International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Autotransformers for system-forming networks 400–500 kV

Large interconnection autotransformers for extra-high-voltage intersystem substations. They link 400–500 kV networks with 230–275 kV or 120–145 kV networks. Implemented units include an 840 MVA 345/230 kV autotransformer.

Application
linking 400–500 kV networks with 230–275 kV or 120–145 kV
Example design
840 MVA 345/230 kV
Tertiary winding
delta, to order
Production
Nijmegen, Netherlands

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The autotransformer is installed at the boundary of power systems, where a 400–500 kV network connects to a network of a lower class, 230–275 kV or 120–145 kV. The implemented example is rated for 345/230 kV at 840 MVA. A delta-connected tertiary winding is provided to order. Production is in Nijmegen, Netherlands.

Technical specifications

Applicationlinking 400–500 kV networks with 230–275 kV or 120–145 kV
Example design840 MVA 345/230 kV
Tertiary windingdelta, to order
ProductionNijmegen, Netherlands

Replacement for

АТДЦТН-200000/330/110, АОДЦТН-167000/500/220, АОДЦТН-267000/500/220

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Autotransformers for system-forming networks 400–500 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 21 00 00
8504 22 10 00
8504 22 90 00
8504 23 00 00
HS, 6 digits8504 23
CN (EU)8504 21 00
8504 22 10
8504 22 90
8504 23 00
HTSUS (USA)8504 21 00 20
8504 21 00 40
8504 21 00 60
8504 21 00 80
8504 22 00 40
8504 22 00 80
8504 23 00 41
8504 23 00 45
8504 23 00 80
China customs tariff8504 21 00 00
8504 22 00 00
8504 23 11 00
8504 23 12 00
8504 23 13 00
8504 23 21 00
8504 23 29 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which networks do these autotransformers link?

Networks of 400–500 kV with networks of 230–275 kV or 120–145 kV.

What is the rating of the implemented autotransformer?

The example design is rated 840 MVA at 345/230 kV.

Is there a tertiary winding?

A delta-connected tertiary winding is supplied to order.