Metal oxide surge arresters for AC and DC rail vehicles, 10 kA / 20 kA
Metal oxide surge arresters with external silicon insulation protect AC and DC railway vehicles from lightning and switching overvoltages. Nominal discharge current is 10 kA or 20 kA, high current impulse is 100 kA, and outdoor versions are available for speeds up to 360 km/h.
- Type
- Metal oxide surge arrester for railway vehicles
- External insulation
- silicon
- AC applications
- 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz)
- DC applications
- 1.5 kVDC and/or 3 kVDC
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Two positions are recommended for the arresters. A first arrester (SA1) goes immediately after the pantograph on AC and DC railway vehicles to deal with lightning and switching overvoltages. On AC vehicles a second arrester (SA2) sits between the main AC vacuum circuit breaker and the traction transformer. Its job is to protect the high-voltage circuits from surges caused by current chopping, which occurs when the vacuum interrupter breaks low magnetisation currents.
The arrester is of the metal oxide type with external silicon insulation. AC applications are 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz), and DC applications are 1.5 kVDC and/or 3 kVDC. Nominal discharge current is 10 kA or 20 kA, and the high current impulse is 100 kA.
Versions exist for indoor installation or outdoor installation on the roof, and an outdoor configuration is available for speeds up to 360 km/h. Mounting is vertical or horizontal, and the ambient temperature range is – 40°C to +70°C.
Arresters can be integrated into MACS AC circuit breakers or built into MODBOX high-voltage enclosures. Reference standards are IEC 60099-4 for AC and EN 50526-1 for DC, and the insulation material follows EN 45545-2.
Technical specifications
| Type | Metal oxide surge arrester for railway vehicles |
|---|---|
| External insulation | silicon |
| AC applications | 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz) |
| DC applications | 1.5 kVDC and/or 3 kVDC |
| Nominal discharge current | 10 kA or 20 kA |
| High current impulse | 100 kA |
| Installation | indoor or roof outdoor; vertical and horizontal |
| Max. speed (outdoor) | 360 km/h |
| Ambient temperature | – 40°C - +70°C |
| Reference standards | IEC 60099-4 (AC); EN 50526-1 (DC) |
How it compares with similar models
| Parameter | Metal oxide surge arresters for AC and DC rail vehicles, 10 kA / 20 kA | AC & DC MODBOX high-voltage integrated enclosure for rail vehicles, 1.5 kVDC to 25 kVAC | RS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 A | AC MODFRAME integrated roof frame for AC rail vehicles, up to 630 A (AC) |
|---|---|---|---|---|
| Type | Metal oxide surge arrester for railway vehicles | High-voltage integrated enclosure for rail vehicles | Roof-mounted disconnectors | Integrated roof frame for high voltage equipment |
| Installation | indoor or roof outdoor; vertical and horizontal | roof, indoor or under-frame | — | roof installation in open air |
| Reference standards | IEC 60099-4 (AC); EN 50526-1 (DC) | EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50125 / IEC 62498 | IEC 60077-2 | EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50463-2 / IEC 62888-2, EN 50125 / IEC 62498 |
Request a price and lead time
Metal oxide surge arresters for AC and DC rail vehicles, 10 kA / 20 kA. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Where are the SA1 and SA2 arresters installed?
SA1 goes immediately after the pantograph; on AC vehicles SA2 goes between the main AC vacuum circuit breaker and the traction transformer.
What are the discharge current and impulse ratings?
Nominal discharge current is 10 kA or 20 kA and the high current impulse is 100 kA.
Is there a version for high speeds?
Yes, an outdoor configuration is available for speeds up to 360 km/h.
Similar equipment from other manufacturers