BDGORs Adjustable Oil-Filled Arc-Suppression Reactor, 546–4850 kVA, up to 21 kV

The BDGORs is an adjustable oil-filled reactor that compensates earth-fault currents automatically on medium voltage networks. It is rated 546 kVA to 4850 kVA for networks up to 21 kV, with a 40-400 A adjustment range.

Rated power
546 kVA to 4850 kVA
Rated network voltage
up to 21 kV
Adjustment range
40-400 A
Rated frequency
50 Hz

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

BDGORs reactors compensate earth-fault currents automatically in medium voltage networks whose neutral is earthed through a reactor. One unit carries out the smooth compensation of these currents and at the same time performs measurement, regulation and AWSCz automation.

The earth-fault parameters of the MV network are found by measuring the currents and voltages produced by a controlled pulse, known as current injection. Adjustment is by an electric drive with manual operation as well, and a control cabinet runs the reactor.

Rated power is 546 kVA to 4850 kVA and rated network voltage is up to 21 kV, with an adjustment range of 40-400 A. Frequency is 50 Hz, maximum altitude is 1000 m above sea level and ambient temperature is -25 to 40 °C. The finish is RAL 7033.

The core is low-loss cold-rolled transformer steel with inorganic insulation. Windings are round enamelled wire of electrolytic copper or profiled wire with paper insulation. The conservator-type tank is powder-painted sheet steel in corrosivity category C5-I (high corrosion resistance), mounted on a wheeled chassis whose wheels can be reset to the direction of travel.

The reactor meets PN-EN 60076-6, PN-EN 60071-1, PN-EN 60071-2 and PN-EN 60529. Standard fittings are porcelain HV bushings to DIN 42531 or EN 50180:2010, LV bushings to DIN 42530 or EN 50386:2010, rating plate, earthing terminals on the chassis, lifting and transport lugs, oil level indicator, contact thermometer, Buchholz relay, dehydrating breather, oil filler and a drain valve to EN 50216-4 or DIN 42551. Connector bushings and anti-vibration pads are optional. Manufacture, testing and tolerances follow PN EN 60076-1 and PN EN 60076-6. Units with other parameters are built by individual agreement.

Technical specifications

Rated power546 kVA to 4850 kVA
Rated network voltageup to 21 kV
Adjustment range40-400 A
Rated frequency50 Hz
Max. operating altitude1000 m above sea level
Ambient temperature range-25 to 40 °C
Corelow-loss cold-rolled transformer steel with inorganic insulation
Windingsround enamelled electrolytic copper wire or profiled wire with paper insulation
Tankwith conservator, powder-painted, corrosivity category C5-I
Adjustment driveelectric and manual
Finish colourRAL 7033

How it compares with similar models

ParameterBDGORs Adjustable Oil-Filled Arc-Suppression Reactor, 546–4850 kVA, up to 21 kVTDOK C Oil-Filled Shunt Compensation Reactor with Cooler, 10–25 MVAr, up to 36 kVTDOK Oil-Immersed Compensation Reactor, 40 kVAr to 10 MVAr, up to 36 kVBWR-b Oil-Filled Resistor for Forcing the Active Component (AWSCz), 20 A
Rated power546 kVA to 4850 kVA10 MVAr – 25 MVAr40 kVAr to 10 MVAr—
Rated frequency50 Hz50 or 60 Hz50 or 60 Hz50 Hz
Corelow-loss cold-rolled transformer steel with inorganic insulationcold-rolled transformer steel with inorganic insulationcold-rolled transformer steel with inorganic insulation—
Windingsround enamelled electrolytic copper wire or profiled wire with paper insulationround or profiled wire with class H insulation, copper or aluminiumcopper—
Tankwith conservator, powder-painted, corrosivity category C5-Iwith oil cooler, powder-painted sheet steel, C4 or C5 anticorrosion systemhermetic (no conservator) or with conservator, powder-painted or hot-dip galvanisedcorrugated, powder-painted sheet steel, corrosivity category C5-I

Request a price and lead time

BDGORs Adjustable Oil-Filled Arc-Suppression Reactor, 546–4850 kVA, up to 21 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the BDGORs reactor used for?

For automatic, smooth compensation of earth-fault currents in medium voltage networks with the neutral earthed through a reactor. It also measures, regulates and provides AWSCz automation.

What are the adjustment range and rating?

The adjustment range is 40-400 A, rated power is 546 kVA to 4850 kVA and network voltage is up to 21 kV.

How does it determine the earth-fault parameters?

It measures the currents and voltages caused by a controlled pulse, called current injection. The MV network parameters are derived from these results.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides