TDOK C Oil-Filled Shunt Compensation Reactor with Cooler, 10–25 MVAr, up to 36 kV
The TDOK C is an oil-filled reactor with an oil cooler that offsets capacitive currents on medium voltage networks. It is rated 10 MVAr – 25 MVAr at up to 36 kV, with OFAF or KFAF cooling and Y or YN connection.
- Rated power
- 10 MVAr – 25 MVAr
- Rated voltage
- up to 36 kV
- Cooling
- OFAF or KFAF
- Insulation class
- according to N-EN 60085
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Long cable lines on wind farms, in urbanised and industrial distribution networks and on railway networks generate capacitive current. The TDOK C reactor compensates it and is connected in parallel with the MV network. Its characteristic stays fully linear whatever the supply voltage.
Rated power is 10 MVAr – 25 MVAr and rated voltage is up to 36 kV, at 50 or 60 Hz. Connection is Y or YN, cooling is OFAF or KFAF, and the insulation class follows N-EN 60085. Maximum operating altitude is 1000 m above sea level, and ambient temperature ranges from -25 to 40 °C.
The core is cold-rolled transformer steel with inorganic insulation. Windings are round or profiled wire with class H insulation, in copper or aluminium. The tank carries an oil cooler and is made of powder-painted sheet steel with a C4 or C5 anticorrosion system, finished in RAL 7033. It stands on a wheeled chassis whose wheels can be reset for longitudinal or transverse travel. The cooler and its pump are selected according to the unit's power.
Standard fittings are porcelain HV bushings to DIN 42531 or EN 50180:2010 (or connector bushings), oil level indicator, Buchholz relay, drain valve to EN 50216-4 or DIN 42551, earthing terminals on the chassis, rating plate, dehydrating breather, contact thermometer, conservator with drain and filler, filler on the cover, lifting lugs, off-circuit tap changer, pressure relief valve and a protection box.
Options include a 7-position tap changer for current adjustment (other adjustment on request), surge arresters and anti-vibration pads. An additional auxiliary supply winding can be made once technical feasibility has been confirmed with the manufacturer. Manufacture, testing and tolerances follow PN EN 60076-1 and PN EN 60076-6. Units with other parameters are built by individual agreement.
Technical specifications
| Rated power | 10 MVAr – 25 MVAr |
|---|---|
| Rated voltage | up to 36 kV |
| Cooling | OFAF or KFAF |
| Insulation class | according to N-EN 60085 |
| Connection scheme | Y or YN |
| Rated frequency | 50 or 60 Hz |
| Max. operating altitude | 1000 m above sea level |
| Ambient temperature range | -25 to 40 °C |
| Core | cold-rolled transformer steel with inorganic insulation |
| Windings | round or profiled wire with class H insulation, copper or aluminium |
| Tank | with oil cooler, powder-painted sheet steel, C4 or C5 anticorrosion system |
| Finish colour | RAL 7033 |
How it compares with similar models
| Parameter | TDOK C Oil-Filled Shunt Compensation Reactor with Cooler, 10–25 MVAr, up to 36 kV | TDOK Oil-Immersed Compensation Reactor, 40 kVAr to 10 MVAr, up to 36 kV | TDOK Oil-Immersed Compensation Reactor, 150 kVAr to 13 MVAr, up to 36 kV | TDOK RO Oil-Immersed Compensation Reactor with On-Load Tap Changer, 546 kVAr – 15 MVAr |
|---|---|---|---|---|
| Rated power | 10 MVAr – 25 MVAr | 40 kVAr to 10 MVAr | 150 kVAr to 13 MVAr (with on-load tap changer) | 546 kVAr – 15 MVAr |
| Cooling | OFAF or KFAF | ONAN, KNAN | ONAN, KNAN | ONAN or KNAN (does not apply to the oil in the on-load tap changer) |
| Windings | round or profiled wire with class H insulation, copper or aluminium | copper | copper | round or profiled wire with class H insulation, copper |
| Tank | with oil cooler, powder-painted sheet steel, C4 or C5 anticorrosion system | hermetic (no conservator) or with conservator, powder-painted or hot-dip galvanised | hermetic (no conservator) or with conservator, powder-painted or hot-dip galvanised | radiator tank, powder-painted sheet steel, C4 or C5 anticorrosion system |
Request a price and lead time
TDOK C Oil-Filled Shunt Compensation Reactor with Cooler, 10–25 MVAr, up to 36 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which networks is the TDOK C reactor intended for?
It compensates capacitive currents in long cable lines, including those on wind farms, in urbanised and industrial distribution networks and on railway networks. It is connected in parallel with the MV network.
Can the compensating current be adjusted?
Yes. A 7-position tap changer for current adjustment is available as an option, and other adjustment can be made on request. The standard set includes an off-circuit tap changer.
What cooling and winding materials are used?
Cooling is OFAF or KFAF, with an oil cooler and pump on the tank. Windings are copper or aluminium, in round or profiled wire with class H insulation.
Similar equipment from other manufacturers