International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TMS AC voltage and current sensors for rolling stock

A traction measurement system for rail vehicles with 3 AC voltage outputs and 2 AC current outputs of class 0.5 R, plus optional catenary voltage detection. It measures AC catenary voltage from 11 kV to 25 kV and runs from a 24 to 110 VDC supply.

Product type
AC voltage and current sensors for rolling stock (TMS)
AC voltage outputs
3 outputs, class 0.5 R
DC voltage output
1 output, class 0.5 R
AC current outputs
2 outputs, class 0.5 R

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TMS is a traction measurement system for rail vehicles. It provides AC voltage and current measurement signals of accuracy class 0.5 R, suitable for energy measurement, traction control and vehicle protection. It also passes catenary voltage detection information to the vehicle train control and management system (TCMS). Used with compatible energy meters, it forms the energy measurement function to EN 50463 / IEC 62888.

Two configurations are offered: a stand-alone Voltage Measurement Function (VMF) and a combined Voltage and Current Measurement Function (VMF and CMF). The outputs are insulated, so signals reach on-board equipment safely and accurately. The unit has 3 outputs for AC voltage, 2 outputs for AC current and 4 digital outputs for catenary voltage detection. Options include 1 output for DC voltage measurement of class 0.5 R, AC and DC catenary voltage detection, and an output offset for safety-critical applications.

Any AC catenary voltage from 11 kV to 25 kV can be measured at a frequency between 16.7 Hz and 60 Hz, as can any DC catenary voltage between 750 V and 3 kV. Vehicle input current is measured from 100 A to 630 A at 15 kVAC and from 60 A to 400 A at 25 kVAC. Insulation voltage is 31.5 kVAC, impulse withstand voltage is 170 kV and the auxiliary supply is 24 to 110 VDC.

Signals travel over a current loop for noise immunity, with no delay or jitter between inputs and outputs. The electronics are simple and contain no embedded software. The unit is compact, lightweight and safe against internal arcs.

It installs vertically or horizontally, indoors or outdoors, at ambient temperatures from –40°C to +70°C. It can be mounted on its own on the vehicle roof or built into the MODBOX® high-voltage enclosure alongside other high- and low-voltage functions. Intended vehicles are AC rail vehicles, AC/DC multisystem vehicles and dual mode vehicles. Reference standards are EN 50463-2 / IEC 62888-2, IEC 61869-2 and EN/IEC 60044-7, with insulation material to EN 45545-2. The unit is certified TSI Loc&Pass.

Technical specifications

Product typeAC voltage and current sensors for rolling stock (TMS)
AC voltage outputs3 outputs, class 0.5 R
DC voltage output1 output, class 0.5 R
AC current outputs2 outputs, class 0.5 R
Digital outputs for catenary voltage detection4
AC catenary voltage11 kV to 25 kV, frequency 16.7 Hz to 60 Hz
DC catenary voltage750 V to 3 kV
Vehicle input current100 A to 630 A (15 kVAC), 60 A to 400 A (25 kVAC)
Insulation voltage31.5 kVAC
Impulse withstand voltage170 kV
Auxiliary supply voltage24 to 110 VDC
Ambient temperature-40°C to +70°C
Installationvertical and horizontal, indoor or outdoor
StandardsEN 50463-2 / IEC 62888-2, IEC 61869-2, EN/IEC 60044-7, EN 45545-2

How it compares with similar models

ParameterTMS AC voltage and current sensors for rolling stockDC voltage and current sensors for rail vehiclesMACS/BVAC AC vacuum circuit breakers for rail vehicles, 15/25 kVAC MODFRAME integrated roof frame for AC rail vehicles, up to 630 A (AC)
Ambient temperature-40°C to +70°C–40°C to +70°C– 40°C - +70°C (option: -50°C - +55°C)—
Installationvertical and horizontal, indoor or outdoorindoorvertical and horizontalroof installation in open air

Request a price and lead time

TMS AC voltage and current sensors for rolling stock. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What accuracy class do the measurement outputs have?

The AC voltage, DC voltage and AC current outputs are all class 0.5 R, which suits energy measurement.

What catenary voltages can the TMS measure?

AC from 11 kV to 25 kV at a frequency between 16.7 Hz and 60 Hz, and DC between 750 V and 3 kV.

Does the TMS contain embedded software?

No, the electronic architecture is simple and has no embedded software. The auxiliary supply is 24 to 110 VDC.