International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ autotransformers, 63–667 MVA, HV class 220–1150 kV

Three-phase and single-phase autotransformers of series АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ for linking 220–1150 kV networks. Rated power is 63–667 MVA; the HV class is 220, 330, 400, 500, 750 or 1150 kV.

Series
АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ, АОДТН, АОРДЦТН, ОДЦТ, ОДЦТНП, ОДЦТП
Rated power
63–667 MVA
HV voltage class
220, 330, 400, 500, 750, 1150 kV
Type designations АТДЦТН
АТДЦТН-63000/220, АТДЦТН-125000/220, АТДЦТН-125000/330, АТДЦТН-200000/220, АТДЦТН-200000/330, АТДЦТН-240000/330, АТДЦТН-250000/220, АТДЦТН-250000/330, АТДЦТН-250000/500, АТДЦТН-315000/400, АТДЦТН-400000/400, АТДЦТН-500000/500

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The autotransformers in this group link networks of 220–1150 kV. The range has three-phase and single-phase versions in series АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ.

The complete series list is АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ, АОДТН, АОРДЦТН, ОДЦТ, ОДЦТНП and ОДЦТП. Rated power is 63–667 MVA. The HV class is 220, 330, 400, 500, 750 or 1150 kV.

Series АТДЦТН: АТДЦТН-63000/220, АТДЦТН-250000/220 and АТДЦТН-500000/500. Series АТДТН: АТДТН-63000/220, АТДТН-125000/330 and АТДТН-200000/330. Series АТДЦН: АТДЦН-500000/500. Series АОДЦТН: АОДЦТН-135000/500, АОДЦТН-200000/400 and АОДЦТН-417000/750. Series АОДЦТ: АОДЦТ-667000/1150.

Series АОДТН: АОДТН-167000/500. Series АОРДЦТН: АОРДЦТН-250000/500. Series ОДЦТ: ОДЦТ-417000/750. Series ОДЦТНП: ОДЦТНП-135000/400. Series ОДЦТП: ОДЦТП-135000/400.

A type designation is a series name followed by two numbers joined by a hyphen and a slash, for example АТДЦТН-250000/500 or АОДЦТН-333000/750. The largest entry in the list, АОДЦТ-667000/1150, is in the 1150 kV class.

Selection starts from the HV class and the rated power, which together fix the series and the type designation. The specification table gives the whole list of type designations.

Technical specifications

SeriesАТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ, АОДТН, АОРДЦТН, ОДЦТ, ОДЦТНП, ОДЦТП
Rated power63–667 MVA
HV voltage class220, 330, 400, 500, 750, 1150 kV
Type designations АТДЦТНАТДЦТН-63000/220, АТДЦТН-125000/220, АТДЦТН-125000/330, АТДЦТН-200000/220, АТДЦТН-200000/330, АТДЦТН-240000/330, АТДЦТН-250000/220, АТДЦТН-250000/330, АТДЦТН-250000/500, АТДЦТН-315000/400, АТДЦТН-400000/400, АТДЦТН-500000/500
Type designations АТДТНАТДТН-63000/220, АТДТН-125000/220, АТДТН-125000/330, АТДТН-150000/330, АТДТН-200000/330
Type designations АТДЦНАТДЦН-500000/500
Type designations АОДЦТНАОДЦТН-135000/500, АОДЦТН-150000/500, АОДЦТН-167000/500, АОДЦТН-200000/400, АОДЦТН-333000/750, АОДЦТН-417000/750
Type designations АОДЦТАОДЦТ-667000/1150
Type designations АОДТНАОДТН-167000/500
Type designations АОРДЦТНАОРДЦТН-250000/500
Type designations ОДЦТОДЦТ-417000/750
Type designations ОДЦТНПОДЦТНП-135000/400
Type designations ОДЦТПОДЦТП-135000/400

How it compares with similar models

ParameterАТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ autotransformers, 63–667 MVA, HV class 220–1150 kVТДТН, ТРДЦТН and ТРДТНС three-winding power transformers, 25–80 MVA, HV class 110–220 kVТМН, ТМ, ТМШ and ТМПУ medium-power oil-filled transformers, 1–62.5 MVA, HV class 10–220 kVТДЦ, ТЦ, ТНЦ, ТДЦН and ТЦН generator step-up transformers, 10–1250 MVA, HV 110–500 kV
Rated power63–667 MVA25–80 MVA1–62.5 MVA10–1250 MVA
HV voltage class220, 330, 400, 500, 750, 1150 kV110, 150, 220 kV10, 20, 35, 132, 220 kV—

European equivalents

Large power transformers up to 525 kV, 750 MVA, Autotransformers up to 1000 MVA, Substation autotransformers and interconnecting transformers up to 1300 MVA, ODFS / ODFPSZ / OSFSZ 330–750 kV, Autotransformers for system-forming networks 400–500 kV, Medium and large power transformers up to 1100 kV / 1300 MVA, Single-phase power transformers and autotransformers 16.7/50/60 Hz, High-power autotransformers up to 1500 MVA, up to 800 kV

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

АТДЦТН, АТДТН, АТДЦН, АОДЦТН, АОДЦТ and ОДЦТ autotransformers, 63–667 MVA, HV class 220–1150 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What rated power do the autotransformers cover?

Rated power is 63–667 MVA, from АТДЦТН-63000/220 up to АОДЦТ-667000/1150.

Which HV classes are available?

The HV classes are 220, 330, 400, 500, 750 and 1150 kV. АОДЦТ-667000/1150 is in the 1150 kV class and АТДЦТН-63000/220 in the 220 kV class.

Which autotransformers are listed for 750 kV?

Three type designations are listed for 750 kV: АОДЦТН-333000/750, АОДЦТН-417000/750 and ОДЦТ-417000/750.

CIS originals replaced by this item

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides