UR DC circuit breakers for industry, 900–3600 VDC, up to 8000 A
UR-type DC high-speed circuit breakers (HSCB) protect DC drives and converters in energy-intensive industry, renewable generation and energy storage. Rated voltages are 900 VDC, 1800 VDC and 3600 VDC, with a current range of 1000 A to 8000 A.
- Type
- Industrial DC high-speed circuit breaker
- Rated voltage
- 900 VDC, 1800 VDC, 3600 VDC
- Current range
- 1000 A - 8000 A
- Control voltage
- 24 - 220 VDC or rectified 230 VAC
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Outside the railway, UR breakers power and protect DC drives in energy-intensive industries and smart grid systems that include renewable energy production and storage. Typical uses are converters for renewable generation and storage, DC drives for steel and paper plants, static excitation systems of power plant generators, electric mining haul truck drives and marine vessel cycloconverters. Further applications are hydrogen production by electrolysis, windmills, energy storage, rolling mills, hydropower, solar farms and data centres.
Breakers are delivered on a stand-alone basis for integration into the customer's DC switchgear or metal-clad enclosure.
Rated voltage is 900 VDC, 1800 VDC or 3600 VDC and the current range is 1000 A to 8000 A. The device is bi-directional or uni-directional, trip free and direct acting; making and breaking capacity matches operational needs, and closing is electromagnetic. Control voltage is 24 to 220 VDC or rectified 230 VAC. Auxiliary contacts indicate the main contact position, and arc voltage during current interruption is constant and limited.
The suitable ambient temperature range is – 25 °C to +40 °C. Reference standards are IEC 60947-2, EN 50123-2, IEC 61992-2, GB 14048-2, ANSI C37.16 and ANSI C37.14. The insulation material follows EN 45545-2, and a UR26-80I version exists.
Technical specifications
| Type | Industrial DC high-speed circuit breaker |
|---|---|
| Rated voltage | 900 VDC, 1800 VDC, 3600 VDC |
| Current range | 1000 A - 8000 A |
| Control voltage | 24 - 220 VDC or rectified 230 VAC |
| Ambient temperature | – 25 °C - +40 °C |
| Reference standards | IEC 60947-2; EN 50123-2; IEC 61992-2; GB 14048-2; ANSI C37.16; ANSI C37.14 |
| Insulation material | according to EN 45545-2 |
How it compares with similar models
| Parameter | UR DC circuit breakers for industry, 900–3600 VDC, up to 8000 A | UR DC circuit breakers for traction substations to EN/IEC standards, 900–3600 VDC | UR DC circuit breakers for traction substations to IEEE standards, 800–1600 VDC | UR DC high-speed circuit breakers for rail vehicles, 900–3600 V |
|---|---|---|---|---|
| Type | Industrial DC high-speed circuit breaker | DC high-speed circuit breaker for traction substations | IEEE DC high-speed circuit breaker | DC high-speed circuit breaker for rail vehicles |
| Rated voltage | 900 VDC, 1800 VDC, 3600 VDC | 900 VDC, 1800 VDC, 3600 VDC | 800 VDC and 1600 VDC (1200 VDC for UR80) | 900 V, 1800 V, 3600 V |
| Current range | 1000 A - 8000 A | 1000 A - 8000 A | 2000 A - 8000 A | 1000 A - 4000 A |
| Control voltage | 24 - 220 VDC or rectified 230 VAC | 24 - 220 VDC or rectified 230 VAC | 110 VDC or 125 VDC | 24 - 110 VDC |
| Ambient temperature | – 25 °C - +40 °C | – 25 °C - +40 °C | – 25 °C - +40 °C | – 25 °C - +70 °C (option: -50 °C - +55 °C) |
| Reference standards | IEC 60947-2; EN 50123-2; IEC 61992-2; GB 14048-2; ANSI C37.16; ANSI C37.14 | EN 50123-2; IEC 61992-2 | IEEE C37.16; IEEE C37.14 | IEC 60077-3 |
Request a price and lead time
UR DC circuit breakers for industry, 900–3600 VDC, up to 8000 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which industrial drives are the UR breakers used for?
DC drives for steel and paper plants, rolling mills, electric mining haul truck drives, generator excitation systems and others.
What voltage and current ratings are offered?
900 VDC, 1800 VDC or 3600 VDC, with 1000 A to 8000 A.
How are the breakers delivered?
On a stand-alone basis, for integration into the customer's DC switchgear or metal-clad enclosure.
Similar equipment from other manufacturers