XMS and BW indoor disconnectors for rail vehicles, 4000 VAC/DC insulation
XMS and BW are high-voltage modular indoor disconnectors for rail vehicles and other industrial applications. Rated insulation voltage is 4000 VAC/DC, current is up to 750 A (BW) or 1500 A (XMS), and control voltage is 24 to 220 VDC.
- Type
- Modular indoor disconnectors
- Rated insulation voltage
- 4000 VAC/DC
- Current range
- up to 750A (BW) or 1500 A (XMS)
- Pole versions (XMS)
- 1, 2 or 3-pole
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Use the XMS and BW as disconnectors or changeover devices on rail vehicles and in other industrial applications. The XMS can be configured as a single-pole pantograph disconnector for EMUs on 1.5 kVDC and/or 3.0 kVDC networks, as a single- or double-pole traction circuit reconfiguration device for multisystem vehicles, or as a 3-pole motor disconnector. It is delivered stand-alone or integrated into a MODBOX enclosure.
The BW is a multipole disconnector with a modular, linear design that takes different numbers of moving contacts and high-voltage terminals. It is mainly used to select or change the configuration of traction and/or auxiliary circuits.
Rated insulation voltage is 4000 VAC/DC and the current range is up to 750 A (BW) or 1500 A (XMS). The XMS comes in 1, 2 or 3-pole versions, and the BW takes up to 24 high voltage terminals (BWT) or 56 (BWU). Rated short-time withstand current is 20kA/50kA (BW) and 60kA (XMS). The BW has no making or breaking capacity; the XMS has reduced making and breaking capacities. XMS closing is electromagnetic, while the BW is operated electrically, electro-pneumatically or manually.
Control voltage is 24 to 220 VDC. XMS mechanical closing and opening time is under 100 ms, and BW switching time is 1 to 3 sec. Auxiliary contacts indicate the main contact position. Mounting is horizontal or vertical, and the ambient temperature range is – 40 °C to +70 °C. Reference standards are IEC 60077-2 (XMS) and IEC77 (BW), and the insulation material follows EN 45545-2.
Technical specifications
| Type | Modular indoor disconnectors |
|---|---|
| Rated insulation voltage | 4000 VAC/DC |
| Current range | up to 750A (BW) or 1500 A (XMS) |
| Pole versions (XMS) | 1, 2 or 3-pole |
| High voltage terminals | up to 24 (BWT) or 56 (BWU) |
| Rated short-time withstand current | 20kA/50kA (BW), 60kA (XMS) |
| Control voltage | 24 - 220 VDC |
| Mechanical closing and opening time (XMS) | < 100 ms |
| Switching time (BW) | 1 - 3 sec |
| Mounting | horizontal or vertical |
| Ambient temperature | – 40 °C - +70 °C |
| Reference standards | IEC 60077-2 (XMS), IEC77 (BW) |
| Insulation material | according to EN 45545-2 |
How it compares with similar models
| Parameter | XMS and BW indoor disconnectors for rail vehicles, 4000 VAC/DC insulation | RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A | BMS, SEC and HS power contactors for DC and AC, 900–3600 V, 20–1800 A | BTE earthing switches and the MACS integrated earthing device for rail vehicles, up to 27.5 kVAC |
|---|---|---|---|---|
| Type | Modular indoor disconnectors | Roof-mounted disconnectors | Power contactor for DC and AC | Earthing devices for high-voltage circuits |
| Current range | up to 750A (BW) or 1500 A (XMS) | 1000 - 4000 A | 20 A - 1800 A | — |
| Control voltage | 24 - 220 VDC | 24 - 220 VDC | 24 - 220 VDC | 24 - 110 VDC |
| Ambient temperature | – 40 °C - +70 °C | – 40°C - +70°C (option: -50°C - +70°C) | – 40°C - +70°C | – 40 °C - +70 °C |
| Reference standards | IEC 60077-2 (XMS), IEC77 (BW) | IEC 60077-2 | IEC 60077-2, EN 50567, IEC 61373 | IEC 60077-2 |
Request a price and lead time
XMS and BW indoor disconnectors for rail vehicles, 4000 VAC/DC insulation. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the XMS used for?
As a single-pole pantograph disconnector on 1.5 kVDC and/or 3.0 kVDC networks, a traction circuit reconfiguration device or a 3-pole motor disconnector.
How many terminals does the BW take?
Up to 24 high voltage terminals (BWT) or 56 (BWU).
How is the BW operated?
Electrically, electro-pneumatically or manually, with a switching time of 1 to 3 sec.