Three-phase dry-type earthing transformers create an artificial neutral point in resistor-earthed and compensated networks. Rated power is 150 kVA to 4 MVA, voltage up to 36 kV, compensation current 15 A to 300 A, connection group ZNyn11.
- Rated power
- 150 kVA to 4 MVA
- Rated voltage
- up to 36 kV
- Compensation current
- 15 A to 300 A
- Connection group
- ZNyn11
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
A dry-type earthing transformer provides an artificial neutral point in networks earthed through a resistor or in compensated networks. These are three-phase transformers which, while there is no earth fault, also supply the station auxiliaries, with auxiliary power up to 315 kVA.
The characteristic connection group of an earthing transformer is ZNyn11. In a fault (earth fault) it spreads the fault current across all phases, reducing its value in the faulty line. The secondary winding can run continuously at rated conditions even when the primary winding carries a compensation current.
In resistor-earthed networks the neutral point is connected to an earthed resistor that forces the active component. In compensated networks it is normally connected to an arc suppression reactor, which adds the reactance needed to extinguish the arc and compensate earth fault currents. The construction of resin earthing transformers also suits difficult operating conditions and places that call for higher safety standards.
The production range is 150 kVA to 4 MVA at rated voltage up to 36 kV, with compensation current from 15 A to 300 A, AN cooling and insulation class F or H. Rated frequency is 50 or 60 Hz, although the operating conditions list 50 Hz only. Maximum operating altitude is 1000 m above sea level and ambient temperature is from -25 to 40 °C.
The core is cold-rolled electrical steel with inorganic insulation. Windings are copper or aluminium, made by vacuum technology or by roving with glass fibre. The standard enclosure is IP00; a metal enclosure with a specified IP degree, such as IP20, IP21, IP23, IP31, IP33 or IP54, is made on request. Temperature sensing uses PT100 or PTC probes together with protection.
Optional items are anti-vibration pads, surge arresters, an enclosure, fans and connector bushings. Design, tests and tolerances follow PN EN 60076-1, PN EN 60076-11 and PN EN 60076-6, and units with other parameters are made by individual agreement.
Technical specifications
| Rated power | 150 kVA to 4 MVA |
|---|---|
| Rated voltage | up to 36 kV |
| Compensation current | 15 A to 300 A |
| Connection group | ZNyn11 |
| Cooling | AN |
| Insulation class | F or H |
| Rated frequency | 50 or 60 Hz |
| Max. operating altitude | 1000 m above sea level |
| Ambient temperature range | -25 to 40 °C |
| Core | cold-rolled electrical steel with inorganic insulation |
| Windings | copper or aluminium, vacuum technology or roving with glass fibre |
| Enclosure | standard IP00; metal enclosure with specified IP degree (IP20, IP21, IP23, IP31, IP33, IP54 etc.) on request |
| Standards | PN EN 60076-1, PN EN 60076-11, PN EN 60076-6 |
How it compares with similar models
| Parameter | Dry-type earthing transformers 150 kVA to 4 MVA, up to 36 kV, ZNyn11 | Oil-filled earthing transformers 150 kVA to 4 MVA, up to 36 kV, ZNyn11 | Dry arc suppression reactors (Petersen coils) 150 kVAr to 4 MVAr, up to 36 kV | BTUZ resin earthing transformer, 150 kVA to 4 MVA, up to 36 kV |
|---|---|---|---|---|
| Rated power | 150 kVA to 4 MVA | 150 kVA to 4 MVA | 150 kVAr to 4 MVAr | 150 kVA to 4 MVA |
| Rated voltage | up to 36 kV | up to 36 kV | up to 36 kV | Up to 36 kV |
| Rated frequency | 50 or 60 Hz | 50 Hz | 50 Hz | 50 or 60 Hz |
| Windings | copper or aluminium, vacuum technology or roving with glass fibre | round or profiled wire with class H varnish insulation, copper or aluminium | copper or aluminium, vacuum technology or roving with glass fibre | Copper or aluminium, vacuum or roving technique with glass fibre |
| Enclosure | standard IP00; metal enclosure with specified IP degree (IP20, IP21, IP23, IP31, IP33, IP54 etc.) on request | — | standard IP00; metal enclosure with specified IP degree (IP20, IP21, IP23, IP31, IP33, IP54 etc.) on request | IP 00 as standard, optional metal enclosure (IP20, IP21, IP23, IP31, IP33, IP54 etc.) |
| Standards | PN EN 60076-1, PN EN 60076-11, PN EN 60076-6 | PN EN 60076-1, PN EN 60289 | PN EN 60076-1, PN EN 60076-11 | — |
Request a price and lead time
Dry-type earthing transformers 150 kVA to 4 MVA, up to 36 kV, ZNyn11. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What compensation current range is covered?
From 15 A to 300 A, with rated power of 150 kVA to 4 MVA and voltage up to 36 kV.
Can the transformer supply station auxiliaries?
Yes. While there is no earth fault it also supplies the station auxiliaries, with auxiliary power up to 315 kVA.
What are the windings made of?
Copper or aluminium, made by vacuum resin technology or by roving with glass fibre.