EFFICIENT-REC air cooled rectifiers for DC traction substations
EFFICIENT-REC naturally air cooled rectifiers for DC traction power supplies, in diode (REC-D) and thyristor controlled (REC-T) versions. Rated DC voltage is 750 V, 1500 V or 3000 V and power is up to 10 MW.
- Product type
- Air cooled traction rectifiers (EFFICIENT-REC)
- Rated DC voltage
- 750 V, 1500 V, 3000 V
- Power
- up to 10 MW
- Overload
- Class VI (or other on demand)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
EFFICIENT-REC rectifiers serve DC traction power supplies and can be built to the customer's specification for all types of traction networks. The air-cooled units are equipped with high-overload, high-blocking-voltage diodes or thyristors. These semiconductor devices are time-tested and dimensioned for high performance, and all rectifier components are fully interchangeable.
Two versions exist. REC-D covers diode rectifiers. REC-T covers thyristor controlled rectifiers, where the controlled variant regulates the line voltage to compensate voltage drops. A cost efficient variant with an integrated isolating switch is available for light rail systems.
Rated DC voltage is 750 V, 1500 V or 3000 V, and power goes up to 10 MW. Overload is Class VI, or another class on demand. Design variants are fixed, drawout or disconnectable, with 6, 12 or 24 pulses. Power connection can be made from the top or the bottom of the cubicle, and the protection degree is IP2x or IP32.
Reference standards are IEC 60146-1-1, IEC 60747 and EN 50328, plus IEEE ANSI C34.2. The range covers all IEC 60146-1-1 configurations.
The rectifiers are compact, with low maintenance, easy access to all parts, long service life and high efficiency. Cooling is natural air.
Technical specifications
| Product type | Air cooled traction rectifiers (EFFICIENT-REC) |
|---|---|
| Rated DC voltage | 750 V, 1500 V, 3000 V |
| Power | up to 10 MW |
| Overload | Class VI (or other on demand) |
| Design variants | fixed, drawout or disconnectable |
| Pulses | 6, 12 or 24 |
| Protection degree | IP2x or IP32 |
| Power connection | from the top or the bottom of the cubicle |
| Cooling | natural air |
| Standards | IEC 60146-1-1, IEC 60747, EN 50328, IEEE ANSI C34.2 |
Part numbers
Show all part numbers (2)
REC-D, REC-T
How it compares with similar models
| Parameter | EFFICIENT-REC air cooled rectifiers for DC traction substations | EFFICIENT-INV inverters for regenerative braking | EFFICIENT-REV reversible controlled converters for traction substations | EFFICIENT-BOOST reversible group converters for traction substations |
|---|---|---|---|---|
| Product type | Air cooled traction rectifiers (EFFICIENT-REC) | Regenerative braking inverters (EFFICIENT-INV) | Reversible controlled converter (EFFICIENT-REV) | Reversible group BOOST converters (EFFICIENT-BOOST) |
| Rated DC voltage | 750 V, 1500 V, 3000 V | 750 V, 1500 V, 3000 V | 750 V, 1500 V | — |
| Protection degree | IP2x or IP32 | up to IP32 | up to IP32 | — |
| Standards | IEC 60146-1-1, IEC 60747, EN 50328, IEEE ANSI C34.2 | IEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE 519 | IEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE ANSI C34.2, IEEE 519 | IEC 62497 (EN 50124), IEC 60146-1, IEC 60146-2, IEC 62590 (EN 50328), IEC 60850 (EN 50163), IEC 62236 (EN 50121), IEC 60076, IEEE 519 |
Request a price and lead time
EFFICIENT-REC air cooled rectifiers for DC traction substations. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How do REC-D and REC-T differ?
REC-D is a diode rectifier. REC-T is thyristor controlled and regulates the line voltage to compensate voltage drops.
What voltage, power and pulse numbers are available?
750 V, 1500 V or 3000 V DC, power up to 10 MW, and 6, 12 or 24 pulses.
What cooling and protection degree do they have?
Natural air cooling and protection degree IP2x or IP32.