BTE earthing switches and the MACS integrated earthing device for rail vehicles, up to 27.5 kVAC
Earthing devices BTE15/25.04 and BTE03.04, plus the earthing integrated in the MACS circuit breaker, for high-voltage circuits on rail vehicles. Rated insulation voltage reaches 27.5 kVAC, peak short-time withstand current is 62.5 kA or 75 kA, and control voltage is 24 to 110 VDC.
- Type
- Earthing devices for high-voltage circuits
- Rated insulation voltage (MACS)
- 27.5 kVAC
- Rated insulation voltage (BTE15.04 / BTE25.04)
- 17.25 kVAC / 27.5 kVAC
- Rated insulation voltage (BTE03.04)
- 2300 VAC/DC or 4800 VAC/DC
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Earthing high-voltage circuits before maintenance is critical to keeping workers safe. On a rail vehicle the first step is to earth both poles of the main circuit breaker once it has been opened. On 15 kVAC and 25 kVAC vehicles the BVAC breaker is coupled with the BTE15/25.04, while the MACS breaker has integrated earthing. On DC vehicles up to 3 kVDC the UR breaker is coupled with the BTE03.04. When this step is done and the earthing switch interlocking key of the main breaker is released, the earthing device on the high-voltage circuits downline can be operated.
The BTE03.04 earths DC link circuits on AC vehicles and traction converter filters on AC and DC vehicles. On DC vehicles a single BTE03.04 can perform both earthing steps. It is delivered stand-alone or integrated into a MODBOX enclosure.
Rated insulation voltage is 27.5 kVAC for the MACS integrated earthing, 17.25 kVAC for the BTE15.04, 27.5 kVAC for the BTE25.04 and 2300 VAC/DC or 4800 VAC/DC for the BTE03.04. Peak short-time withstand current is 62.5 kA (BTE15/25.04 and MACS) or 75 kA (BTE03.04). The BTE15/25.04 and the MACS device have 2 poles; the BTE03.04 has 2 to 10. The insulation level against earth is OV4, and there is no breaking or making capacity.
Operation is manual or electric with a control voltage of 24 to 110 VDC, and interlockings are key or electric. Optional auxiliary switches show the switch position. The BTE15/25.04 and MACS device are installed outdoors, the BTE03.04 indoors. Ambient temperature is – 40 °C to +70 °C, the standard is IEC 60077-2 and the insulation material follows EN 45545-2.
Technical specifications
| Type | Earthing devices for high-voltage circuits |
|---|---|
| Rated insulation voltage (MACS) | 27.5 kVAC |
| Rated insulation voltage (BTE15.04 / BTE25.04) | 17.25 kVAC / 27.5 kVAC |
| Rated insulation voltage (BTE03.04) | 2300 VAC/DC or 4800 VAC/DC |
| Peak short-time withstand current (BTE15/25.04, MACS) | 62.5 kA |
| Peak short-time withstand current (BTE03.04) | 75 kA |
| Pole versions | 2 (BTE15/25.04, MACS); 2 to 10 (BTE03.04) |
| Insulation level against earth | OV4 |
| Control voltage | 24 - 110 VDC |
| Ambient temperature | – 40 °C - +70 °C |
| Reference standards | IEC 60077-2 |
| Insulation material | according to EN 45545-2 |
How it compares with similar models
| Parameter | BTE earthing switches and the MACS integrated earthing device for rail vehicles, up to 27.5 kVAC | RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A | XMS and BW indoor disconnectors for rail vehicles, 4000 VAC/DC insulation | MACS/BVAC AC vacuum circuit breakers for rail vehicles, 15/25 kV |
|---|---|---|---|---|
| Type | Earthing devices for high-voltage circuits | Roof-mounted disconnectors | Modular indoor disconnectors | AC vacuum circuit breaker for rail vehicles |
| Control voltage | 24 - 110 VDC | 24 - 220 VDC | 24 - 220 VDC | 24 - 110 VDC |
| Ambient temperature | – 40 °C - +70 °C | – 40°C - +70°C (option: -50°C - +70°C) | – 40 °C - +70 °C | – 40°C - +70°C (option: -50°C - +55°C) |
| Reference standards | IEC 60077-2 | IEC 60077-2 | IEC 60077-2 (XMS), IEC77 (BW) | IEC 60077-4 |
Request a price and lead time
BTE earthing switches and the MACS integrated earthing device for rail vehicles, up to 27.5 kVAC. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which earthing device is used on DC vehicles?
The UR breaker is coupled with the BTE03.04, and a single BTE03.04 can perform both earthing steps.
How many poles do the devices have?
The BTE15/25.04 and the MACS device have 2 poles; the BTE03.04 has 2 to 10.
How are the earthing devices operated?
Manually or electrically at 24 to 110 VDC, with key or electric interlockings.
Similar equipment from other manufacturers