Oil-filled earthing transformers 150 kVA to 4 MVA, up to 36 kV, ZNyn11
Three-phase oil-filled earthing transformers create an artificial neutral point in resistor-earthed and compensated networks. Rated power is 150 kVA to 4 MVA, voltage up to 36 kV, connection group ZNyn11.
- Rated power
- 150 kVA to 4 MVA
- Rated voltage
- up to 36 kV
- Connection group
- ZNyn11
- Max. operating altitude
- 1000 m above sea level
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
An earthing transformer provides an artificial neutral point in networks earthed through a resistor and in compensated networks. These are three-phase transformers which, while there is no earth fault, also supply the station auxiliaries.
The characteristic connection group of an earthing transformer is ZNyn11. In a fault (earth fault) it spreads the fault current across all phases and so reduces its value in the faulty line. The secondary winding can run continuously at rated conditions even when the primary winding carries a compensation current.
In resistor-earthed networks the neutral point of the unit is connected to an earthed resistor that forces the active component. In compensated networks it is normally connected to an arc suppression reactor, which adds the reactance needed to extinguish the arc and compensate earth fault currents.
The production range is 150 kVA to 4 MVA at rated voltage up to 36 kV. Maximum operating altitude is 1000 m above sea level, ambient temperature is from -25 to 40 °C, and rated frequency is 50 Hz. The core is cold-rolled electrical steel with inorganic insulation, and the windings are round or profiled wire with class H varnish insulation, copper or aluminium.
The tank is hermetic (without conservator) or fitted with a conservator, made of powder-painted or hot-dip galvanised sheet steel, on a wheeled chassis whose wheels can be turned to the travel direction. A radiator tank is also possible. Standard fittings include a 5-position manual tap changer drive, porcelain HV bushings to DIN 42531 or EN 50180:2010 and LV bushings to DIN 42530 or EN 50386:2010, an oil level gauge, a thermometer pocket, an oil filler, a drain valve to EN 50216-4 or DIN 42551, and RAL 7033 finish. Options are a 7-position drive, DGPT2 or DMCR2 protection, surge arresters, a dial thermometer, anti-vibration pads and a cable box. Versions with a conservator add a Buchholz relay, an oil level indicator on the conservator, a dehydrating breather and a drain plug. Design, tests and tolerances follow PN EN 60076-1 and PN EN 60289.
Technical specifications
| Rated power | 150 kVA to 4 MVA |
|---|---|
| Rated voltage | up to 36 kV |
| Connection group | ZNyn11 |
| Max. operating altitude | 1000 m above sea level |
| Ambient temperature range | -25 to 40 °C |
| Rated frequency | 50 Hz |
| Core | cold-rolled electrical steel with inorganic insulation |
| Windings | round or profiled wire with class H varnish insulation, copper or aluminium |
| Tank | hermetic (without conservator) or with conservator; radiator tank possible |
| Tap changer | manual drive, 5 positions (7 positions optional) |
| Bushings | porcelain, HV to DIN 42531 or EN 50180:2010, LV to DIN 42530 or EN 50386:2010 |
| Finish colour | RAL 7033 |
| Standards | PN EN 60076-1, PN EN 60289 |
How it compares with similar models
| Parameter | Oil-filled earthing transformers 150 kVA to 4 MVA, up to 36 kV, ZNyn11 | Dry-type earthing transformers 150 kVA to 4 MVA, up to 36 kV, ZNyn11 | Dry arc suppression reactors (Petersen coils) 150 kVAr to 4 MVAr, up to 36 kV | BDGO oil-immersed Petersen coil, 150 kVA to 4 MVA, up to 36 kV |
|---|---|---|---|---|
| Rated power | 150 kVA to 4 MVA | 150 kVA to 4 MVA | 150 kVAr to 4 MVAr | 150 kVA to 4 MVA |
| Rated voltage | up to 36 kV | up to 36 kV | up to 36 kV | Up to 36 kV |
| Rated frequency | 50 Hz | 50 or 60 Hz | 50 Hz | 50 Hz |
| Core | cold-rolled electrical steel with inorganic insulation | cold-rolled electrical steel with inorganic insulation | cold-rolled electrical steel with inorganic insulation | Cold-rolled transformer sheet steel, inorganic insulation |
| Windings | round or profiled wire with class H varnish insulation, copper or aluminium | copper or aluminium, vacuum technology or roving with glass fibre | copper or aluminium, vacuum technology or roving with glass fibre | Round or profiled wire, class H lacquer insulation, copper or aluminium |
| Standards | PN EN 60076-1, PN EN 60289 | PN EN 60076-1, PN EN 60076-11, PN EN 60076-6 | PN EN 60076-1, PN EN 60076-11 | — |
Request a price and lead time
Oil-filled earthing transformers 150 kVA to 4 MVA, up to 36 kV, ZNyn11. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is an oil-filled earthing transformer used for?
It creates an artificial neutral point in resistor-earthed and compensated networks. While there is no earth fault it also supplies the station auxiliaries.
What connection group does it have and why?
ZNyn11. In an earth fault it spreads the fault current across all phases and reduces its value in the faulty line.
Which tank versions are possible?
Hermetic tank without conservator, tank with conservator, or radiator tank. The tank is powder-painted or hot-dip galvanised sheet steel.
Similar equipment from other manufacturers