EFFICIENT-INV inverters for regenerative braking
EFFICIENT-INV inverters feed braking energy back to the grid. Versions are INV-I (IGBT, air-forced cooling) and INV-T (thyristor, natural air convection), with rated DC voltage of 750 V, 1500 V or 3000 V and power up to 5 MW.
- Product type
- Regenerative braking inverters (EFFICIENT-INV)
- Rated DC voltage
- 750 V, 1500 V, 3000 V
- Power
- up to 5 MW
- Efficiency
- strictly greater than 97.5%
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
EFFICIENT-INV inverters for regenerative braking systems convert waste energy from braking into electricity that is fed back into the grid. The product line was developed around railway requirements: harmonics, reactive power, overload capacity, type of cooling system, maintenance and efficiency.
Two versions exist. INV-I uses IGBT technology with air-forced cooling, and INV-T uses thyristor technology cooled by natural air convection. Rated DC voltage is 750 V, 1500 V or 3000 V and power goes up to 5 MW. Efficiency is strictly greater than 97.5%. Overload is Class VI, or another class on demand, and the protection degree is up to IP32.
Reference standards are IEC 60146, IEC 60747, IEC 61000 and EN 50328, plus IEEE 519.
The inverters help reduce overall energy consumption and are durable and easy to maintain. They reduce heat in tunnels and substations, and no braking resistors are needed on board. Response time is fast, maintenance is low, all parts are easy to reach and losses are minimised.
The manufacturer assists at all stages of a project, from drawing up the specifications to factory acceptance testing of the associated inverter transformer or autotransformer (for connection to an existing rectifier transformer). Applications are DC traction power supply for railways, solar farms, vessels with an on-board DC grid, fuel cells and e-mining truck electrification.
Technical specifications
| Product type | Regenerative braking inverters (EFFICIENT-INV) |
|---|---|
| Rated DC voltage | 750 V, 1500 V, 3000 V |
| Power | up to 5 MW |
| Efficiency | strictly greater than 97.5% |
| Overload | Class VI (or other on demand) |
| INV-I | IGBT technology, air-forced cooling |
| INV-T | thyristor technology, natural air convection cooling |
| Protection degree | up to IP32 |
| Standards | IEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE 519 |
Part numbers
Show all part numbers (2)
INV-I, INV-T
How it compares with similar models
| Parameter | EFFICIENT-INV inverters for regenerative braking | EFFICIENT-REC air cooled rectifiers for DC traction substations | EFFICIENT-REV reversible controlled converters for traction substations | EFFICIENT-BOOST reversible group converters for traction substations |
|---|---|---|---|---|
| Product type | Regenerative braking inverters (EFFICIENT-INV) | Air cooled traction rectifiers (EFFICIENT-REC) | Reversible controlled converter (EFFICIENT-REV) | Reversible group BOOST converters (EFFICIENT-BOOST) |
| Rated DC voltage | 750 V, 1500 V, 3000 V | 750 V, 1500 V, 3000 V | 750 V, 1500 V | — |
| Protection degree | up to IP32 | IP2x or IP32 | up to IP32 | — |
| Standards | IEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE 519 | IEC 60146-1-1, IEC 60747, EN 50328, IEEE ANSI C34.2 | IEC 60146, IEC 60747, IEC 61000, EN 50328, IEEE ANSI C34.2, IEEE 519 | IEC 62497 (EN 50124), IEC 60146-1, IEC 60146-2, IEC 62590 (EN 50328), IEC 60850 (EN 50163), IEC 62236 (EN 50121), IEC 60076, IEEE 519 |
Request a price and lead time
EFFICIENT-INV inverters for regenerative braking. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How do INV-I and INV-T differ?
INV-I uses IGBT technology with air-forced cooling, and INV-T uses thyristors cooled by natural air convection.
What voltage, power and efficiency apply?
750 V, 1500 V or 3000 V DC, power up to 5 MW and efficiency strictly greater than 97.5%.
Are braking resistors needed?
No, no braking resistors are needed on board, because braking energy is fed back into the grid.
Similar equipment from other manufacturers