EFFICIENT-AARU automatic assured receptivity units
EFFICIENT-AARU (AARU) units absorb excess regenerative braking energy, remove the need for braking resistors on board and protect against overvoltages. Rated DC voltage is 750 V or 1500 V.
- Product type
- Automatic assured receptivity unit (EFFICIENT-AARU)
- Rated DC voltage
- 750 V, 1500 V
- Rated power
- calculated according to peak load and load duration
- Power balancing
- across the resistors to optimise lifetime
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Automatic assured receptivity units (AARU) meet the railway industry requirements for absorbing excess regenerative braking energy. They eliminate the need for braking resistors on board and protect equipment against overvoltages. A solution can be engineered with the best technology for each need.
Rated DC voltage is 750 V or 1500 V. The rated power of the system is calculated according to peak load and load duration. Power is balanced between the resistors to optimise their lifetime, and all parameters can be set through the local display.
The resistor bank is installed outdoors. The design is easy to maintain, all parts are easy to reach and maintenance is low.
When the network cannot take the energy returned by regenerative braking, the unit absorbs the surplus. This relieves the equipment and limits overvoltages on the DC line.
The manufacturer engineers the unit for the conditions of each line: technology type, power and load profile are agreed at the specification stage. This approach follows railway industry requirements and lets the line take all regenerated energy without braking resistors on the vehicle.
Application is DC traction power supply for railways.
Technical specifications
| Product type | Automatic assured receptivity unit (EFFICIENT-AARU) |
|---|---|
| Rated DC voltage | 750 V, 1500 V |
| Rated power | calculated according to peak load and load duration |
| Power balancing | across the resistors to optimise lifetime |
| Parametrisation | full, through the local display |
| Resistor bank | installed outdoors |
| Protection | against overvoltages |
| Braking resistors on board | not required |
How it compares with similar models
| Parameter | EFFICIENT-AARU automatic assured receptivity units | EFFICIENT-ESS storage systems for traction substations | EFFICIENT-REV reversible controlled converters for traction substations | EFFICIENT-REC air cooled rectifiers for DC traction substations |
|---|---|---|---|---|
| Product type | Automatic assured receptivity unit (EFFICIENT-AARU) | Braking energy storage system (EFFICIENT-ESS) | Reversible controlled converter (EFFICIENT-REV) | Air cooled traction rectifiers (EFFICIENT-REC) |
| Rated DC voltage | 750 V, 1500 V | 750 V, 1500 V | 750 V, 1500 V | 750 V, 1500 V, 3000 V |
Request a price and lead time
EFFICIENT-AARU automatic assured receptivity units. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What does the AARU do?
It absorbs excess regenerative braking energy and protects equipment against overvoltages.
How is the system power determined?
The rated power is calculated according to peak load and load duration.
Where is the resistor bank installed?
Outdoors. No braking resistors are needed on board.
Similar equipment from other manufacturers