KEOPS control command and local SCADA for traction substations
KEOPS (STELLA-KEOPS) gives an overview of a DC traction power substation and tools to control, configure and troubleshoot every device on the network. It interfaces with energy SCADA through the SEPCOS Gateway.
- Product type
- Local SCADA and control system for traction (STELLA-KEOPS)
- Display
- touch screen Panel PC, wide screen 15″6 or 18″6
- Interface
- energy SCADA, RTU by SEPCOS Gateway
- Communication protocols
- IEC 61850, IEC 60870-5-104 (101), DNP3, Modbus TCP, Profinet
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
KEOPS command, control and monitoring devices support the operation and maintenance of railway power supply networks. They give an at-a-glance overview of the substation and simple tools to control, configure and troubleshoot all devices on the network. Interfacing the substation supervision system with the overall line supervision is simple: different devices and protocols can be integrated and managed together or separately. Different network architectures are supported, including redundant and hot standby.
The operator interface is a touch screen Panel PC with a wide screen of 15″6 or 18″6. It is supplied in a dedicated cubicle or integrated into an existing one as a customised solution. Communication covers IEC 61850, IEC 60870-5-104 (101), DNP3, Modbus TCP, Profinet and more. The interface for energy SCADA is an RTU by SEPCOS Gateway.
Digital and analogue input-output modules control the equipment directly by wire. Manageable or standard ethernet switches are integrated, depending on the protocol used, together with a media converter for copper cable, optical fibre or various protocols. Synchronisation uses NTP, and network redundancy follows IEC 62439-3 (PRP/HSR).
Functions include visualisation of the complete substation, alarm and event management, a database and archive with an unlimited number of archives, hot standby with automated replication between active and standby server, web server technology, network monitoring, multilingualism and user administration. Intuitive controls and interlocks, configuration, diagnostics and long-term data logging are also covered.
Application is DC traction power supply for railways.
Technical specifications
| Product type | Local SCADA and control system for traction (STELLA-KEOPS) |
|---|---|
| Display | touch screen Panel PC, wide screen 15″6 or 18″6 |
| Interface | energy SCADA, RTU by SEPCOS Gateway |
| Communication protocols | IEC 61850, IEC 60870-5-104 (101), DNP3, Modbus TCP, Profinet |
| Network redundancy | IEC 62439-3, PRP/HSR |
| Synchronisation | NTP |
| Inputs/outputs | digital and analogue input-output modules |
| Media converter | copper cable / optical fibre or various protocols |
| Switches | manageable or standard ethernet switches, integrated |
| Standby | hot standby with automated replication |
| Supply form | dedicated cubicle or integration in an existing one |
Request a price and lead time
KEOPS control command and local SCADA for traction substations. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which communication protocols does KEOPS support?
IEC 61850, IEC 60870-5-104 (101), DNP3, Modbus TCP, Profinet and more.
How is redundancy handled?
Through network redundancy to IEC 62439-3 (PRP/HSR) and hot standby with automated replication between the active and standby server.
What display does the operator station have?
A touch screen Panel PC with a wide screen of 15″6 or 18″6.
Similar equipment from other manufacturers