International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Medium power transformers up to 160 MVA, 170 kV

Three-phase oil-immersed medium power transformers up to 160 MVA for voltages up to 170 kV. Installed at grid company substations, at power plants and in industry. The manufacturer handles orders through the full cycle, from design to commissioning.

Rating
up to 160 MVA
Um
up to 170 kV
Design
two-winding and three-winding, with voltage switching, with a stabilising winding, generator
Regulation
OLTC, DETC or switching under the tank cover

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Two-winding and three-winding transformers are produced, as well as versions with voltage switching, with a stabilising winding, and generator transformers. Regulation is possible on load (OLTC), off-circuit (DETC) or by switching under the tank cover. The insulating liquid is at the customer's choice: mineral oil, natural or synthetic esters. Design and testing are to IEC 60076. According to the manufacturer, more than 4000 units with a total capacity of 85,000 MVA have been delivered to more than 110 countries over 40 years.

Technical specifications

Ratingup to 160 MVA
Umup to 170 kV
Designtwo-winding and three-winding, with voltage switching, with a stabilising winding, generator
RegulationOLTC, DETC or switching under the tank cover
Insulating liquidmineral oil, natural or synthetic esters
StandardIEC 60076
Experiencemore than 4000 units, 85,000 MVA in 110+ countries over 40 years

Replacement for

ТМН-6300/35, ТДН-16000/110, ТРДН-40000/110, ТДТН-40000/110, ТРДЦН-63000/110, ТРДЦН-100000/220

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Medium power transformers up to 160 MVA, 170 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 21 00 00
8504 22 10 00
8504 22 90 00
8504 23 00 00
HS, 6 digits8504 23
CN (EU)8504 21 00
8504 22 10
8504 22 90
8504 23 00
HTSUS (USA)8504 21 00 20
8504 21 00 40
8504 21 00 60
8504 21 00 80
8504 22 00 40
8504 22 00 80
8504 23 00 80
China customs tariff8504 21 00 00
8504 22 00 00
8504 23 11 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What is the upper limit of rating and voltage for these power transformers?

The medium power series is produced up to 160 MVA with a highest operating voltage up to 170 kV.

Can a transformer with an ester liquid instead of mineral oil be ordered?

Yes, besides mineral oil, natural and synthetic esters are used.

What voltage regulation options are available?

OLTC on load, off-circuit DETC or switching under the tank cover. Two-winding and three-winding versions are available, as well as generator ones and ones with a stabilising winding.