ТДТН, ТРДЦТН and ТРДТНС three-winding power transformers, 25–80 MVA, HV class 110–220 kV

Three-winding power transformers of series ТДТН, ТРДЦТН and ТРДТНС for substations with three voltage classes. Rated power is 25–80 MVA and the HV class is 110, 150 or 220 kV.

Series
ТДТН, ТРДЦТН, ТРДТНС
Rated power
25–80 MVA
HV voltage class
110, 150, 220 kV
Type designations ТДТН
ТДТН-25000/150

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series ТДТН, ТРДЦТН and ТРДТНС are three-winding power transformers for substations that operate at three voltage classes. With three windings, networks of three different classes can be connected to a single transformer.

Rated power across the group is 25–80 MVA. The HV class is 110, 150 or 220 kV. The three series are told apart by their designations, and each has its own type designations.

Series ТДТН: ТДТН-25000/150. Series ТРДЦТН: ТРДЦТН-80000/110.

Series ТРДТНС: ТРДТНС-63000/220.

The list for the group has three type designations: ТДТН-25000/150, ТРДЦТН-80000/110 and ТРДТНС-63000/220. They span 25 to 80 MVA, and the 150, 110 and 220 kV classes are spread across the three series.

A type designation holds the series, a number and a second number after the slash, for example ТДТН-25000/150. The designations above illustrate the group; the specification table gives its parameters.

To select a transformer, state the series, the rated power and the HV class. These three items define the type designation; if the version needed is not among the examples, it is confirmed from the series and the power.

Technical specifications

SeriesТДТН, ТРДЦТН, ТРДТНС
Rated power25–80 MVA
HV voltage class110, 150, 220 kV
Type designations ТДТНТДТН-25000/150
Type designations ТРДЦТНТРДЦТН-80000/110
Type designations ТРДТНСТРДТНС-63000/220

How it compares with similar models

ParameterТДТН, ТРДЦТН and ТРДТНС three-winding power transformers, 25–80 MVA, HV class 110–220 kVТМН, ТМ, ТМШ and ТМПУ medium-power oil-filled transformers, 1–62.5 MVA, HV class 10–220 kVТДЦ, ТЦ, ТНЦ, ТДЦН and ТЦН generator step-up transformers, 10–1250 MVA, HV 110–500 kVТДН, ТРДН, ТРДНС, ТРДЦН, ТД and ТРД two-winding power transformers with OLTC, 16–630 MVA
Rated power25–80 MVA1–62.5 MVA10–1250 MVA16–630 MVA
HV voltage class110, 150, 220 kV10, 20, 35, 132, 220 kV—10, 15, 16, 17, 23, 24, 33, 34, 35, 66, 110, 121, 145, 150, 154, 220, 230, 330, 347, 400, 500, 525 kV

European equivalents

CompactStar™ compact power transformer for offshore and urban substations, SZ / SSZ / SFSZ 35–220 kV OLTC power transformers for substations, Medium power transformers up to 160 MVA, 170 kV, Grid power transformers with separate windings up to 500 MVA, Medium-power transformers 5–100 MVA, up to 245 kV

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

ТДТН, ТРДЦТН and ТРДТНС three-winding power transformers, 25–80 MVA, HV class 110–220 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What rated power do these three-winding transformers cover?

Rated power is 25–80 MVA, from ТДТН-25000/150 up to ТРДЦТН-80000/110.

Which HV classes are offered?

The HV class is 110, 150 or 220 kV. Examples are ТРДЦТН-80000/110, ТДТН-25000/150 and ТРДТНС-63000/220.

What substations are these transformers meant for?

Substations with three voltage classes. The three windings allow networks of three different classes to be connected to one transformer.

CIS originals replaced by this item

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides