International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

EFFICIENT-REV reversible controlled converters for traction substations

The EFFICIENT-REV reversible controlled converter serves reversible substations (double converters), using thyristors in rectifier mode and IGBTs in inverter mode. Rated DC voltage is 750 V or 1500 V, with efficiency above 99% and above 97%.

Product type
Reversible controlled converter (EFFICIENT-REV)
Rated DC voltage
750 V, 1500 V
Efficiency
above 99% in rectifier mode, above 97% in inverter mode
Overload
Class VI (or other on demand)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The EFFICIENT-REV is a reversible controlled converter for reversible substations, also called double converters. It is based on the design of an air-cooled rectifier equipped with high-overload thyristor blocks, plus force-cooled modular IGBT stacks for energy recovery. It reduces overall energy consumption and is durable and easy to maintain.

Rated DC voltage is 750 V or 1500 V. Thyristor technology is used in rectifier mode and IGBT technology in inverter mode. Efficiency is above 99% in rectifier mode and above 97% in inverter mode. Overload is Class VI, or another class on demand, and the protection degree is up to IP32. Each mode operates independently without affecting the rectifier or inverter mode.

The modular REV converters handle the asymmetrical power flow of traction acceleration and braking while keeping the DC voltage constant within a narrow regulation range. Line voltage regulation offsets voltage drops, which allows the distance between traction substations to be increased.

Reference standards are IEC 60146, IEC 60747, IEC 61000 and EN 50328, plus IEEE ANSI C34.2 and IEEE 519.

The converter recovers waste energy from braking, responds fast, needs little maintenance, gives easy access to all parts and keeps losses minimal. Application is DC traction power supply for railways.

Technical specifications

Product typeReversible controlled converter (EFFICIENT-REV)
Rated DC voltage750 V, 1500 V
Efficiencyabove 99% in rectifier mode, above 97% in inverter mode
OverloadClass VI (or other on demand)
Rectifier modethyristor technology
Inverter modeIGBT technology
Mode operationindependent, without affecting the rectifier or inverter mode
Protection degreeup to IP32
StandardsIEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE ANSI C34.2, IEEE 519

Part numbers

Show all part numbers (1)

REV

How it compares with similar models

ParameterEFFICIENT-REV reversible controlled converters for traction substationsEFFICIENT-REC air cooled rectifiers for DC traction substationsEFFICIENT-INV inverters for regenerative brakingEFFICIENT-BOOST reversible group converters for traction substations
Product typeReversible controlled converter (EFFICIENT-REV)Air cooled traction rectifiers (EFFICIENT-REC)Regenerative braking inverters (EFFICIENT-INV)Reversible group BOOST converters (EFFICIENT-BOOST)
Rated DC voltage750 V, 1500 V750 V, 1500 V, 3000 V750 V, 1500 V, 3000 V—
Protection degreeup to IP32IP2x or IP32up to IP32—
StandardsIEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE ANSI C34.2, IEEE 519IEC 60146-1-1, IEC 60747, EN 50328, IEEE ANSI C34.2IEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE 519IEC 62497 (EN 50124), IEC 60146-1, IEC 60146-2, IEC 62590 (EN 50328), IEC 60850 (EN 50163), IEC 62236 (EN 50121), IEC 60076, IEEE 519

Request a price and lead time

EFFICIENT-REV reversible controlled converters for traction substations. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which technologies are used in rectifier and inverter modes?

Thyristor technology in rectifier mode and IGBT technology in inverter mode.

What efficiency does the converter reach?

Above 99% in rectifier mode and above 97% in inverter mode.

What rated DC voltages are available?

750 V or 1500 V.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides