
RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A
RS roof-mounted disconnectors for AC and DC rail vehicles come as disconnector, disconnector with earthing, or change-over. The current range is 1000 to 4000 A, rated insulation is 27.5 kVAC or 4.8 kVDC, and operation is electric.
- Type
- Roof-mounted disconnectors
- Executions
- disconnector, disconnector & earthing, change-over
- AC applications
- 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz)
- DC applications
- 1.5 kVDC and/or 3 kVDC
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Car builders, traction equipment manufacturers and train operators know RS-type roof-mounted disconnectors for low maintenance. The platform has many configurations and options for most railway applications. Executions are disconnector, disconnector and earthing, and change-over. Products cover pantograph disconnectors with or without earthing, AC/DC traction selection for multi-system vehicles, and roof line disconnectors with or without making capability to connect or isolate traction transformers from the supply.
AC applications are 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz); DC applications are 1.5 kVDC and/or 3 kVDC. The current range is 1000 to 4000 A and rated insulation is 27.5 kVAC or 4.8 kVDC, with a high insulation level, OV4, against earth. The short-time withstand current is high and adapted to operational needs. There is no breaking capacity, but an optional making capacity of 800 A (AC) exists on a specific execution.
Operation is electric, with a control voltage of 24 to 220 VDC. Auxiliary contacts show the main contact position, and mechanical durability is high. Ambient temperature is – 40°C to +70°C, or -50°C to +70°C as an option.
A disconnector can be delivered stand-alone or integrated into a MACS AC circuit breaker. An indoor IS version can be integrated into a MODBOX enclosure. Options include a version for vehicles with no roof cut-out and one for making on inrush current. The reference standard is IEC 60077-2, and the insulation material follows EN 45545-2.
Technical specifications
| Type | Roof-mounted disconnectors |
|---|---|
| Executions | disconnector, disconnector & earthing, change-over |
| AC applications | 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz) |
| DC applications | 1.5 kVDC and/or 3 kVDC |
| Current range | 1000 - 4000 A |
| Rated insulation | 27.5 kVAC or 4.8 kVDC |
| Insulation level against earth | OV4 |
| Making capacity (option) | 800 A (AC), specific execution |
| Operation | electric |
| Control voltage | 24 - 220 VDC |
| Ambient temperature | – 40°C - +70°C (option: -50°C - +70°C) |
| Reference standards | IEC 60077-2 |
| Insulation material | according to EN 45545-2 |
How it compares with similar models
| Parameter | RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A | XMS and BW indoor disconnectors for rail vehicles, 4000 VAC/DC insulation | BTE earthing switches and the MACS integrated earthing device for rail vehicles, up to 27.5 kVAC | AC & DC MODBOX high-voltage integrated enclosure for rail vehicles, 1.5 kVDC to 25 kVAC |
|---|---|---|---|---|
| Type | Roof-mounted disconnectors | Modular indoor disconnectors | Earthing devices for high-voltage circuits | High-voltage integrated enclosure for rail vehicles |
| Control voltage | 24 - 220 VDC | 24 - 220 VDC | 24 - 110 VDC | — |
| Ambient temperature | – 40°C - +70°C (option: -50°C - +70°C) | – 40 °C - +70 °C | – 40 °C - +70 °C | — |
| Reference standards | IEC 60077-2 | IEC 60077-2 (XMS), IEC77 (BW) | IEC 60077-2 | EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50125 / IEC 62498 |
Request a price and lead time
RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which executions does the RS series have?
Disconnector, disconnector with earthing, and change-over.
Does the RS have breaking capacity?
No. An optional making capacity of 800 A (AC) exists on a specific execution.
What control voltage does the drive use?
24 to 220 VDC, with electric operation.
Similar equipment from other manufacturers






