International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Dry resin reactive power compensation reactor, 150 kVAr to 4 MVAr

Three-phase dry vacuum-resin reactor for compensating capacitive currents in long cable lines. Rated 150 kVAr to 4 MVAr at up to 36 kV, insulation class F or H.

Type
dry vacuum-resin reactive power compensation reactor
Rated power
150 kVAr to 4 MVAr
Rated voltage
up to 36 kV
Cooling
AN, AF

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Reactor for reactive power compensation in dry vacuum-resin construction, used to offset capacitive currents. The typical case is a long cable line, for example the cable networks of wind farms. The reactor is connected to the network in three phases.

The working parameters can be matched to the required compensating current. On request the reactor gets extra windings to supply the auxiliaries of a substation, switchgear and similar. It can also be fitted with an enclosure of the protection degree the customer specifies.

The core is cold-rolled transformer steel with inorganic insulation and the windings are aluminium or copper. Insulation class is F or H and cooling is AN or AF. PT100 or PTC probes with protection monitor temperature. The standard enclosure rating is IP00; a metal enclosure with a stated IP degree such as IP20, IP21, IP23, IP31, IP33 or IP54 is available on request.

Standard equipment: thermal protection, PT100 sensors, HV terminals on the coils, flat busbar LV terminals, rating plate, wheeled undercarriage, lifting lugs and earthing terminals on the undercarriage. Optional extras are anti-vibration pads, surge arresters, an enclosure and fans.

The range is 150 kVAr to 4 MVAr at voltages up to 36 kV. Altitude is limited to 1000 m above sea level, ambient temperature is -25 to 40 °C and frequency is 50 Hz or 60 Hz. Manufacture, testing and tolerances follow PN EN 60076-1 and PN EN 60076-6. Units with other parameters are agreed individually.

Technical specifications

Typedry vacuum-resin reactive power compensation reactor
Rated power150 kVAr to 4 MVAr
Rated voltageup to 36 kV
CoolingAN, AF
Insulation classF or H
Corecold-rolled transformer steel with inorganic insulation
Windingsaluminium or copper
SensorsPT100 or PTC probes with protection
EnclosureIP00 as standard, metal enclosure with specified IP on request (IP20, IP21, IP23, IP31, IP33, IP54 etc.)
Rated frequency50 Hz or 60 Hz
Altitudeup to 1000 m above sea level
Ambient temperature-25 to 40 °C
StandardsPN EN 60076-1, PN EN 60076-6

How it compares with similar models

ParameterDry resin reactive power compensation reactor, 150 kVAr to 4 MVArTDZBK dry coreless reactor for reactive power compensation, 3 to 20 MVArTTDUZR dry arc-suppression transformer-reactor, continuous adjustment, 516 to 2273 kVArTTDUO oil-immersed arc-suppression transformer-reactor, tap-adjusted, 516 to 3182 kVAr
Typedry vacuum-resin reactive power compensation reactordry coreless reactive power compensation reactor TDZBKTTDUZR dry arc-suppression transformer-reactor with continuous adjustmentTTDUO oil-immersed arc-suppression transformer-reactor with tap adjustment
Windingsaluminium or coppercopper or aluminium in resin insulation resistant to UV and weatherround or profiled wire in class H insulation, copper or aluminiumround or profiled wire in class H insulation, copper or aluminium
Rated frequency50 Hz or 60 Hz50 Hz or 60 Hz50 Hz50 Hz

Request a price and lead time

Dry resin reactive power compensation reactor, 150 kVAr to 4 MVAr. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Where is this reactor used?

To compensate capacitive currents in long cable lines, for example on wind farms. It is connected to the network in three phases.

Can the reactor supply auxiliaries?

Yes, it can carry additional windings to supply the auxiliaries of a substation, switchgear and similar.

What power and voltage range is covered?

150 kVAr to 4 MVAr at up to 36 kV, with AN or AF cooling and insulation class F or H.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search