UR DC circuit breakers for traction substations to IEEE standards, 800–1600 VDC

UR-type DC high-speed circuit breakers (HSCB) built to IEEE standards for DC traction power substations. Rated voltage is 800 VDC and 1600 VDC (1200 VDC for UR80), the current range is 2000 A to 8000 A, and control voltage is 110 VDC or 125 VDC.

Type
IEEE DC high-speed circuit breaker
Rated voltage
800 VDC and 1600 VDC (1200 VDC for UR80)
Current range
2000 A - 8000 A
Control voltage
110 VDC or 125 VDC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

This is the IEEE version of the UR breaker for DC traction power substations feeding overhead lines and third rails of metro, light rail, tramway, EMU and DC railway systems. The range is designed to IEEE C37.14 and IEEE C.37.16 and can be used for Light Rail and Heavy Rail Transit Systems in North America.

A breaker can be integrated into DC switchgear or a metal-clad enclosure configured as a line feeder panel, a rectifier breaker panel or an interconnecting breaker panel.

Rated voltage is 800 VDC and 1600 VDC, or 1200 VDC for the UR80, and the current range is 2000 A to 8000 A. The device is bi-directional or uni-directional, trip free and direct acting; making and breaking capacity matches operational needs and closing is electromagnetic. Control voltage is 110 VDC or 125 VDC.

Auxiliary contacts indicate the main contact position, and arc voltage during current interruption is constant and limited. The insulation level is high, OV4, and the ambient temperature range is – 25 °C to +40 °C.

Reference standards are IEEE C37.16 and IEEE C37.14; the insulation material follows EN 45545-2. A UR26-80S IEEE version exists.

Technical specifications

TypeIEEE DC high-speed circuit breaker
Rated voltage800 VDC and 1600 VDC (1200 VDC for UR80)
Current range2000 A - 8000 A
Control voltage110 VDC or 125 VDC
Insulation levelOV4
Ambient temperature– 25 °C - +40 °C
Reference standardsIEEE C37.16; IEEE C37.14
Insulation materialaccording to EN 45545-2

How it compares with similar models

ParameterUR DC circuit breakers for traction substations to IEEE standards, 800–1600 VDCUR DC circuit breakers for traction substations to EN/IEC standards, 900–3600 VDCUR DC circuit breakers for industry, 900–3600 VDC, up to 8000 ASW disconnectors for fixed DC installations, 2000–8000 A
TypeIEEE DC high-speed circuit breakerDC high-speed circuit breaker for traction substationsIndustrial DC high-speed circuit breakerOff-load disconnector for fixed installation
Rated voltage800 VDC and 1600 VDC (1200 VDC for UR80)900 VDC, 1800 VDC, 3600 VDC900 VDC, 1800 VDC, 3600 VDC—
Current range2000 A - 8000 A1000 A - 8000 A1000 A - 8000 A2000 A - 8000 A
Control voltage110 VDC or 125 VDC24 - 220 VDC or rectified 230 VAC24 - 220 VDC or rectified 230 VAC24 - 220 VDC or 230 VAC
Reference standardsIEEE C37.16; IEEE C37.14EN 50123-2; IEC 61992-2IEC 60947-2; EN 50123-2; IEC 61992-2; GB 14048-2; ANSI C37.16; ANSI C37.14EN 50123-3; IEC 61992-3

Request a price and lead time

UR DC circuit breakers for traction substations to IEEE standards, 800–1600 VDC. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which voltages does the IEEE version cover?

800 VDC and 1600 VDC, and 1200 VDC for the UR80.

What control voltage applies?

110 VDC or 125 VDC.

Which IEEE standards apply?

IEEE C37.16 and IEEE C37.14.