International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Metal oxide surge arresters for AC and DC rail vehicles, 10 kA / 20 kA

Metal oxide surge arresters with external silicon insulation protect AC and DC railway vehicles from lightning and switching overvoltages. Nominal discharge current is 10 kA or 20 kA, high current impulse is 100 kA, and outdoor versions are available for speeds up to 360 km/h.

Type
Metal oxide surge arrester for railway vehicles
External insulation
silicon
AC applications
15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz)
DC applications
1.5 kVDC and/or 3 kVDC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Two positions are recommended for the arresters. A first arrester (SA1) goes immediately after the pantograph on AC and DC railway vehicles to deal with lightning and switching overvoltages. On AC vehicles a second arrester (SA2) sits between the main AC vacuum circuit breaker and the traction transformer. Its job is to protect the high-voltage circuits from surges caused by current chopping, which occurs when the vacuum interrupter breaks low magnetisation currents.

The arrester is of the metal oxide type with external silicon insulation. AC applications are 15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz), and DC applications are 1.5 kVDC and/or 3 kVDC. Nominal discharge current is 10 kA or 20 kA, and the high current impulse is 100 kA.

Versions exist for indoor installation or outdoor installation on the roof, and an outdoor configuration is available for speeds up to 360 km/h. Mounting is vertical or horizontal, and the ambient temperature range is – 40°C to +70°C.

Arresters can be integrated into MACS AC circuit breakers or built into MODBOX high-voltage enclosures. Reference standards are IEC 60099-4 for AC and EN 50526-1 for DC, and the insulation material follows EN 45545-2.

Technical specifications

TypeMetal oxide surge arrester for railway vehicles
External insulationsilicon
AC applications15 kV (16.7 Hz) and/or 25 kV (50 Hz or 60 Hz)
DC applications1.5 kVDC and/or 3 kVDC
Nominal discharge current10 kA or 20 kA
High current impulse100 kA
Installationindoor or roof outdoor; vertical and horizontal
Max. speed (outdoor)360 km/h
Ambient temperature– 40°C - +70°C
Reference standardsIEC 60099-4 (AC); EN 50526-1 (DC)

How it compares with similar models

ParameterMetal oxide surge arresters for AC and DC rail vehicles, 10 kA / 20 kAAC & DC MODBOX high-voltage integrated enclosure for rail vehicles, 1.5 kVDC to 25 kVACRS roof disconnectors for rail vehicles, 15/25 kV AC and 1.5/3 kVDC, 1000–4000 AAC MODFRAME integrated roof frame for AC rail vehicles, up to 630 A (AC)
TypeMetal oxide surge arrester for railway vehiclesHigh-voltage integrated enclosure for rail vehiclesRoof-mounted disconnectorsIntegrated roof frame for high voltage equipment
Installationindoor or roof outdoor; vertical and horizontalroof, indoor or under-frame—roof installation in open air
Reference standardsIEC 60099-4 (AC); EN 50526-1 (DC)EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50125 / IEC 62498IEC 60077-2EN 50124-1, IEC 62497-1, IEC 61373, IEC 60077-2, IEC 60077-3, IEC 60077-4, EN 50463-2 / IEC 62888-2, EN 50125 / IEC 62498

Request a price and lead time

Metal oxide surge arresters for AC and DC rail vehicles, 10 kA / 20 kA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Where are the SA1 and SA2 arresters installed?

SA1 goes immediately after the pantograph; on AC vehicles SA2 goes between the main AC vacuum circuit breaker and the traction transformer.

What are the discharge current and impulse ratings?

Nominal discharge current is 10 kA or 20 kA and the high current impulse is 100 kA.

Is there a version for high speeds?

Yes, an outdoor configuration is available for speeds up to 360 km/h.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides