ESTRA-VP20 isolated relay for voltage presence detection

The ESTRA-VP20 relay detects DC voltages in power distribution systems for public transport networks. Rated voltage is up to 3600 V, test voltage up to 10 kV AC and accuracy ±5% of the input scale.

Product type
Isolated relay for voltage presence detection (ESTRA-VP20)
Rated voltage
up to 3600 V
Test voltage
up to 10 kV AC
Application
voltage measurement up to 3600 V, directly connected to the high-voltage circuit

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ESTRA-VP detects DC voltages in power distribution systems for public transportation networks. The VP20 covers rated voltages from 750 V DC to 3000 V DC, and its high-voltage isolation protects people and property.

The relay connects directly to the high-voltage circuit and measures up to 3600 V. Detection scales are up to 1500 Vdc or 3000 Vdc, with accuracy of ±5% of the input scale. Thresholds are adjustable with internal dip switches.

Rated voltage is up to 3600 V and test voltage is up to 10 kV AC. The supply voltage is split into 3 ranges covering 24 to 230 VDC. Galvanic isolation reaches 10 kV, and immunity is high enough that no fuse is required. A diagnostic signal is provided.

Reference standards are EN 50121-5 when mounted in a cubicle, together with EN 50124-1, EN 61000-6-2 and EN 61000-6-4. The relay is intended for DC traction power supply and is designed specifically for DC railway applications.

Technical specifications

Product typeIsolated relay for voltage presence detection (ESTRA-VP20)
Rated voltageup to 3600 V
Test voltageup to 10 kV AC
Applicationvoltage measurement up to 3600 V, directly connected to the high-voltage circuit
Voltage detection scaleup to 1500 Vdc or 3000 Vdc
Accuracy±5% of input scale
Thresholdsadjustable by internal dip switches
Power supply voltage3 ranges covering 24 to 230 VDC
StandardsEN 50121-5 (in a cubicle), EN 50124-1, EN 61000-6-2, EN 61000-6-4

Part numbers

Show all part numbers (1)

VP20

How it compares with similar models

ParameterESTRA-VP20 isolated relay for voltage presence detectionESTRA-VM isolated amplifiers (VM10, VM12) for voltage measurementESTRA-MIU isolated amplifier for current measurementVGUARD voltage limiting devices for railway DC traction
Product typeIsolated relay for voltage presence detection (ESTRA-VP20)Isolated amplifier for voltage measurement (ESTRA-VM)Isolated amplifier for current measurement (ESTRA-MIU10)Voltage limiting device for railway DC traction (ESTRA-VGUARD)
Test voltageup to 10 kV ACup to 10 kV AC (15 kV for the fixed setting version)up to 10 kV AC (15 kV for the fixed setting version)—
Applicationvoltage measurement up to 3600 V, directly connected to the high-voltage circuitvoltage measurement up to 3600 V, directly connected to the high-voltage circuitcurrent measurement through a shunt resistorlimitation of dangerous touch voltages
Power supply voltage3 ranges covering 24 to 230 VDCfrom 24 to 230 VDC/VACfrom 24 to 230 VDC/VAC—
StandardsEN 50121-5 (in a cubicle), EN 50124-1, EN 61000-6-2, EN 61000-6-4EN 50121-5 (in a cubicle), EN 61326 class B, EN 61140EN 50121-5 (in a cubicle), EN 61326 class B, EN 61140EN 50122-1, EN 50526-2

Request a price and lead time

ESTRA-VP20 isolated relay for voltage presence detection. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What detection scales are available?

Up to 1500 Vdc or 3000 Vdc, with accuracy of ±5% of the input scale.

How are the thresholds set?

Thresholds are adjustable by means of internal dip switches.

What supply voltage and test voltage apply?

Supply is split into 3 ranges covering 24 to 230 VDC. Test voltage is up to 10 kV AC.