АОДЦТН-267000/500/220 (AODTsTN-267000/500/220) — single-phase three-winding autotransformer with forced oil-air cooling (DTs) and on-load tap changer
Voltage transformation in power grids and substations: supplying consumers, linking networks of different voltage classes and exporting power-plant output.
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Voltage transformation in power grids and substations: supplying consumers, linking networks of different voltage classes and exporting power-plant output.
Technical specifications
| Type | Single-phase three-winding autotransformer with forced oil-air cooling (DTs) and on-load tap changer |
|---|---|
| Designation | АОДЦТН-267000/500/220 |
| Parameter | rated power (per designation) 267000 kVA |
| HV winding voltage class 500 kV | |
| MV winding voltage class 220 kV |
Request a price and lead time
АОДЦТН-267000/500/220. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
European analogues of АОДЦТН-267000/500/220

Power transformers and autotransformersOil-immersed autotransformers for interconnecting HV and EHV networks, up to 1000 MVA

Power transformers and autotransformersAutotransformers up to 1300 MVA, primary voltage up to 765 kV, with OLTC

Power transformers and autotransformersGrid-coupling autotransformers and transformers 330–750 kV, 180–1000 MVA

Power transformers and autotransformersInterconnection autotransformers for 400–500 kV networks, 840 MVA 345/230 kV design

Special transformersAutotransformers for grid interconnection, up to 1000/1500 MVA, up to 800 kV

Special transformersGrid transformers and autotransformers 380–400 kV, example 250 MVA, 400/135 kV
Analogue selection is for reference only, by purpose and connection dimensions. Before replacement, check the specifications and wiring diagram against the product passport.
Designations of the АОДЦТН series
| АОДЦТН-167000/500/220 | rated power (per designation) 167000 kVA; HV winding voltage class 500 kV; MV winding voltage class 220 kV |
|---|---|
| АОДЦТН-267000/500/220 | rated power (per designation) 267000 kVA; HV winding voltage class 500 kV; MV winding voltage class 220 kV |
| АОДЦТН-333000/750/330 | rated power (per designation) 333000 kVA; HV winding voltage class 750 kV; MV winding voltage class 330 kV |
| АОДЦТН-417000/750/500 | rated power (per designation) 417000 kVA; HV winding voltage class 750 kV; MV winding voltage class 500 kV |
| АОДЦТН-667000/1150/500 | rated power (per designation) 667000 kVA; HV winding voltage class 1150 kV; MV winding voltage class 500 kV |