International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

DC voltage and current sensors for rail vehicles

DC voltage and current sensors for rail vehicles on 0.75 kVDC, 1.5 kVDC and 3 kVDC networks. The maximum measuring range reaches ±4.2 kV and ±4000 A, with operation from –40°C to +70°C.

Product type
DC voltage and current sensors for rail vehicles
DC networks
0.75 kV, 1.5 kV and/or 3 kV
Maximum measuring voltage range
up to ±4.2 kV
Maximum measuring current range
up to ±4000 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

These sensors are for DC rail vehicles running on 0.75 kVDC, 1.5 kVDC or 3 kVDC networks. The selected voltage and current sensors serve voltage detection, energy measurement, traction control and vehicle protection.

They are built on proven measuring techniques: Hall effect, shunt-type measurement, voltage dividers and others. They are delivered inside the DC MODBOX®, a compact enclosure that houses a DC circuit breaker from the same manufacturer together with other high-voltage components.

The maximum measuring voltage range is up to ±4.2 kV and the maximum measuring current range is up to ±4000 A. Accuracy class and technical data follow the requirements of the application. For wider energy metering, the energy meter includes the Energy Calculation Function (ECF) and the Data Handling System (DHS).

The sensors are for indoor installation and suit ambient temperatures from –40°C to +70°C. Reference standards, depending on the version, are EN 50155 and 50463-2 / IEC 62888-2. Insulation material is according to EN 45545-2.

Intended vehicles are DC rail vehicles, AC/DC multisystem vehicles and dual mode rail vehicles. Supplying ready-fitted sensors inside the MODBOX® cuts engineering work and risk, and streamlines logistics and installation.

Technical specifications

Product typeDC voltage and current sensors for rail vehicles
DC networks0.75 kV, 1.5 kV and/or 3 kV
Maximum measuring voltage rangeup to ±4.2 kV
Maximum measuring current rangeup to ±4000 A
Accuracy classbased on application requirements
Measuring techniquesHall effect, shunt-type measurement, voltage dividers
Installationindoor
Ambient temperature–40°C to +70°C
StandardsEN 50155, 50463-2 / IEC 62888-2 (based on versions), EN 45545-2

How it compares with similar models

ParameterDC voltage and current sensors for rail vehiclesTMS AC voltage and current sensors for rolling stockMACS/BVAC AC vacuum circuit breakers for rail vehicles, 15/25 kVVGUARD voltage limiting devices for railway DC traction
Product typeDC voltage and current sensors for rail vehiclesAC voltage and current sensors for rolling stock (TMS)—Voltage limiting device for railway DC traction (ESTRA-VGUARD)
Installationindoorvertical and horizontal, indoor or outdoorvertical and horizontal—
Ambient temperature–40°C to +70°C-40°C to +70°C– 40°C - +70°C (option: -50°C - +55°C)—
StandardsEN 50155, 50463-2 / IEC 62888-2 (based on versions), EN 45545-2EN 50463-2 / IEC 62888-2, IEC 61869-2, EN/IEC 60044-7, EN 45545-2—EN 50122-1, EN 50526-2

Request a price and lead time

DC voltage and current sensors for rail vehicles. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which DC networks are the sensors made for?

DC rail vehicles on 0.75 kV, 1.5 kV and/or 3 kV networks.

What is the maximum measuring range?

Up to ±4.2 kV for voltage and up to ±4000 A for current. The accuracy class follows the application requirements.

How are the sensors supplied?

Integrated with a DC circuit breaker from the same manufacturer inside the DC MODBOX® enclosure. They are for indoor installation.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides