EFFICIENT-INV inverters feed braking energy back to the grid. Versions are INV-I (IGBT, air-forced cooling) and INV-T (thyristor, natural air convection), with rated DC voltage of 750 V, 1500 V or 3000 V and power up to 5 MW.

Product type
Regenerative braking inverters (EFFICIENT-INV)
Rated DC voltage
750 V, 1500 V, 3000 V
Power
up to 5 MW
Efficiency
strictly greater than 97.5%

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

EFFICIENT-INV inverters for regenerative braking systems convert waste energy from braking into electricity that is fed back into the grid. The product line was developed around railway requirements: harmonics, reactive power, overload capacity, type of cooling system, maintenance and efficiency.

Two versions exist. INV-I uses IGBT technology with air-forced cooling, and INV-T uses thyristor technology cooled by natural air convection. Rated DC voltage is 750 V, 1500 V or 3000 V and power goes up to 5 MW. Efficiency is strictly greater than 97.5%. Overload is Class VI, or another class on demand, and the protection degree is up to IP32.

Reference standards are IEC 60146, IEC 60747, IEC 61000 and EN 50328, plus IEEE 519.

The inverters help reduce overall energy consumption and are durable and easy to maintain. They reduce heat in tunnels and substations, and no braking resistors are needed on board. Response time is fast, maintenance is low, all parts are easy to reach and losses are minimised.

The manufacturer assists at all stages of a project, from drawing up the specifications to factory acceptance testing of the associated inverter transformer or autotransformer (for connection to an existing rectifier transformer). Applications are DC traction power supply for railways, solar farms, vessels with an on-board DC grid, fuel cells and e-mining truck electrification.

Technical specifications

Product typeRegenerative braking inverters (EFFICIENT-INV)
Rated DC voltage750 V, 1500 V, 3000 V
Powerup to 5 MW
Efficiencystrictly greater than 97.5%
OverloadClass VI (or other on demand)
INV-IIGBT technology, air-forced cooling
INV-Tthyristor technology, natural air convection cooling
Protection degreeup to IP32
StandardsIEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE 519

Part numbers

Show all part numbers (2)

INV-I, INV-T

How it compares with similar models

ParameterEFFICIENT-INV inverters for regenerative brakingEFFICIENT-REC air cooled rectifiers for DC traction substationsEFFICIENT-REV reversible controlled converters for traction substationsEFFICIENT-BOOST reversible group converters for traction substations
Product typeRegenerative braking inverters (EFFICIENT-INV)Air cooled traction rectifiers (EFFICIENT-REC)Reversible controlled converter (EFFICIENT-REV)Reversible group BOOST converters (EFFICIENT-BOOST)
Rated DC voltage750 V, 1500 V, 3000 V750 V, 1500 V, 3000 V750 V, 1500 V—
Protection degreeup to IP32IP2x or IP32up to IP32—
StandardsIEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE 519IEC 60146-1-1, IEC 60747, EN 50328, IEEE ANSI C34.2IEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE ANSI C34.2, IEEE 519IEC 62497 (EN 50124), IEC 60146-1, IEC 60146-2, IEC 62590 (EN 50328), IEC 60850 (EN 50163), IEC 62236 (EN 50121), IEC 60076, IEEE 519

Request a price and lead time

EFFICIENT-INV inverters for regenerative braking. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How do INV-I and INV-T differ?

INV-I uses IGBT technology with air-forced cooling, and INV-T uses thyristors cooled by natural air convection.

What voltage, power and efficiency apply?

750 V, 1500 V or 3000 V DC, power up to 5 MW and efficiency strictly greater than 97.5%.

Are braking resistors needed?

No, no braking resistors are needed on board, because braking energy is fed back into the grid.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides