International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

UR DC circuit breakers for industry, 900–3600 VDC, up to 8000 A

UR-type DC high-speed circuit breakers (HSCB) protect DC drives and converters in energy-intensive industry, renewable generation and energy storage. Rated voltages are 900 VDC, 1800 VDC and 3600 VDC, with a current range of 1000 A to 8000 A.

Type
Industrial DC high-speed circuit breaker
Rated voltage
900 VDC, 1800 VDC, 3600 VDC
Current range
1000 A - 8000 A
Control voltage
24 - 220 VDC or rectified 230 VAC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Outside the railway, UR breakers power and protect DC drives in energy-intensive industries and smart grid systems that include renewable energy production and storage. Typical uses are converters for renewable generation and storage, DC drives for steel and paper plants, static excitation systems of power plant generators, electric mining haul truck drives and marine vessel cycloconverters. Further applications are hydrogen production by electrolysis, windmills, energy storage, rolling mills, hydropower, solar farms and data centres.

Breakers are delivered on a stand-alone basis for integration into the customer's DC switchgear or metal-clad enclosure.

Rated voltage is 900 VDC, 1800 VDC or 3600 VDC and the current range is 1000 A to 8000 A. The device is bi-directional or uni-directional, trip free and direct acting; making and breaking capacity matches operational needs, and closing is electromagnetic. Control voltage is 24 to 220 VDC or rectified 230 VAC. Auxiliary contacts indicate the main contact position, and arc voltage during current interruption is constant and limited.

The suitable ambient temperature range is – 25 °C to +40 °C. Reference standards are IEC 60947-2, EN 50123-2, IEC 61992-2, GB 14048-2, ANSI C37.16 and ANSI C37.14. The insulation material follows EN 45545-2, and a UR26-80I version exists.

Technical specifications

TypeIndustrial DC high-speed circuit breaker
Rated voltage900 VDC, 1800 VDC, 3600 VDC
Current range1000 A - 8000 A
Control voltage24 - 220 VDC or rectified 230 VAC
Ambient temperature– 25 °C - +40 °C
Reference standardsIEC 60947-2; EN 50123-2; IEC 61992-2; GB 14048-2; ANSI C37.16; ANSI C37.14
Insulation materialaccording to EN 45545-2

How it compares with similar models

ParameterUR DC circuit breakers for industry, 900–3600 VDC, up to 8000 AUR DC circuit breakers for traction substations to EN/IEC standards, 900–3600 VDCUR DC circuit breakers for traction substations to IEEE standards, 800–1600 VDCUR DC high-speed circuit breakers for rail vehicles, 900–3600 V
TypeIndustrial DC high-speed circuit breakerDC high-speed circuit breaker for traction substationsIEEE DC high-speed circuit breakerDC high-speed circuit breaker for rail vehicles
Rated voltage900 VDC, 1800 VDC, 3600 VDC900 VDC, 1800 VDC, 3600 VDC800 VDC and 1600 VDC (1200 VDC for UR80)900 V, 1800 V, 3600 V
Current range1000 A - 8000 A1000 A - 8000 A2000 A - 8000 A1000 A - 4000 A
Control voltage24 - 220 VDC or rectified 230 VAC24 - 220 VDC or rectified 230 VAC110 VDC or 125 VDC24 - 110 VDC
Ambient temperature– 25 °C - +40 °C– 25 °C - +40 °C– 25 °C - +40 °C– 25 °C - +70 °C (option: -50 °C - +55 °C)
Reference standardsIEC 60947-2; EN 50123-2; IEC 61992-2; GB 14048-2; ANSI C37.16; ANSI C37.14EN 50123-2; IEC 61992-2IEEE C37.16; IEEE C37.14IEC 60077-3

Request a price and lead time

UR DC circuit breakers for industry, 900–3600 VDC, up to 8000 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which industrial drives are the UR breakers used for?

DC drives for steel and paper plants, rolling mills, electric mining haul truck drives, generator excitation systems and others.

What voltage and current ratings are offered?

900 VDC, 1800 VDC or 3600 VDC, with 1000 A to 8000 A.

How are the breakers delivered?

On a stand-alone basis, for integration into the customer's DC switchgear or metal-clad enclosure.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides