TDOK RO Oil-Immersed Compensation Reactor with On-Load Tap Changer, 546 kVAr – 15 MVAr

The TDOK RO is an oil-immersed reactive power compensation reactor fitted with an on-load tap changer. It is rated 546 kVAr – 15 MVAr at up to 36 kV, with ONAN or KNAN cooling and Y or YN connection.

Rated power
546 kVAr – 15 MVAr
Rated voltage
up to 36 kV
Cooling
ONAN or KNAN (does not apply to the oil in the on-load tap changer)
Insulation class
according to N-EN 60085

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

On wind farms, in urbanised and industrial distribution networks and on railway networks, long cable lines produce capacitive current. The TDOK RO reactor compensates it and is connected in parallel with the MV network. An on-load tap changer adjusts its operating parameters to the compensating current. The characteristic is linear at any supply voltage.

Rated power is from 546 kVAr to 15 MVAr and rated voltage is up to 36 kV. Cooling is ONAN or KNAN, which does not apply to the oil in the on-load tap changer. Connection is Y or YN and the insulation class follows N-EN 60085.

The core is cold-rolled transformer steel with inorganic insulation. The windings are round or profiled copper wire with class H insulation. The radiator tank is powder-painted sheet steel with a C4 or C5 anticorrosion system and stands on a wheeled chassis whose wheels can be reset to the direction of travel. The finish is RAL 7033, and another colour can be supplied. At higher powers the reactor can be built with an oil cooler.

Standard fittings are porcelain HV bushings to DIN 42531 or EN 50180:2010 (or connector bushings), oil level indicator, Buchholz relay, drain valve to EN 50216-4 or DIN 42551, earthing terminals on the chassis, rating plate, dehydrating breather, contact thermometer, conservator with oil drain and filler, filler on the cover, lifting lugs, pressure relief valve and a protection box. The on-load tap changer can be made with 8 to 18 positions.

Options are a 7-position off-circuit tap changer (other adjustment on request), surge arresters and anti-vibration pads. Manufacture, testing and tolerances follow PN EN 60076-1 and PN EN 60076-6. Units with other parameters are built by individual agreement.

Technical specifications

Rated power546 kVAr – 15 MVAr
Rated voltageup to 36 kV
CoolingONAN or KNAN (does not apply to the oil in the on-load tap changer)
Insulation classaccording to N-EN 60085
Connection schemeY or YN
Tap changeron-load, 8 to 18 positions
Corecold-rolled transformer steel with inorganic insulation
Windingsround or profiled wire with class H insulation, copper
Tankradiator tank, powder-painted sheet steel, C4 or C5 anticorrosion system
Finish colourRAL 7033

How it compares with similar models

ParameterTDOK RO Oil-Immersed Compensation Reactor with On-Load Tap Changer, 546 kVAr – 15 MVArTDOK C Oil-Filled Shunt Compensation Reactor with Cooler, 10–25 MVAr, up to 36 kVTDOK Oil-Immersed Compensation Reactor, 40 kVAr to 10 MVAr, up to 36 kVTDOK Oil-Immersed Compensation Reactor, 150 kVAr to 13 MVAr, up to 36 kV
Rated power546 kVAr – 15 MVAr10 MVAr – 25 MVAr40 kVAr to 10 MVAr150 kVAr to 13 MVAr (with on-load tap changer)
CoolingONAN or KNAN (does not apply to the oil in the on-load tap changer)OFAF or KFAFONAN, KNANONAN, KNAN
Windingsround or profiled wire with class H insulation, copperround or profiled wire with class H insulation, copper or aluminiumcoppercopper
Tankradiator tank, powder-painted sheet steel, C4 or C5 anticorrosion systemwith oil cooler, powder-painted sheet steel, C4 or C5 anticorrosion systemhermetic (no conservator) or with conservator, powder-painted or hot-dip galvanisedhermetic (no conservator) or with conservator, powder-painted or hot-dip galvanised

Request a price and lead time

TDOK RO Oil-Immersed Compensation Reactor with On-Load Tap Changer, 546 kVAr – 15 MVAr. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the TDOK RO differ in regulation?

It has an on-load tap changer, which can be made with 8 to 18 positions. A 7-position off-circuit tap changer can be added as an option.

What are its power and voltage ratings?

Rated power is 546 kVAr – 15 MVAr and rated voltage is up to 36 kV. Cooling is ONAN or KNAN and connection is Y or YN.

Can it be built with an oil cooler?

Yes, at higher powers the reactor can have an oil cooler. The basic tank is a radiator tank.