RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A

RS roof-mounted disconnectors for AC and DC rail vehicles come as disconnector, disconnector with earthing, or change-over. The current range is 1000 to 4000 A, rated insulation is 27.5 kVAC or 4.8 kVDC, and operation is electric.

Type
Roof-mounted disconnectors
Executions
disconnector, disconnector & earthing, change-over
AC applications
15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz)
DC applications
1.5 kVDC and/or 3 kVDC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Car builders, traction equipment manufacturers and train operators know RS-type roof-mounted disconnectors for low maintenance. The platform has many configurations and options for most railway applications. Executions are disconnector, disconnector and earthing, and change-over. Products cover pantograph disconnectors with or without earthing, AC/DC traction selection for multi-system vehicles, and roof line disconnectors with or without making capability to connect or isolate traction transformers from the supply.

AC applications are 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz); DC applications are 1.5 kVDC and/or 3 kVDC. The current range is 1000 to 4000 A and rated insulation is 27.5 kVAC or 4.8 kVDC, with a high insulation level, OV4, against earth. The short-time withstand current is high and adapted to operational needs. There is no breaking capacity, but an optional making capacity of 800 A (AC) exists on a specific execution.

Operation is electric, with a control voltage of 24 to 220 VDC. Auxiliary contacts show the main contact position, and mechanical durability is high. Ambient temperature is – 40°C to +70°C, or -50°C to +70°C as an option.

A disconnector can be delivered stand-alone or integrated into a MACS AC circuit breaker. An indoor IS version can be integrated into a MODBOX enclosure. Options include a version for vehicles with no roof cut-out and one for making on inrush current. The reference standard is IEC 60077-2, and the insulation material follows EN 45545-2.

Technical specifications

TypeRoof-mounted disconnectors
Executionsdisconnector, disconnector & earthing, change-over
AC applications15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz)
DC applications1.5 kVDC and/or 3 kVDC
Current range1000 - 4000 A
Rated insulation27.5 kVAC or 4.8 kVDC
Insulation level against earthOV4
Making capacity (option)800 A (AC), specific execution
Operationelectric
Control voltage24 - 220 VDC
Ambient temperature– 40°C - +70°C (option: -50°C - +70°C)
Reference standardsIEC 60077-2
Insulation materialaccording to EN 45545-2

How it compares with similar models

ParameterRS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 AXMS and BW indoor disconnectors for rail vehicles, 4000 VAC/DC insulationBTE earthing switches and the MACS integrated earthing device for rail vehicles, up to 27.5 kVACAC & DC MODBOX high-voltage integrated enclosure for rail vehicles, 1.5 kVDC to 25 kVAC
TypeRoof-mounted disconnectorsModular indoor disconnectorsEarthing devices for high-voltage circuitsHigh-voltage integrated enclosure for rail vehicles
Control voltage24 - 220 VDC24 - 220 VDC24 - 110 VDC—
Ambient temperature– 40°C - +70°C (option: -50°C - +70°C)– 40 °C - +70 °C– 40 °C - +70 °C—
Reference standardsIEC 60077-2IEC 60077-2 (XMS), IEC77 (BW)IEC 60077-2EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50125 / IEC 62498

Request a price and lead time

RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which executions does the RS series have?

Disconnector, disconnector with earthing, and change-over.

Does the RS have breaking capacity?

No. An optional making capacity of 800 A (AC) exists on a specific execution.

What control voltage does the drive use?

24 to 220 VDC, with electric operation.