АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ autotransformers, 63–667 MVA, HV class 220–1150 kV
Three-phase and single-phase autotransformers of series АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ for linking 220–1150 kV networks. Rated power is 63–667 MVA; the HV class is 220, 330, 400, 500, 750 or 1150 kV.
- Series
- АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ, АОДТН, АОРДЦТН, ОДЦТ, ОДЦТНП, ОДЦТП
- Rated power
- 63–667 MVA
- HV voltage class
- 220, 330, 400, 500, 750, 1150 kV
- Type designations АТДЦТН
- АТДЦТН-63000/220, АТДЦТН-125000/220, АТДЦТН-125000/330, АТДЦТН-200000/220, АТДЦТН-200000/330, АТДЦТН-240000/330, АТДЦТН-250000/220, АТДЦТН-250000/330, АТДЦТН-250000/500, АТДЦТН-315000/400, АТДЦТН-400000/400, АТДЦТН-500000/500
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The autotransformers in this group link networks of 220–1150 kV. The range has three-phase and single-phase versions in series АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ.
The complete series list is АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ, АОДТН, АОРДЦТН, ОДЦТ, ОДЦТНП and ОДЦТП. Rated power is 63–667 MVA. The HV class is 220, 330, 400, 500, 750 or 1150 kV.
Series АТДЦТН: АТДЦТН-63000/220, АТДЦТН-250000/220 and АТДЦТН-500000/500. Series АТДТН: АТДТН-63000/220, АТДТН-125000/330 and АТДТН-200000/330. Series АТДЦН: АТДЦН-500000/500. Series АОДЦТН: АОДЦТН-135000/500, АОДЦТН-200000/400 and АОДЦТН-417000/750. Series АОДЦТ: АОДЦТ-667000/1150.
Series АОДТН: АОДТН-167000/500. Series АОРДЦТН: АОРДЦТН-250000/500. Series ОДЦТ: ОДЦТ-417000/750. Series ОДЦТНП: ОДЦТНП-135000/400. Series ОДЦТП: ОДЦТП-135000/400.
A type designation is a series name followed by two numbers joined by a hyphen and a slash, for example АТДЦТН-250000/500 or АОДЦТН-333000/750. The largest entry in the list, АОДЦТ-667000/1150, is in the 1150 kV class.
Selection starts from the HV class and the rated power, which together fix the series and the type designation. The specification table gives the whole list of type designations.
Technical specifications
| Series | АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ, АОДТН, АОРДЦТН, ОДЦТ, ОДЦТНП, ОДЦТП |
|---|---|
| Rated power | 63–667 MVA |
| HV voltage class | 220, 330, 400, 500, 750, 1150 kV |
| Type designations АТДЦТН | АТДЦТН-63000/220, АТДЦТН-125000/220, АТДЦТН-125000/330, АТДЦТН-200000/220, АТДЦТН-200000/330, АТДЦТН-240000/330, АТДЦТН-250000/220, АТДЦТН-250000/330, АТДЦТН-250000/500, АТДЦТН-315000/400, АТДЦТН-400000/400, АТДЦТН-500000/500 |
| Type designations АТДТН | АТДТН-63000/220, АТДТН-125000/220, АТДТН-125000/330, АТДТН-150000/330, АТДТН-200000/330 |
| Type designations АТДЦН | АТДЦН-500000/500 |
| Type designations АОДЦТН | АОДЦТН-135000/500, АОДЦТН-150000/500, АОДЦТН-167000/500, АОДЦТН-200000/400, АОДЦТН-333000/750, АОДЦТН-417000/750 |
| Type designations АОДЦТ | АОДЦТ-667000/1150 |
| Type designations АОДТН | АОДТН-167000/500 |
| Type designations АОРДЦТН | АОРДЦТН-250000/500 |
| Type designations ОДЦТ | ОДЦТ-417000/750 |
| Type designations ОДЦТНП | ОДЦТНП-135000/400 |
| Type designations ОДЦТП | ОДЦТП-135000/400 |
How it compares with similar models
| Parameter | АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ autotransformers, 63–667 MVA, HV class 220–1150 kV | ТДТН, ТРДЦТН and ТРДТНС three-winding power transformers, 25–80 MVA, HV class 110–220 kV | ТМН, ТМ, ТМШ and ТМПУ medium-power oil-filled transformers, 1–62.5 MVA, HV class 10–220 kV | ТДЦ, ТЦ, ТНЦ, ТДЦН and ТЦН generator step-up transformers, 10–1250 MVA, HV 110–500 kV |
|---|---|---|---|---|
| Rated power | 63–667 MVA | 25–80 MVA | 1–62.5 MVA | 10–1250 MVA |
| HV voltage class | 220, 330, 400, 500, 750, 1150 kV | 110, 150, 220 kV | 10, 20, 35, 132, 220 kV | — |
European equivalents
Large power transformers up to 525 kV, 750 MVA, Autotransformers up to 1000 MVA, Substation autotransformers and interconnecting transformers up to 1300 MVA, ODFS / ODFPSZ / OSFSZ 330–750 kV, Autotransformers for system-forming networks 400–500 kV, Medium and large power transformers up to 1100 kV / 1300 MVA, Single-phase power transformers and autotransformers 16.7/50/60 Hz, High-power autotransformers up to 1500 MVA, up to 800 kV
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ autotransformers, 63–667 MVA, HV class 220–1150 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What rated power do the autotransformers cover?
Rated power is 63–667 MVA, from АТДЦТН-63000/220 up to АОДЦТ-667000/1150.
Which HV classes are available?
The HV classes are 220, 330, 400, 500, 750 and 1150 kV. АОДЦТ-667000/1150 is in the 1150 kV class and АТДЦТН-63000/220 in the 220 kV class.
Which autotransformers are listed for 750 kV?
Three type designations are listed for 750 kV: АОДЦТН-333000/750, АОДЦТН-417000/750 and ОДЦТ-417000/750.
CIS originals replaced by this item
Similar equipment from other manufacturers