AC & DC MODBOX high-voltage integrated enclosure for rail vehicles, 1.5 kVDC to 25 kVAC
The MODBOX is a compact enclosure that houses AC or DC circuit breakers and other high and low voltage components for vehicles on 1.5 kVDC, 3 kVDC, 15 kVAC and 25 kVAC networks. Thermal current is up to 630 A (AC) or 3200 A (DC), height above roof 545 mm or less.
- Type
- High-voltage integrated enclosure for rail vehicles
- AC applications
- 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz)
- DC applications
- 1.5 kVDC and/or 3 kVDC
- Thermal current
- up to 630 A (AC) or 3200 A (DC)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Each MODBOX is engineered and configured for the project it goes into. It includes the integrated functions and the interfaces with the vehicle, which makes it a turnkey unit that facilitates engineering, logistics, installation and operation. The enclosure is used on rail vehicles running on 1.5 kVDC, 3 kVDC, 15 kVAC and 25 kVAC networks.
Inside are AC or DC circuit breakers and various high and low voltage components. The manufacturer mainly uses its own components and can add devices from other suppliers. The compact enclosure can be installed on the roof, under the vehicle frame or indoors. Main integrated functions are a circuit breaker, surge arresters, current and voltage measurement, an earthing switch, a line disconnector, and line and charging contactors with a charging resistor.
AC applications are 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz), and DC applications are 1.5 kVDC and/or 3 kVDC. Thermal current is up to 630 A (AC) or 3200 A (DC), and the height above the roof is 545 mm or less.
For car builders the benefits are less engineering work and risk, more efficient logistics and installation, protection in severe environments, reduced noise and no need for roof cut-outs. Reference standards are EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4 and EN 50125 / IEC 62498. The insulation material follows EN 45545-2.
Technical specifications
| Type | High-voltage integrated enclosure for rail vehicles |
|---|---|
| AC applications | 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz) |
| DC applications | 1.5 kVDC and/or 3 kVDC |
| Thermal current | up to 630 A (AC) or 3200 A (DC) |
| Height above roof | ≤ 545 mm |
| Installation | roof, indoor or under-frame |
| Integrated functions | circuit-breaker, surge arresters, current and voltage measurements, earthing switch, line disconnector, line and charging contactors with charging resistor |
| Reference standards | EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50125 / IEC 62498 |
| Insulation material | according to EN 45545-2 |
How it compares with similar models
| Parameter | AC & DC MODBOX high-voltage integrated enclosure for rail vehicles, 1.5 kVDC to 25 kVAC | AC MODFRAME integrated roof frame for AC rail vehicles, up to 630 A (AC) | RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A | Metal oxide surge arresters for AC and DC rail vehicles, 10 kA / 20 kA |
|---|---|---|---|---|
| Type | High-voltage integrated enclosure for rail vehicles | Integrated roof frame for high voltage equipment | Roof-mounted disconnectors | Metal oxide surge arrester for railway vehicles |
| Installation | roof, indoor or under-frame | roof installation in open air | — | indoor or roof outdoor; vertical and horizontal |
| Reference standards | EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50125 / IEC 62498 | EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50463-2 / IEC 62888-2, EN 50125 / IEC 62498 | IEC 60077-2 | IEC 60099-4 (AC); EN 50526-1 (DC) |
Request a price and lead time
AC & DC MODBOX high-voltage integrated enclosure for rail vehicles, 1.5 kVDC to 25 kVAC. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which functions can a MODBOX integrate?
A circuit breaker, surge arresters, current and voltage measurement, an earthing switch, a line disconnector, and line and charging contactors.
Where can the MODBOX be installed?
On the roof, under the vehicle frame or indoors, with a height above the roof of 545 mm or less.
Which networks is the MODBOX made for?
1.5 kVDC, 3 kVDC, 15 kVAC and 25 kVAC.