BDGO oil-immersed Petersen coil, 150 kVA to 4 MVA, up to 36 kV
The BDGO is an oil-immersed arc-suppression reactor (Petersen coil) that compensates earth-fault current in compensated networks. Rated power 150 kVA to 4 MVA, voltage up to 36 kV, vector group ZNyn11, 50 Hz.
- Type
- Oil-immersed arc-suppression reactor (Petersen coil)
- Series
- BDGO
- Rated power
- 150 kVA to 4 MVA
- Rated voltage
- Up to 36 kV
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
BDGO arc-suppression reactors (Petersen coils) compensate earth-fault current in compensated power networks. Where the windings are star-connected, the reactor is installed between the neutral point of the power transformer and earth.
Where the windings are delta-connected, it is installed between the neutral point of an earthing transformer and earth.
Production range: rated power from 150 kVA to 4 MVA, rated voltage up to 36 kV, vector group ZNyn11. Operating conditions: maximum altitude 1000 m above sea level, ambient temperature from -25 to 40°C, rated frequency 50 Hz.
The core is made of cold-rolled transformer sheet steel with inorganic insulation. The windings use round or profiled wire with lacquer insulation of class H, in copper or aluminium.
The tank is hermetic (without a conservator) or fitted with a conservator, made of sheet steel that is powder coated or hot-dip galvanised. It stands on an undercarriage with wheels whose position can be adjusted to the direction of travel. A radiator tank is also possible.
The reactor is dried and impregnated with transformer oil by the vacuum method. A version to the customer's specification can be made to order.
Technical specifications
| Type | Oil-immersed arc-suppression reactor (Petersen coil) |
|---|---|
| Series | BDGO |
| Rated power | 150 kVA to 4 MVA |
| Rated voltage | Up to 36 kV |
| Vector group | ZNyn11 |
| Rated frequency | 50 Hz |
| Maximum altitude | 1000 m above sea level |
| Ambient temperature | -25 to 40°C |
| Core | Cold-rolled transformer sheet steel, inorganic insulation |
| Windings | Round or profiled wire, class H lacquer insulation, copper or aluminium |
| Tank | Hermetic or with conservator, powder coated or hot-dip galvanised |
How it compares with similar models
| Parameter | BDGO oil-immersed Petersen coil, 150 kVA to 4 MVA, up to 36 kV | BTUZ resin earthing transformer, 150 kVA to 4 MVA, up to 36 kV | Oil-filled earthing transformers 150 kVA to 4 MVA, up to 36 kV, ZNyn11 | Dry-type earthing transformers 150 kVA to 4 MVA, up to 36 kV, ZNyn11 |
|---|---|---|---|---|
| Rated voltage | Up to 36 kV | Up to 36 kV | up to 36 kV | up to 36 kV |
| Rated frequency | 50 Hz | 50 or 60 Hz | 50 Hz | 50 or 60 Hz |
| Core | Cold-rolled transformer sheet steel, inorganic insulation | — | cold-rolled electrical steel with inorganic insulation | cold-rolled electrical steel with inorganic insulation |
| Windings | Round or profiled wire, class H lacquer insulation, copper or aluminium | Copper or aluminium, vacuum or roving technique with glass fibre | round or profiled wire with class H varnish insulation, copper or aluminium | copper or aluminium, vacuum technology or roving with glass fibre |
Request a price and lead time
BDGO oil-immersed Petersen coil, 150 kVA to 4 MVA, up to 36 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Where is a BDGO reactor connected?
Between the neutral point of the power transformer and earth for a star connection, or between the neutral point of an earthing transformer and earth for a delta connection.
What power and voltage range does it cover?
Rated power from 150 kVA to 4 MVA and voltage up to 36 kV, vector group ZNyn11, 50 Hz.
What tank versions are available?
Hermetic without a conservator, or with a conservator, in powder-coated or hot-dip galvanised sheet steel. A radiator tank is also possible.
Similar equipment from other manufacturers