Dry resin reactive power compensation reactor, 150 kVAr to 4 MVAr
Three-phase dry vacuum-resin reactor for compensating capacitive currents in long cable lines. Rated 150 kVAr to 4 MVAr at up to 36 kV, insulation class F or H.
- Type
- dry vacuum-resin reactive power compensation reactor
- Rated power
- 150 kVAr to 4 MVAr
- Rated voltage
- up to 36 kV
- Cooling
- AN, AF
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Reactor for reactive power compensation in dry vacuum-resin construction, used to offset capacitive currents. The typical case is a long cable line, for example the cable networks of wind farms. The reactor is connected to the network in three phases.
The working parameters can be matched to the required compensating current. On request the reactor gets extra windings to supply the auxiliaries of a substation, switchgear and similar. It can also be fitted with an enclosure of the protection degree the customer specifies.
The core is cold-rolled transformer steel with inorganic insulation and the windings are aluminium or copper. Insulation class is F or H and cooling is AN or AF. PT100 or PTC probes with protection monitor temperature. The standard enclosure rating is IP00; a metal enclosure with a stated IP degree such as IP20, IP21, IP23, IP31, IP33 or IP54 is available on request.
Standard equipment: thermal protection, PT100 sensors, HV terminals on the coils, flat busbar LV terminals, rating plate, wheeled undercarriage, lifting lugs and earthing terminals on the undercarriage. Optional extras are anti-vibration pads, surge arresters, an enclosure and fans.
The range is 150 kVAr to 4 MVAr at voltages up to 36 kV. Altitude is limited to 1000 m above sea level, ambient temperature is -25 to 40 °C and frequency is 50 Hz or 60 Hz. Manufacture, testing and tolerances follow PN EN 60076-1 and PN EN 60076-6. Units with other parameters are agreed individually.
Technical specifications
| Type | dry vacuum-resin reactive power compensation reactor |
|---|---|
| Rated power | 150 kVAr to 4 MVAr |
| Rated voltage | up to 36 kV |
| Cooling | AN, AF |
| Insulation class | F or H |
| Core | cold-rolled transformer steel with inorganic insulation |
| Windings | aluminium or copper |
| Sensors | PT100 or PTC probes with protection |
| Enclosure | IP00 as standard, metal enclosure with specified IP on request (IP20, IP21, IP23, IP31, IP33, IP54 etc.) |
| Rated frequency | 50 Hz or 60 Hz |
| Altitude | up to 1000 m above sea level |
| Ambient temperature | -25 to 40 °C |
| Standards | PN EN 60076-1, PN EN 60076-6 |
How it compares with similar models
| Parameter | Dry resin reactive power compensation reactor, 150 kVAr to 4 MVAr | TDZBK dry coreless reactor for reactive power compensation, 3 to 20 MVAr | TTDUZR dry arc-suppression transformer-reactor, continuous adjustment, 516 to 2273 kVAr | TTDUO oil-immersed arc-suppression transformer-reactor, tap-adjusted, 516 to 3182 kVAr |
|---|---|---|---|---|
| Type | dry vacuum-resin reactive power compensation reactor | dry coreless reactive power compensation reactor TDZBK | TTDUZR dry arc-suppression transformer-reactor with continuous adjustment | TTDUO oil-immersed arc-suppression transformer-reactor with tap adjustment |
| Windings | aluminium or copper | copper or aluminium in resin insulation resistant to UV and weather | round or profiled wire in class H insulation, copper or aluminium | round or profiled wire in class H insulation, copper or aluminium |
| Rated frequency | 50 Hz or 60 Hz | 50 Hz or 60 Hz | 50 Hz | 50 Hz |
Request a price and lead time
Dry resin reactive power compensation reactor, 150 kVAr to 4 MVAr. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Where is this reactor used?
To compensate capacitive currents in long cable lines, for example on wind farms. It is connected to the network in three phases.
Can the reactor supply auxiliaries?
Yes, it can carry additional windings to supply the auxiliaries of a substation, switchgear and similar.
What power and voltage range is covered?
150 kVAr to 4 MVAr at up to 36 kV, with AN or AF cooling and insulation class F or H.