BMS, SEC and HS power contactors for DC and AC, 900–3600 V, 20–1800 A
BMS, SEC and HS power contactors switch DC circuits and AC circuits up to 400 Hz. Rated voltage is 900 VDC/VAC, 1800 VDC, 2000VAC or 3600 VDC/AC, the current range is 20 A to 1800 A, and control voltage is 24 to 220 VDC.
- Type
- Power contactor for DC and AC
- Rated voltage
- 900 VDC/VAC; 1800 VDC; 2000VAC; 3600 VDC/AC
- Current range
- 20 A - 1800 A
- AC voltages
- up to 4000 Vrms, up to 400 Hz
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
These contactors switch circuits in power converters, rail vehicles, traction converters and inverters, PMSM motors, e-buses and e-trucks, marine vessels, DC traction power substations, energy storage systems and EV battery fast charging stations. They are configured as line contactors, converter switches, permanent-magnet synchronous motor (PMSM) switches, traction circuit reconfiguration contactors, charging contactors, HVAC switches and auxiliary circuit isolating switches. The BMS range can be coupled mechanically and electrically to the PCC18 charging contactor, and BMS09 and BMS18 can be delivered with the PCC18 integrated.
They are used on DC, or on AC up to 400 Hz, with 1, 2 or 3 poles (synchronised or independent). Rated voltage is 900 VDC/VAC, 1800 VDC, 2000VAC or 3600 VDC/AC, and the current range is 20 A to 1800 A. DC voltages reach 3600 VDC and AC voltages reach 4000 Vrms at 400 Hz. Making and breaking capacity matches operational needs, and short-time withstand currents are adapted to the application.
Closing is electromagnetic and control voltage is 24 to 220 VDC. Auxiliary contacts indicate the main contact position. The operational frequency runs from C1 (light duty) to C3 (heavy duty). Interruption of low currents is handled well, and AC versions have a smaller arc chute. Installation is vertical or horizontal in ambient temperatures of – 40°C to +70°C.
Reference standards are IEC 60077-2, EN 50567 and IEC 61373, and the insulation material follows EN 45545-2. Contactors are delivered stand-alone, as modules for the customer's own line breaker and converter boxes, or inside MODBOX high-voltage enclosures.
Technical specifications
| Type | Power contactor for DC and AC |
|---|---|
| Rated voltage | 900 VDC/VAC; 1800 VDC; 2000VAC; 3600 VDC/AC |
| Current range | 20 A - 1800 A |
| AC voltages | up to 4000 Vrms, up to 400 Hz |
| Number of poles | 1, 2 or 3 |
| Control voltage | 24 - 220 VDC |
| Closing | electromagnetic |
| Operational frequency | C1 (light duty) - C3 (heavy duty) |
| Installation | vertical and horizontal |
| Ambient temperature | – 40°C - +70°C |
| Reference standards | IEC 60077-2, EN 50567, IEC 61373 |
| Insulation material | according to EN 45545-2 |
How it compares with similar models
| Parameter | BMS, SEC and HS power contactors for DC and AC, 900–3600 V, 20–1800 A | UR DC high-speed circuit breakers for rail vehicles, 900–3600 V | UR DC circuit breakers for traction substations to EN/IEC standards, 900–3600 VDC | UR DC circuit breakers for industry, 900–3600 VDC, up to 8000 A |
|---|---|---|---|---|
| Type | Power contactor for DC and AC | DC high-speed circuit breaker for rail vehicles | DC high-speed circuit breaker for traction substations | Industrial DC high-speed circuit breaker |
| Rated voltage | 900 VDC/VAC; 1800 VDC; 2000VAC; 3600 VDC/AC | 900 V, 1800 V, 3600 V | 900 VDC, 1800 VDC, 3600 VDC | 900 VDC, 1800 VDC, 3600 VDC |
| Current range | 20 A - 1800 A | 1000 A - 4000 A | 1000 A - 8000 A | 1000 A - 8000 A |
| Control voltage | 24 - 220 VDC | 24 - 110 VDC | 24 - 220 VDC or rectified 230 VAC | 24 - 220 VDC or rectified 230 VAC |
| Ambient temperature | – 40°C - +70°C | – 25 °C - +70 °C (option: -50 °C - +55 °C) | – 25 °C - +40 °C | – 25 °C - +40 °C |
| Reference standards | IEC 60077-2, EN 50567, IEC 61373 | IEC 60077-3 | EN 50123-2; IEC 61992-2 | IEC 60947-2; EN 50123-2; IEC 61992-2; GB 14048-2; ANSI C37.16; ANSI C37.14 |
Request a price and lead time
BMS, SEC and HS power contactors for DC and AC, 900–3600 V, 20–1800 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What current and voltage ratings do the contactors have?
20 A to 1800 A, at 900 VDC/VAC, 1800 VDC, 2000VAC or 3600 VDC/AC.
Can the contactors be used on AC?
Yes, on AC up to 400 Hz and voltages up to 4000 Vrms.
Can a BMS be combined with a charging contactor?
Yes, BMS couples to the PCC18 charging contactor, and BMS09 and BMS18 can be delivered with the PCC18 integrated.
Similar equipment from other manufacturers