BTUO oil-immersed earthing transformer, Znyn11, 250 kVA to 4 MVA

The BTUO is a three-phase oil-immersed earthing transformer that provides an artificial neutral point on compensated and resistor-earthed networks. Znyn11 windings, 250 kVA to 4 MVA, up to 36 kV.

Type
three-phase oil-immersed earthing transformer
Rated power
250 kVA up to 4 MVA
Rated voltage
up to 36 kV
Vector group
Znyn11

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The BTUO earthing transformer gives compensated and resistor-earthed networks an artificial neutral point. It is a three-phase, oil-immersed unit. While no earth fault is present it also supplies the unit auxiliaries of the substation.

The windings are in a Znyn11 arrangement, which shares current between the phases and cuts the current in a line hit by an earth fault or short circuit. The secondary winding can run continuously at rated conditions, even when the primary carries compensating current.

On a resistor-earthed network the neutral of the unit goes to an earthing resistor, which injects the active component of the current. On a compensated network it is normally paired with an arc-suppression reactor, which adds the reactance needed to extinguish the arc and compensate earth-fault currents.

The core is cold-rolled steel sheet with inorganic insulation. The winding is electrolytic copper wire, enamelled round or profiled, in paper insulation. Voltage adjustment is manual in 5 steps. The tank is steel sheet, powder coated or hot-dip galvanised, and sits on an undercarriage whose wheels can be repositioned.

Standard equipment covers a manual drive for the tap changer, HV and LV porcelain bushings, oil level indicator, rating plate, earth terminals, transport, lifting and pulling lugs, a bi-directional undercarriage and a thermometer pocket. Options are DMCR® or DGPT2 protection relays, connector bushings and heads, surge arresters, terminal clamps for the bushings, vibration dampers under the tank and a thermometer.

The range runs from 250 kVA up to 4 MVA at voltages up to 36 kV. Altitude is limited to 1000 m above sea level, ambient temperature is -25 to 40 °C and frequency is 50 Hz or 60 Hz. Manufacture, testing and tolerances follow PN EN 60076-1 and PN EN 60289. Units with other parameters are agreed individually.

Technical specifications

Typethree-phase oil-immersed earthing transformer
Rated power250 kVA up to 4 MVA
Rated voltageup to 36 kV
Vector groupZnyn11
Voltage adjustment5-step manual
Corecold-rolled steel sheet with inorganic insulation
Windingelectrolytic copper wire, enamelled round or profiled, in paper insulation
Tanksteel sheet, powder coated or hot-dip galvanised, undercarriage with wheels
Rated frequency50 Hz or 60 Hz
Altitudeup to 1000 m above sea level
Ambient temperature-25 to 40 °C
StandardsPN EN 60076-1, PN EN 60289

How it compares with similar models

ParameterBTUO oil-immersed earthing transformer, Znyn11, 250 kVA to 4 MVADry resin reactive power compensation reactor, 150 kVAr to 4 MVArTTDUO oil-immersed arc-suppression transformer-reactor, tap-adjusted, 516 to 3182 kVArTTDUOR oil-immersed arc-suppression transformer-reactor, continuous adjustment, 516 to 3182 kVAr
Typethree-phase oil-immersed earthing transformerdry vacuum-resin reactive power compensation reactorTTDUO oil-immersed arc-suppression transformer-reactor with tap adjustmentTTDUOR oil-immersed arc-suppression transformer-reactor with continuous adjustment
Corecold-rolled steel sheet with inorganic insulationcold-rolled transformer steel with inorganic insulationcold-rolled transformer steel with inorganic insulationcold-rolled transformer steel with inorganic insulation
Tanksteel sheet, powder coated or hot-dip galvanised, undercarriage with wheels—hermetically sealed (no conservator) or with conservator, steel powder coated or hot-dip galvanised; radiator tank also possibleradiator tank with conservator, powder coated with C4 or C5 anti-corrosion system, wheeled undercarriage
Rated frequency50 Hz or 60 Hz50 Hz or 60 Hz50 Hz50 Hz
StandardsPN EN 60076-1, PN EN 60289PN EN 60076-1, PN EN 60076-6PN EN 60076-1, PN EN 60076-6PN EN 60076-1, PN EN 60076-6

Request a price and lead time

BTUO oil-immersed earthing transformer, Znyn11, 250 kVA to 4 MVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the BTUO earthing transformer used for?

It creates an artificial neutral point in compensated and resistor-earthed networks and, in normal operation, supplies the unit auxiliaries.

What is it paired with on compensated and resistor-earthed networks?

On a compensated network it normally works with an arc-suppression reactor; on a resistor-earthed network the neutral goes to an earthing resistor.

What power range and operating conditions apply?

250 kVA to 4 MVA at up to 36 kV, altitude up to 1000 m above sea level, -25 to 40 °C, 50 Hz or 60 Hz.