ТДЦ, ТЦ, ТНЦ, ТДЦН and ТЦН generator step-up transformers, 10–1250 MVA, HV 110–500 kV
The ТДЦ, ТЦ, ТНЦ, ТДЦН and ТЦН series are step-up transformers that work in a unit with power station generators. Ratings run from 10 to 1250 MVA at HV classes of 110, 132, 150, 220, 245, 330, 400 and 500 kV.
- Series
- ТДЦ, ТЦ, ТНЦ, ТДЦН, ТЦН
- Application
- step-up, for operation in a block with power station generators
- Rated power
- 10–1250 MVA
- HV class
- 110, 132, 150, 220, 245, 330, 400, 500 kV
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Generator (unit) transformers of the ТДЦ, ТЦ, ТНЦ, ТДЦН and ТЦН series are step-up transformers for operation in a block with power station generators. The range covers 10 to 1250 MVA and HV winding classes of 110, 132, 150, 220, 245, 330, 400 and 500 kV. A type size is written as the series followed by two numbers separated by a slash, for example ТДЦ-250000/500.
The ТДЦ series: ТДЦ-80000/110, ТДЦ-95000/150, ТДЦ-125000/110, ТДЦ-125000/220, ТДЦ-130000/150, ТДЦ-160000/110, ТДЦ-160000/220, ТДЦ-180000/110, ТДЦ-200000/110, ТДЦ-200000/220, ТДЦ-225000/110, ТДЦ-225000/220, ТДЦ-230000/110, ТДЦ-230000/220, ТДЦ-250000/110, ТДЦ-250000/220, ТДЦ-250000/500, ТДЦ-265000/330, ТДЦ-265000/500, ТДЦ-315000/220, ТДЦ-400000/500, ТДЦ-450000/220, ТДЦ-520000/220, ТДЦ-520000/500.
The ТЦ series: ТЦ-10000/150, ТЦ-27800/132, ТЦ-400000/500. The ТНЦ series: ТНЦ-630000/220, ТНЦ-1000000/330, ТНЦ-1000000/500, ТНЦ-1250000/330.
The ТДЦН series: ТДЦН-80000/110, ТДЦН-100000/220, ТДЦН-250000/500, ТДЦН-400000/245, ТДЦН-400000/500. The ТЦН series: ТЦН-780000/400.
Equipment is designed to the requirements of ГОСТ, ДСТУ, IEC, ANSI, BS and IRAM, and to the technical conditions and national standards required by the customer. The manufacturer's range includes versions for different climatic and seismic conditions. A type size is chosen from the generator unit rating and the grid voltage class.
Technical specifications
| Series | ТДЦ, ТЦ, ТНЦ, ТДЦН, ТЦН |
|---|---|
| Application | step-up, for operation in a block with power station generators |
| Rated power | 10–1250 MVA |
| HV class | 110, 132, 150, 220, 245, 330, 400, 500 kV |
| ТДЦ type sizes | ТДЦ-80000/110, ТДЦ-95000/150, ТДЦ-125000/110, ТДЦ-125000/220, ТДЦ-130000/150, ТДЦ-160000/110, ТДЦ-160000/220, ТДЦ-180000/110, ТДЦ-200000/110, ТДЦ-200000/220, ТДЦ-225000/110, ТДЦ-225000/220, ТДЦ-230000/110, ТДЦ-230000/220, ТДЦ-250000/110, ТДЦ-250000/220, ТДЦ-250000/500, ТДЦ-265000/330, ТДЦ-265000/500, ТДЦ-315000/220, ТДЦ-400000/500, ТДЦ-450000/220, ТДЦ-520000/220, ТДЦ-520000/500 |
| ТЦ type sizes | ТЦ-10000/150, ТЦ-27800/132, ТЦ-400000/500 |
| ТНЦ type sizes | ТНЦ-630000/220, ТНЦ-1000000/330, ТНЦ-1000000/500, ТНЦ-1250000/330 |
| ТДЦН type sizes | ТДЦН-80000/110, ТДЦН-100000/220, ТДЦН-250000/500, ТДЦН-400000/245, ТДЦН-400000/500 |
| ТЦН type sizes | ТЦН-780000/400 |
European equivalents
Generator step-up (unit) transformers for power stations, Core-type power transformers, including GSU generator step-up units, up to 1500 MVA, Oil-immersed power transformers up to 160 MVA, 220 kV, Generator step-up transformers up to 765 kV, OTN oil-filled power transformer up to 180 MVA, GSU generator step-up transformers for power plants up to 670 MVA, 400 kV, Power transformers and autotransformers, shell-type and core-type, Oil-immersed power transformers and power plant step-up transformers (GSU) up to 1100 MVA, up to 800 kV
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
ТДЦ, ТЦ, ТНЦ, ТДЦН and ТЦН generator step-up transformers, 10–1250 MVA, HV 110–500 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which series make up the generator transformer group?
ТДЦ, ТЦ, ТНЦ, ТДЦН and ТЦН. All are meant for operation in a unit with power station generators.
What power and voltage class range is covered?
Rated power runs from 10 to 1250 MVA. HV classes are 110, 132, 150, 220, 245, 330, 400 and 500 kV.
Which type sizes exist in the ТНЦ series?
ТНЦ-630000/220, ТНЦ-1000000/330, ТНЦ-1000000/500 and ТНЦ-1250000/330.
CIS originals replaced by this item
Similar equipment from other manufacturers