LINETRAXX® RCMA420 Type B AC/DC residual current monitor, 10…500 mA
The LINETRAXX® RCMA420 monitors earthed TN and TT systems where smooth DC fault currents can occur. Response range 10…500 mA, 0…2000 Hz, two adjustable response values, an LC display and two changeover alarm relays.
- Response range IΔn
- 10…500 mA
- Frequency range
- 0…2000 Hz
- Supply voltage DC
- 9,6…94 V (RCMA420-D-1) / 70…300 V (RCMA420-D-2)
- Supply voltage AC
- 16…72 V (RCMA420-D-1) / 70…300 V (RCMA420-D-2)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Earthed TN and TT power supplies in which smooth DC fault currents, or residual currents that stay above zero, can occur are the target of the LINETRAXX® RCMA420. It is AC/DC sensitive (Type B to IEC 62020 and IEC/TR 60755) and measures the r.m.s. value of AC plus DC.
External measuring current transformers pick up the current. The response range IΔn is 10…500 mA over 0…2000 Hz. Two separately adjustable response values set the prewarning and the main alarm. An LC display shows the measured value, LEDs indicate status, the transformer connection is monitored and two separate alarm relays each carry one changeover contact (2 x 1). Electrical endurance is 10000 switching operations.
The RCMA420-D-1 is supplied with DC 9,6…94 V / AC 16…72 V and the RCMA420-D-2 with DC 70…300 V / AC 70…300 V, supply frequency DC, 42…460 Hz. Rated insulation voltage is 100 V for the D-1 and 250 V for the D-2, with rated impulse voltage of 2.5 kV and 4 kV respectively. Overvoltage category III, pollution degree 3, power consumption up to 6.5 VA. The device is RoHS compliant.
The enclosure is 36 mm wide and measures 93 x 90 x 70,5 mm. It fits on a DIN rail or is screw mounted with mounting clip B98060008; mounting frame XM420 is B990994. Measuring current transformers CTUB101-CTBC20…60 and connecting cables CTX-100…1000 are listed as options. Typical applications are variable-speed drives, UPS systems, construction site equipment, printing machines, battery systems, laboratory equipment, woodworking machines, MF welding systems and medical electrical equipment.
Technical specifications
| Response range IΔn | 10…500 mA |
|---|---|
| Frequency range | 0…2000 Hz |
| Supply voltage DC | 9,6…94 V (RCMA420-D-1) / 70…300 V (RCMA420-D-2) |
| Supply voltage AC | 16…72 V (RCMA420-D-1) / 70…300 V (RCMA420-D-2) |
| Supply frequency US | DC, 42…460 Hz |
| Rated insulation voltage | 100 V (RCMA420-D-1) / 250 V (RCMA420-D-2) |
| Overvoltage category | III |
| Pollution degree | 3 |
| Rated impulse voltage | 2.5 kV (RCMA420-D-1) / 4 kV (RCMA420-D-2) |
| Power consumption | ≤ 6.5 VA |
| Electrical endurance | 10000 switching operations |
| Enclosure width | 36 mm |
| Dimensions | 93 x 90 x 70,5 mm |
Part numbers
Show all part numbers (4)
B74043001, B94043001, B74043002, B94043002
How it compares with similar models
| Parameter | LINETRAXX® RCMA420 Type B AC/DC residual current monitor, 10…500 mA | LINETRAXX® RCM420 Type A residual current monitor, 10 mA…10 A | LINETRAXX® RCMA423 Type B AC/DC residual current monitor, 30 mA…3 A | LINETRAXX® VME421H voltage and frequency monitoring relay for AC/DC, no separate supply |
|---|---|---|---|---|
| Response range IΔn | 10…500 mA | 10 mA…10 A | 30 mA…3 A | — |
| Frequency range | 0…2000 Hz | 42…2000 Hz | — | 10…500 Hz |
| Rated insulation voltage | 100 V (RCMA420-D-1) / 250 V (RCMA420-D-2) | 100 V (RCM420-D-1); 250 V (RCM420-D-2) | 100 V (RCMA423-D-1), 250 V (RCMA423-D-2) | 250 V |
| Rated impulse voltage | 2.5 kV (RCMA420-D-1) / 4 kV (RCMA420-D-2) | 2,5 kV (RCM420-D-1); 4 kV (RCM420-D-2) | 2.5 kV (RCMA423-D-1), 4 kV (RCMA423-D-2) | 4 kV |
| Power consumption | ≤ 6.5 VA | — | ≤ 6.5 VA | ≤ 6 VA |
| Dimensions | 93 x 90 x 70,5 mm | 93 x 90 x 74,5 mm | 93 x 70.5 x 36 mm | 93 x 90 x 66.5 mm |
Request a price and lead time
LINETRAXX® RCMA420 Type B AC/DC residual current monitor, 10…500 mA. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which systems is the RCMA420 meant for?
Earthed TN and TT systems where smooth DC fault currents can occur. Type B covers both AC and DC components.
What is the response range and how are the thresholds set?
The response range IΔn is 10…500 mA. Two separately adjustable response values set the prewarning and the main alarm.
How do the RCMA420-D-1 and D-2 differ?
By supply voltage: the D-1 takes DC 9,6…94 V / AC 16…72 V, the D-2 DC 70…300 V / AC 70…300 V.