International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Passenger car door operators (pneumatic and electric) and retractable steps

Door operators for passenger cars of electric multiple units and metros in pneumatic and electric versions, mounted above an opening 1300 mm wide. The closing force is 560 N. The set of devices includes a closing force relaxation controller and a retractable step that bridges the gap to the platform.

Pneumatic operator
cylinder + belt; 490 kPa; solenoid valve 100 or 24 V DC; opening 1300 mm; closing force 560 N; about 14 kg
Electric operator
electric cylinder (ball screw) + belt; 100 V DC; opening 1300 mm; 560 N (adjustable); 23 kg with controller
Force relaxation controller
100 V DC; 6 or 8 doors per car; under the floor or under a seat
Retractable step
1106×768×313 mm; stroke 160 mm; width 900 mm; load up to 1960 N; double-acting pneumatic cylinder; 100 V DC; 490 kPa; about 110 kg

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The door system opens and closes the doors of passenger cars of electric multiple units and metros and is responsible for safe boarding of passengers. The operator is mounted above the opening and suits double-leaf and single-leaf doors. The manufacturer offers pneumatic and electric variants, as well as accompanying devices. These are conductor switches for opening and closing, switches for cars with single-driver operation, a closing force relaxation controller and a closing controller for interaction with platform doors.

The pneumatic operator with leaf synchronization is built on a pneumatic cylinder + belt scheme. The working air pressure is 490 kPa, the solenoid valves operate from 100 or 24 V DC, and the standard opening width is 1300 mm. Manual release is by an air cock, the closing force is 560 N and the mass is about 14 kg.

The electric operator is built on an electric cylinder with a ball screw and a belt. The control voltage is 100 V DC, the opening is 1300 mm, and manual release is pneumatic or by cable. The closing force of 560 N can be adjusted, and the mass is 23 kg including the controller. In 2026 the manufacturer supplied electric door operators for the Nankai GRAN Tenku train for the first time and signed an agreement with a partner on joint development of electric door systems.

The closing force relaxation controller is powered from 100 V DC, controls 6 or 8 doors per car and is installed under the floor or under a seat. It makes it easy to remove a trapped object. The control solenoid valves of the operators work from 100 or 24 V DC.

The retractable step is located under the door opening. When activated, the platform extends toward the station platform and bridges the gap between the car and the platform. The drive is a built-in double-acting pneumatic cylinder. The step keeps a safe distance from the platform so that carbody sway does not interfere with boarding, and an interlock circuit does not let the train depart with the step extended. The dimensions in the retracted position are 1106 × 768 × 313 mm, the stroke is 160 mm, the working width is 900 mm, the permissible load is 1960 N, the voltage is 100 V DC, the pressure is 490 kPa and the mass is about 110 kg.

Technical specifications

Pneumatic operatorcylinder + belt; 490 kPa; solenoid valve 100 or 24 V DC; opening 1300 mm; closing force 560 N; about 14 kg
Electric operatorelectric cylinder (ball screw) + belt; 100 V DC; opening 1300 mm; 560 N (adjustable); 23 kg with controller
Force relaxation controller100 V DC; 6 or 8 doors per car; under the floor or under a seat
Retractable step1106×768×313 mm; stroke 160 mm; width 900 mm; load up to 1960 N; double-acting pneumatic cylinder; 100 V DC; 490 kPa; about 110 kg
Safetytrain movement interlock with the step extended; interface with platform doors

Request a price and lead time

Passenger car door operators (pneumatic and electric) and retractable steps. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What pressure and voltage does the pneumatic operator need?

Working air pressure is 490 kPa, and the solenoid valves operate from 100 or 24 V DC. The standard opening width is 1300 mm and the closing force is 560 N.

What are the mass and control voltage of the electric operator?

The control voltage is 100 V DC and the mass is 23 kg including the controller. The closing force of 560 N is adjustable, and the opening is 1300 mm.

What dimensions and load does the retractable step have?

In the retracted position 1106 × 768 × 313 mm, stroke 160 mm, working width 900 mm. The permissible load is 1960 N and the mass is about 110 kg.