PADS disconnect switch panels for DC traction substations
PADS (ESTRA-PADS) disconnect switch panels for DC disconnector cubicles, available for indoor and outdoor installation. Rated current is up to 8000 A and rated voltage 900 V, 1800 V or 3600 V.
- Product type
- DC disconnect switch panels (ESTRA-PADS)
- DC rated current
- up to 8000 A
- Rated voltage
- 900 V, 1800 V, 3600 V
- Poles
- 1 or 2
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
PADS disconnect switch panels belong to the ESTRA range and cover the disconnector cubicle needs of railway DC traction power substations. The integration includes SW-type offload disconnect switches. The panels are available for indoor and outdoor installation, and the range of configurations is virtually unlimited.
Several duties are covered. Indoor incoming switches isolate the high-voltage output of the rectifier groups from the feeder DC distribution bus. Indoor negative switches isolate the negative pole of the rectifier and can contain one or several single pole disconnectors. The indoor coupling switch subdivides the main busbar into separate sections. Outdoor and wayside switches include feeder isolating switches and over-area, intersection isolating switches.
The DC rated current is up to 8000 A and the rated voltage is 900 V, 1800 V or 3600 V. Panels have 1 or 2 poles. Variants include earthing in the open position and a change-over function. Control voltage runs from 24 to 220 VDC or 230 VAC, and short-time withstand currents are adapted to the application.
Reference standards are EN 50123-3 and IEC 61992-3, plus IEEE ANSI C37.20.1. The panels are type tested to EN 50123-3. Wayside cubicles come in metallic or polyester execution.
Optional electrical and mechanical interlocks and a key interlock mechanism support safe operation, and the low-voltage compartment can be segregated. The design is modular and highly configurable, with high mechanical and electrical durability and low maintenance. Typical uses are DC switchgear, indoor and outdoor DC distribution boards, railway DC traction power supply and e-mining truck electrification.
Technical specifications
| Product type | DC disconnect switch panels (ESTRA-PADS) |
|---|---|
| DC rated current | up to 8000 A |
| Rated voltage | 900 V, 1800 V, 3600 V |
| Poles | 1 or 2 |
| Control voltage | from 24 to 220 VDC, 230 VAC |
| Duties | indoor incoming, negative and coupling switches; outdoor and wayside switches |
| Variants | earthing in open position; change-over function |
| Interlocks | electrical and mechanical (optional), key interlock |
| Standards | EN 50123-3, IEC 61992-3, IEEE ANSI C37.20.1 |
How it compares with similar models
| Parameter | PADS disconnect switch panels for DC traction substations | PALB load break switch panels for DC traction substations | MBS high-speed circuit breaker panels for DC traction substations | VGUARD voltage limiting devices for railway DC traction |
|---|---|---|---|---|
| Product type | DC disconnect switch panels (ESTRA-PADS) | DC load break switch panels (ESTRA-PALB) | DC high-speed circuit breaker panels (ESTRA-MBS) | Voltage limiting device for railway DC traction (ESTRA-VGUARD) |
| DC rated current | up to 8000 A | up to 6000 A | up to 8000 A | — |
| Rated voltage | 900 V, 1800 V, 3600 V | 900 V, 1800 V, 3600 V | 900 V, 1800 V, 3600 V | up to 3600 V |
| Control voltage | from 24 to 220 VDC, 230 VAC | from 24 to 220 VDC | from 24 to 220 VDC, 230 VAC | from 24 to 220 VDC, 230 VAC |
| Standards | EN 50123-3, IEC 61992-3, IEEE ANSI C37.20.1 | EN 50123-3, IEC 61992-3 | EN 50123, IEC 61992, IEEE ANSI C37.20.1, C37.14 | EN 50122-1, EN 50526-2 |
Request a price and lead time
PADS disconnect switch panels for DC traction substations. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What are the rated current and voltage of the PADS panels?
The DC rated current is up to 8000 A and the rated voltage is 900 V, 1800 V or 3600 V.
How many poles do the panels have?
1 or 2 poles. Variants include earthing in the open position and a change-over function.
Are outdoor versions available?
Yes, outdoor and wayside switches include feeder isolating switches and over-area, intersection isolating switches.
Similar equipment from other manufacturers