International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

LINETRAXX® VME421H voltage and frequency monitoring relay for AC/DC, no separate supply

Multi-functional relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems. It draws its power from the monitored system, so no separate supply is wired. Version D-1 measures AC/DC 0…150 V and version D-2 AC/DC 0…300 V.

Measuring range VME421H-D-1 (r.m.s.)
AC/DC 0…150 V
Measuring range VME421H-D-2 (r.m.s.)
AC/DC 0…300 V
Nominal system voltage D-2
DC 70…300 V / AC 70…300 V, 15…460 Hz
Rated frequency fn
DC, 15…460 Hz

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

For single-phase and DC systems, the LINETRAXX® VME421H monitors undervoltage, overvoltage and frequency. It operates without a separate supply voltage, taking its energy from the monitored system, and has an integrated energy backup. The functions < U, > U, < f and > f can be selected, and response and release delays are adjustable.

Voltage is measured as an r.m.s. value of AC+DC. VME421H-D-1 has a nominal system voltage of DC 9.6…150 V / AC 9.6…150 V and a measuring range of AC/DC 0…150 V. VME421H-D-2 covers DC 70…300 V / AC 70…300 V, 15…460 Hz, with a measuring range of AC/DC 0…300 V. The rated frequency fn is DC, 15…460 Hz, the frequency range 10…500 Hz and the power consumption ≤ 6 VA.

A Preset function sets the parameters automatically. Readings go to an LC display, a fault memory is provided and the operating principle of the relays (N/C or N/O) is selectable. Alarm relays K1 and K2 each have one changeover contact (2 x 1). Electrical endurance is 10000 switching operations, utilisation categories AC-13/AC-14/DC-12/DC-12/DC-12, rated operational voltage 230 V/230 V/24 V/110 V/220 V, rated operational current 5 A/3 A/1 A/0.2 A/0.1 A and minimum contact rating 1 mA at AC/DC ≥ 10 V.

Rated insulation voltage is 250 V, rated impulse voltage 4 kV, overvoltage category III, pollution degree 3 and voltage test 2.21 kV. Standards: IEC 60664-1, IEC 60664-3, IEC 61010-1, IEC 60947-5-1, DIN VDE 0100-430 and IEC 60364-4-43.

The unit measures 93 x 90 x 66.5 mm and fits on a DIN rail or with screws (clip B98060008). Push-wire terminals are B73010003 and B73010004; screw-type terminals are B93010003 and B93010004.

Listed uses are voltage and frequency monitoring of single-phase machines and electrical installations, earth fault monitoring in medium-voltage systems through voltage transformers, monitoring of battery systems, and switching equipment on and off at a certain voltage level.

Technical specifications

Measuring range VME421H-D-1 (r.m.s.)AC/DC 0…150 V
Measuring range VME421H-D-2 (r.m.s.)AC/DC 0…300 V
Nominal system voltage D-2DC 70…300 V / AC 70…300 V, 15…460 Hz
Rated frequency fnDC, 15…460 Hz
Frequency range10…500 Hz
Power consumption≤ 6 VA
Rated insulation voltage250 V
Rated impulse voltage4 kV
Overvoltage categoryIII
Pollution degree3
Number of changeover contacts2 x 1 (K1, K2)
Electrical endurance10000 switching operations
Rated operational voltage230 V/230 V/24 V/110 V/220 V
Rated operational current5 A/3 A/1 A/0.2 A/0.1 A
Dimensions93 x 90 x 66.5 mm

Part numbers

Show all part numbers (5)

B73010003, B93010003, B73010004, B93010004, B98060008

How it compares with similar models

ParameterLINETRAXX® VME421H voltage and frequency monitoring relay for AC/DC, no separate supplyLINETRAXX® VMD421H voltage and frequency monitoring relay, 70…500 VLINETRAXX® VME420 voltage and frequency monitoring relay for AC/DC 0…300 VLINETRAXX® VMD420 voltage and frequency monitoring relay for 3(N)AC up to 500 V
Rated frequency fnDC, 15…460 Hz15…460 HzDC, 15…460 HzDC, 15…460 Hz
Power consumption≤ 6 VA≤ 6 VA≤ 4 VA≤ 4 VA
Rated insulation voltage250 V400 V250 V400 V
Pollution degree3III3III
Dimensions93 x 90 x 66.5 mm93 x 90 x 66.5 mm93 x 70.5 x 45 mm (36 mm width)93 x 70.5 x 74.5 mm

Request a price and lead time

LINETRAXX® VME421H voltage and frequency monitoring relay for AC/DC, no separate supply. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Does the VME421H need a separate supply voltage?

No. It is powered from the monitored system, so no separate supply voltage is required.

How do VME421H-D-1 and VME421H-D-2 differ?

In measuring range, AC/DC 0…150 V for D-1 and AC/DC 0…300 V for D-2, and in nominal system voltage.

Can it be used to monitor batteries?

Yes. Monitoring of battery systems and earth fault monitoring in medium-voltage systems through voltage transformers are listed uses.