hybrid) to Class 4 of EN 50526-2.
What does the device do in a traction system?
It acts as a short-circuiter between the negative and earth potentials and keeps voltages below the admissible values of EN 50122-1.
What are its protection degree and operating modes?
IP42 for indoor or IP65 for outdoor use. Operation is by remote motor or manually on site.