AC MODFRAME integrated roof frame for AC rail vehicles, up to 630 A (AC)
The AC MODFRAME gathers the high voltage roof components of AC and AC/DC EMUs and trains on one frame installed in the open air. Thermal current is up to 630 A (AC) and 2600 A (DC), and the height above the roof is 545 mm or less.
- Type
- Integrated roof frame for high voltage equipment
- AC applications
- 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz)
- DC applications (AC/DC vehicles)
- 1.5 kVDC and/or 3 kVDC
- Thermal current
- up to 630 A (AC) and 2600 A (DC)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The AC MODFRAME is an integrated solution for AC and AC/DC Electrical Multiple Units (EMU) and trains. The high voltage roof components needed to operate and protect the vehicle sit on one frame in the open air, and the frame is easily adapted to different roof scopes, layouts and fixations.
The main integrated functions are an AC circuit breaker with or without synchronous switching, an earthing device, voltage detection, voltage and current measurement, roof disconnectors, a voltage selector and surge arresters. AC applications are 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz); DC applications for AC/DC vehicles are 1.5 kVDC and/or 3 kVDC. Thermal current is up to 630 A (AC) and 2600 A (DC), and height above the roof is 545 mm or less.
Busbars, cables and braids connect every component, so the car builder has a simple interface for the high voltage connections. Low voltage cables go directly to the components through easily accessible outdoor type connectors. Installation on the roof needs no cut-out unless manual operation is chosen for the earthing device.
The frame is painted structural steel, made to EN 15085 and designed to EN 12663. Reference standards include EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50463-2 / IEC 62888-2 and EN 50125 / IEC 62498. The insulation material follows EN 45545-2. The AC MODBOX range complements it with a compact aluminium enclosure for horizontal installation.
Technical specifications
| Type | Integrated roof frame for high voltage equipment |
|---|---|
| AC applications | 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz) |
| DC applications (AC/DC vehicles) | 1.5 kVDC and/or 3 kVDC |
| Thermal current | up to 630 A (AC) and 2600 A (DC) |
| Height above roof | ≤ 545 mm |
| Installation | roof installation in open air |
| Frame manufacture | EN 15085; designed to EN 12663 |
| Reference standards | EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50463-2 / IEC 62888-2, EN 50125 / IEC 62498 |
| Insulation material | according to EN 45545-2 |
How it compares with similar models
| Parameter | AC MODFRAME integrated roof frame for AC rail vehicles, up to 630 A (AC) | AC & DC MODBOX high-voltage integrated enclosure for rail vehicles, 1.5 kVDC to 25 kVAC | RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A | Metal oxide surge arresters for AC and DC rail vehicles, 10 kA / 20 kA |
|---|---|---|---|---|
| Type | Integrated roof frame for high voltage equipment | High-voltage integrated enclosure for rail vehicles | Roof-mounted disconnectors | Metal oxide surge arrester for railway vehicles |
| Installation | roof installation in open air | roof, indoor or under-frame | — | indoor or roof outdoor; vertical and horizontal |
| Reference standards | EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50463-2 / IEC 62888-2, EN 50125 / IEC 62498 | EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50125 / IEC 62498 | IEC 60077-2 | IEC 60099-4 (AC); EN 50526-1 (DC) |
Request a price and lead time
AC MODFRAME integrated roof frame for AC rail vehicles, up to 630 A (AC). We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which functions are integrated in the AC MODFRAME?
An AC circuit breaker, earthing device, voltage detection, voltage and current measurement, roof disconnectors, voltage selector and surge arresters.
Does the frame need a roof cut-out?
No, only if manual operation is selected for the earthing device.
How high is the frame above the roof?
545 mm or less.