TTDUOR oil-immersed arc-suppression transformer-reactor, continuous adjustment, 516 to 3182 kVAr
The TTDUOR combines an earthing transformer, a continuously adjustable arc-suppression reactor and an auxiliary transformer in one oil-immersed unit. Compensation is 516 to 3182 kVAr (60 to 350 A), auxiliary supply 63 to 315 kVA.
- Type
- TTDUOR oil-immersed arc-suppression transformer-reactor with continuous adjustment
- Compensation rating
- 516 kVAr to 3182 kVAr (compensation current 60 A to 350 A)
- Auxiliary supply rating
- 63 kVA to 315 kVA
- Resistor secondary winding
- 500 V, 500 A, 60 s
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The TTDUOR oil-immersed transformer-reactor joins an earthing transformer for the artificial neutral point, a continuously adjustable arc-suppression reactor and a station auxiliary transformer. It holds both a transformer part and a reactor part, so it gives a complete compensated neutral for an MV network. It takes one bay in the substation, where a separate earthing transformer and arc-suppression reactor would take two.
The transformer part has vector group ZNzn0. In an earth fault it spreads the fault current over all phases and lowers its value in the faulted line. With this group the secondary winding can run continuously at rated conditions, even when the primary carries fault current. Bushing leads on the cover connect the transformer part to the reactor part, which adds the reactance needed to extinguish the arc and compensate earth-fault currents. The reactor part has the automatic compensation system BS KKZ or manual control, remote or local.
Compensation rating is 516 kVAr to 3182 kVAr at a compensation current of 60 A to 350 A. The auxiliary supply rating is 63 kVA to 315 kVA. Windings include a resistor secondary of 500 V, 500 A, 60 s (other ratings on request), a measuring winding of 500 V, 100 A, 120 s and an additional winding of 100 V, 3 A, 60 s. Duty is short-time (PK up to 2 h) and rated voltage is up to 36 kV.
The core is cold-rolled transformer steel with inorganic insulation. Windings are round or profiled wire in class H insulation, copper or aluminium. The tank is a radiator tank with a conservator, made of powder-coated steel sheet to the C4 or C5 anti-corrosion system, on an undercarriage whose wheels can be set to the direction of travel.
Standard equipment: porcelain HV bushings to DIN 42531 or EN 50180:2010 or connector bushings, porcelain LV bushings to DIN 42530 or EN 50386:2010, current transformer bushings, oil level indicator, air-gap adjusting drive, Buchholz relay, drain valve to EN 50216-4 or DIN 42551, rating plate, dehydrating breather, contact thermometer, conservator, lifting lugs, earthing terminals, an off-circuit tap changer on the transformer part and the BS KKZ control cabinet. The finish is RAL 7033, other colours on request. Options are a 7-position off-circuit tap changer for the earthing transformer, surge arresters, vibration pads and a protection cable box.
Altitude is limited to 1000 m above sea level, ambient temperature is -25 to 40 °C and frequency is 50 Hz. Manufacture, testing and tolerances follow PN EN 60076-1 and PN EN 60076-6.
Technical specifications
| Type | TTDUOR oil-immersed arc-suppression transformer-reactor with continuous adjustment |
|---|---|
| Compensation rating | 516 kVAr to 3182 kVAr (compensation current 60 A to 350 A) |
| Auxiliary supply rating | 63 kVA to 315 kVA |
| Resistor secondary winding | 500 V, 500 A, 60 s |
| Measuring winding | 500 V, 100 A, 120 s |
| Additional winding | 100 V, 3 A, 60 s |
| Duty | short-time (PK) up to 2 h |
| Rated voltage | up to 36 kV |
| Vector group of the transformer part | ZNzn0 |
| Core | cold-rolled transformer steel with inorganic insulation |
| Windings | round or profiled wire in class H insulation, copper or aluminium |
| Tank | radiator tank with conservator, powder coated with C4 or C5 anti-corrosion system, wheeled undercarriage |
| Compensation control | automatic BS KKZ system or manual (remote or local) |
| Rated frequency | 50 Hz |
| Altitude | up to 1000 m above sea level |
| Ambient temperature | -25 to 40 °C |
| Standards | PN EN 60076-1, PN EN 60076-6 |
How it compares with similar models
| Parameter | TTDUOR oil-immersed arc-suppression transformer-reactor, continuous adjustment, 516 to 3182 kVAr | TTDUZR dry arc-suppression transformer-reactor, continuous adjustment, 516 to 2273 kVAr | TTDUO oil-immersed arc-suppression transformer-reactor, tap-adjusted, 516 to 3182 kVAr | Dry resin reactive power compensation reactor, 150 kVAr to 4 MVAr |
|---|---|---|---|---|
| Type | TTDUOR oil-immersed arc-suppression transformer-reactor with continuous adjustment | TTDUZR dry arc-suppression transformer-reactor with continuous adjustment | TTDUO oil-immersed arc-suppression transformer-reactor with tap adjustment | dry vacuum-resin reactive power compensation reactor |
| Compensation rating | 516 kVAr to 3182 kVAr (compensation current 60 A to 350 A) | 516 kVAr to 2273 kVAr (compensation current 60 A to 250 A) | 516 kVAr to 3182 kVAr (compensation current 60 A to 350 A) | — |
| Auxiliary supply rating | 63 kVA to 315 kVA | 63 kVA to 315 kVA | 63 kVA to 500 kVA | — |
| Windings | round or profiled wire in class H insulation, copper or aluminium | round or profiled wire in class H insulation, copper or aluminium | round or profiled wire in class H insulation, copper or aluminium | aluminium or copper |
| Rated frequency | 50 Hz | 50 Hz | 50 Hz | 50 Hz or 60 Hz |
Request a price and lead time
TTDUOR oil-immersed arc-suppression transformer-reactor, continuous adjustment, 516 to 3182 kVAr. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How does the TTDUOR differ from the TTDUZR?
The TTDUOR is oil-immersed in a radiator tank with a conservator, while the TTDUZR is dry. Both have continuous adjustment of the reactor part and ZNzn0.
What power ranges are available?
Compensation of 516 kVAr to 3182 kVAr (60 A to 350 A), auxiliary supply of 63 kVA to 315 kVA, up to 36 kV.
How is compensation controlled?
Automatically by the BS KKZ system with its control cabinet, or manually, remote or local.