International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

EFFICIENT-BOOST reversible group converters for traction substations

BOOST technology makes a traction substation fully reversible. An INV-I IGBT inverter on the traction transformer secondaries recovers braking energy and boosts the voltage at the diode rectifier output during acceleration.

Product type
Reversible group BOOST converters (EFFICIENT-BOOST)
Principle
INV-I IGBT inverter on the traction transformer secondaries
During braking
energy recovery to the grid
During acceleration
reactive power injection, boosting AC and DC voltage at the rectifier output

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

BOOST technology is built for fully reversible traction power substations. It uses an IGBT inverter (INV-I) connected to the secondaries of a traction transformer. When energy flows from the DC network during train deceleration, the INV-I recovers it as usual.

During train acceleration, the INV-I injects reactive power into the transformer secondaries and so boosts the AC and DC voltage at the rectifier output. This operating principle allows a diode rectifier to be used, gives complete control over the substation through an energy recovery system, and reuses existing inverter modules designed for energy recovery.

Compared with a thyristor rectifier, the power factor is improved, harmonics are lower and transformer power is reduced. Waste energy from braking is recovered, and voltage control cuts losses in the DC line and raises train speed. Rectifier and inverter modes work independently.

The solution can be installed in existing traction power substations as an upgrade. It increases the distance between substations, improves the power factor in the medium voltage network and reduces both transformer power and no-load voltage in the DC line. It is based on well-known technologies.

Standards complied with are IEC 62497 (EN 50124), IEC 60146-1 (EN 60146-1), IEC 60146-2 (EN 60146-2), IEC 62590 (EN 50328), IEC 60850 (EN 50163), IEC 62236 (EN 50121), IEC 60076 (EN 60076) and IEEE 519. Application is DC traction power supply for railways.

Technical specifications

Product typeReversible group BOOST converters (EFFICIENT-BOOST)
PrincipleINV-I IGBT inverter on the traction transformer secondaries
During brakingenergy recovery to the grid
During accelerationreactive power injection, boosting AC and DC voltage at the rectifier output
Rectifierdiode
Modesrectifier and inverter, independent
Installationupgrade of existing traction power substations possible
StandardsIEC 62497 (EN 50124), IEC 60146-1, IEC 60146-2, IEC 62590 (EN 50328), IEC 60850 (EN 50163), IEC 62236 (EN 50121), IEC 60076, IEEE 519

How it compares with similar models

ParameterEFFICIENT-BOOST reversible group converters for traction substationsEFFICIENT-REV reversible controlled converters for traction substationsEFFICIENT-REC air cooled rectifiers for DC traction substationsEFFICIENT-ESS storage systems for traction substations
Product typeReversible group BOOST converters (EFFICIENT-BOOST)Reversible controlled converter (EFFICIENT-REV)Air cooled traction rectifiers (EFFICIENT-REC)Braking energy storage system (EFFICIENT-ESS)
StandardsIEC 62497 (EN 50124), IEC 60146-1, IEC 60146-2, IEC 62590 (EN 50328), IEC 60850 (EN 50163), IEC 62236 (EN 50121), IEC 60076, IEEE 519IEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE ANSI C34.2, IEEE 519IEC 60146-1-1, IEC 60747, EN 50328, IEEE ANSI C34.2—

Request a price and lead time

EFFICIENT-BOOST reversible group converters for traction substations. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does BOOST work during train acceleration?

The INV-I injects reactive power into the transformer secondaries and boosts the AC and DC voltage at the rectifier output.

Can BOOST be installed in an existing substation?

Yes, it can be installed in existing traction power substations as an upgrade.

What are the advantages over a thyristor rectifier?

Improved power factor, lower harmonics and reduced transformer power.