
ESTRA-MIU isolated amplifier for current measurement
The ESTRA-MIU (MIU10) amplifier measures high DC currents in power distribution systems for public transport networks, using a shunt resistor. Rated voltage is up to 3600 V and test voltage up to 10 kV AC.
- Product type
- Isolated amplifier for current measurement (ESTRA-MIU10)
- Rated voltage
- up to 3600 V
- Test voltage
- up to 10 kV AC (15 kV for the fixed setting version)
- Application
- current measurement through a shunt resistor
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The ESTRA-MIU measures high DC currents in power distribution systems for public transportation networks. The current is read through a shunt resistor. High-voltage isolation protects people and property, and protection against electric shock comes from protective separation between input, output and power supply.
The input takes bipolar voltages and is settable from 60 mV to 5 V. The output signal is settable to ±5 V, ±20 mA or 4 … 20 mA. The supply voltage runs from 24 to 230 VDC/VAC, a wide range in a compact housing.
Rated voltage is up to 3600 V. Test voltage is up to 10 kV AC, or 15 kV for the fixed setting version. Protective separation reaches 1800 V AC/DC according to EN 61140. The unit is designed to withstand permanent voltages up to 3600 V AC/DC and fast transients up to 20 kV. Galvanic isolation reaches 15 kV and immunity is high.
Reference standards are EN 50121-5 when mounted in a cubicle and EN 61326 class B (the standard for isolators). The unit is intended for DC traction power supply and is designed to work with SEPCOS.
Technical specifications
| Product type | Isolated amplifier for current measurement (ESTRA-MIU10) |
|---|---|
| Rated voltage | up to 3600 V |
| Test voltage | up to 10 kV AC (15 kV for the fixed setting version) |
| Application | current measurement through a shunt resistor |
| Input (bipolar voltages) | settable from 60 mV to 5 V |
| Output signals | ±5 V, ±20 mA or 4 … 20 mA |
| Power supply voltage | from 24 to 230 VDC/VAC |
| Protective separation | up to 1800 V AC/DC according to EN 61140 |
| Permanent voltage / fast transients | up to 3600 V AC/DC / up to 20 kV |
| Standards | EN 50121-5 (in a cubicle), EN 61326 class B, EN 61140 |
How it compares with similar models
| Parameter | ESTRA-MIU isolated amplifier for current measurement | ESTRA-VM isolated amplifiers (VM10, VM12) for voltage measurement | ESTRA-VP20 isolated relay for voltage presence detection | VGUARD voltage limiting devices for railway DC traction |
|---|---|---|---|---|
| Product type | Isolated amplifier for current measurement (ESTRA-MIU10) | Isolated amplifier for voltage measurement (ESTRA-VM) | Isolated relay for voltage presence detection (ESTRA-VP20) | Voltage limiting device for railway DC traction (ESTRA-VGUARD) |
| Test voltage | up to 10 kV AC (15 kV for the fixed setting version) | up to 10 kV AC (15 kV for the fixed setting version) | up to 10 kV AC | — |
| Application | current measurement through a shunt resistor | voltage measurement up to 3600 V, directly connected to the high-voltage circuit | voltage measurement up to 3600 V, directly connected to the high-voltage circuit | limitation of dangerous touch voltages |
| Power supply voltage | from 24 to 230 VDC/VAC | from 24 to 230 VDC/VAC | 3 ranges covering 24 to 230 VDC | — |
| Standards | EN 50121-5 (in a cubicle), EN 61326 class B, EN 61140 | EN 50121-5 (in a cubicle), EN 61326 class B, EN 61140 | EN 50121-5 (in a cubicle), EN 50124-1, EN 61000-6-2, EN 61000-6-4 | EN 50122-1, EN 50526-2 |
Request a price and lead time
ESTRA-MIU isolated amplifier for current measurement. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What input range does the amplifier have?
The bipolar voltage input is settable from 60 mV to 5 V, and the current is measured through a shunt resistor.
Which output signals are available?
The output is settable to ±5 V, ±20 mA or 4 … 20 mA.
What isolation levels apply?
Test voltage is up to 10 kV AC, or 15 kV for the fixed setting version. Protective separation is up to 1800 V AC/DC according to EN 61140.
Similar equipment from other manufacturers






