SW disconnectors for fixed DC installations, 2000–8000 A
SW-type off-load disconnectors isolate the equipment that powers the overhead lines and third rails of DC mass transit and DC railways. Rated insulation voltage is 3000 or 4800 VAC/DC, the current range is 2000 A to 8000 A, and peak short-time withstand current is 170 kA.
- Type
- Off-load disconnector for fixed installation
- Executions
- disconnector, disconnector & earthing, change-over
- Rated insulation voltage
- 3000 or 4800 VAC/DC
- Current range
- 2000 A - 8000 A
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SW-type off-load disconnector is built for the safe isolation of equipment powering the overhead lines and third rails of DC mass transit (metro, Light Rail Vehicles, tramways, EMU trains) and DC railway lines. It comes in many configurations and with optional features to cover railway applications.
In fixed installations the disconnector is integrated into disconnector panels. It serves as the rectifier incoming or negative disconnector, the feeder cable disconnector, the by-pass disconnector, or a disconnector with earthing. Executions are disconnector, disconnector and earthing, and change-over, in 1 or 2 pole versions.
Rated insulation voltage is 3000 or 4800 VAC/DC, the current range is 2000 A to 8000 A and the peak short-time withstand current is 170 kA. The insulation level is high, OV4, and there is no breaking or making capacity. Operation is electric, with a control voltage of 24 to 220 VDC or 230 VAC.
Electro-magnet or key interlockings are optional and protect people. Auxiliary contacts indicate the main contact position, mechanical durability is high, and installation is indoors. The ambient temperature range is – 25 °C to +40 °C. Reference standards are EN 50123-3 and IEC 61992-3. Further applications include e-mining truck electrification, energy storage and rolling mills.
Technical specifications
| Type | Off-load disconnector for fixed installation |
|---|---|
| Executions | disconnector, disconnector & earthing, change-over |
| Rated insulation voltage | 3000 or 4800 VAC/DC |
| Current range | 2000 A - 8000 A |
| Peak short-time withstand current | 170 kA |
| Insulation level | OV4 |
| Pole versions | 1 or 2 |
| Control voltage | 24 - 220 VDC or 230 VAC |
| Installation | indoor |
| Ambient temperature | – 25 °C - +40 °C |
| Reference standards | EN 50123-3; IEC 61992-3 |
How it compares with similar models
| Parameter | SW disconnectors for fixed DC installations, 2000–8000 A | UR DC circuit breakers for traction substations to IEEE standards, 800–1600 VDC | UR DC circuit breakers for traction substations to EN/IEC standards, 900–3600 VDC | UR DC circuit breakers for industry, 900–3600 VDC, up to 8000 A |
|---|---|---|---|---|
| Type | Off-load disconnector for fixed installation | IEEE DC high-speed circuit breaker | DC high-speed circuit breaker for traction substations | Industrial DC high-speed circuit breaker |
| Current range | 2000 A - 8000 A | 2000 A - 8000 A | 1000 A - 8000 A | 1000 A - 8000 A |
| Control voltage | 24 - 220 VDC or 230 VAC | 110 VDC or 125 VDC | 24 - 220 VDC or rectified 230 VAC | 24 - 220 VDC or rectified 230 VAC |
| Reference standards | EN 50123-3; IEC 61992-3 | IEEE C37.16; IEEE C37.14 | EN 50123-2; IEC 61992-2 | IEC 60947-2; EN 50123-2; IEC 61992-2; GB 14048-2; ANSI C37.16; ANSI C37.14 |
Request a price and lead time
SW disconnectors for fixed DC installations, 2000–8000 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Does the SW have making or breaking capacity?
No. It is an off-load disconnector.
What current and insulation ratings apply?
2000 A to 8000 A, 3000 or 4800 VAC/DC insulation and 170 kA peak short-time withstand current.
Are interlockings available for personnel safety?
Yes, electro-magnet or key interlockings are optional.