International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Medium-power transformers 5–100 MVA, up to 245 kV

Oil-filled medium-power transformers rated 5–100 MVA for voltages up to 245 kV. They are installed at substations, industrial sites and power plants. Voltage is regulated under load or off-circuit.

Rating
5–100 MVA
Voltage
up to 245 kV
OLTC
range up to 22 %, up to 27 steps
Off-circuit tap changer
for example ±5 %

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The OLTC gives a regulation range of up to 22 % and up to 27 steps. For the off-circuit tap changer a typical range is, for example, ±5 %. Vector groups are YNd5, YNd11, YNyn0 and YNyn6, with and without a compensation winding. The transformers comply with IEC 60076, VDE 0532 and IEC 60354. Production is in Germany, Malaysia and the USA.

Technical specifications

Rating5–100 MVA
Voltageup to 245 kV
OLTCrange up to 22 %, up to 27 steps
Off-circuit tap changerfor example ±5 %
Vector groupsYNd5, YNd11, YNyn0, YNyn6 (with and without compensation winding)
StandardsIEC 60076, VDE 0532, IEC 60354
ProductionGermany, Malaysia, USA

Replacement for

ТМН-6300/35, ТДН-16000/110, ТРДН-40000/110, ТДТН-63000/110, ТРДЦН-63000/220, ТРДЦН-100000/220

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Medium-power transformers 5–100 MVA, up to 245 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 22 90 00
8504 23 00 00
HS, 6 digits8504 23
CN (EU)8504 22 90
8504 23 00
HTSUS (USA)8504 22 00 80
8504 23 00 41
8504 23 00 45
China customs tariff8504 22 00 00
8504 23 11 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltage class are the transformers designed for?

For voltages up to 245 kV at ratings of 5–100 MVA.

What regulation range does the OLTC provide?

Up to 22 % with up to 27 steps. Off-circuit regulation is done with the tap changer, for example ±5 %.

Which winding vector groups are available?

YNd5, YNd11, YNyn0 and YNyn6, with or without a compensation winding.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides